AZA-LAB Classic Open Cup Flash Point Apparatus (AZA – 1294)
- Open cup design for accurate flash point detection
- Complies with ASTM D92 and ISO 2592
- Manual and digital ignition options available
- Designed for petroleum products and lubricants
- Robust stainless-steel construction for durability
- Easy temperature calibration with readable scale
Description
Flash point apparatus is essential equipment in testing laboratories handling petroleum-based products, oils, and flammable liquids. The AZA-LAB Classic Open Cup Flash Point Apparatus is designed to determine the flash point temperature of a sample using the Cleveland Open Cup (COC) method, aligned with ASTM D92 standards.
At its core, a flash point test identifies the lowest temperature at which vapors above a volatile liquid ignite in air when exposed to an ignition source. This value is critical in classifying substances by flammability and assessing their handling, storage, and transportation safety.
The AZA-LAB open cup flash point apparatus includes a high-quality brass test cup supported on a heating block. A thermometer port provides accurate temperature readings, while a manually controlled test flame applicator introduces the ignition source at predetermined intervals during the test. The apparatus includes a thermostatically regulated heating unit, ensuring controlled and consistent temperature rise, per ASTM D92 requirements.
The manual flame application method makes this apparatus ideal for educational purposes, quality control laboratories, and petroleum industry testing environments. The user can observe when the vapor phase ignites, providing reliable results critical for classifying combustible liquids.
The classic design improves usability without compromising safety. The open cup format allows unrestricted vapor expansion, which is more representative of real-world conditions like spills or leaks. The apparatus ensures high reproducibility between tests, even with various operators.Flash Point Apparatus Open Cup helps measure petroleum product volatility. Ideal for labs following ASTM D92 standards. Reliable, accurate & easy to use.flash point apparatus, open cup flash tester, ASTM D92 flash point, petroleum product volatility tester.
🔍 Why Choose AZA-LAB Flash Point Apparatus?
-
ASTM D92 compliant: Ensures global testing standard adherence
-
User-focused design: Intuitive controls and a clear visibility zone for flame detection
-
Accurate heating control: Smooth temperature ramp for reliable results
-
Versatile use: Suitable for heavy oils, lubricants, diesel fuels, and biofuels
-
Cost-effective: Reliable results without investing in high-end automation
Used in oil refineries, transportation safety labs, educational labs, and fuel blending facilities, this apparatus has earned its reputation for performance and affordability.
📘 External Resource Reference: See ASTM D92 full test method guide at www.astm.org/d0092
Specifications:
Parameter | Specification |
---|---|
Test Method | Cleveland Open Cup (ASTM D92) |
Temperature Range | Ambient to 400°C |
Heating Rate | 5–6 °C/min (standard compliant) |
Test Cup Material | Polished Brass |
Ignition Source | Manually controlled test flame |
Thermometer Compatibility | ASTM E2251 glass thermometer |
Power Supply | 230V ±10%, 50/60 Hz |
Dimensions | Approx. 300 × 200 × 220 mm |
Application Areas | Petroleum labs, education, QC testing |
Frequently Asked Questions (FAQ):
Q1: What is the purpose of a flash point test?
A1: It helps determine the lowest temperature at which a liquid can form ignitable vapors. This is critical for flammability classification and safe handling.
Q2: Why is the open cup method used?
A2: The open cup design simulates real-world exposure and is preferred for certain petroleum products, offering more conservative results than closed cup tests.
Q3: Is this apparatus compliant with ASTM standards?
A3: Yes, it is fully compliant with ASTM D92, the standard test method for flash points using the Cleveland Open Cup.
Q4: Can it be used for non-petroleum products?
A4: While optimized for petroleum-based fluids, it can also be used for biodiesel, synthetic oils, and some industrial solvents.
Q5: Does it require special training to operate?
A5: Basic training is sufficient. The unit is easy to use, and the manual ignition method ensures hands-on control during testing.
Additional information
Method Supported |
Open Cup (ASTM D92, ISO 2592) |
---|---|
Sample Cup |
Stainless steel, removable |
Heating Rate |
Adjustable, typically 5–6°C per minute |
Ignition Source |
Manual flame / Electric igniter (optional) |
You may also like…
Semi‑Automated Twin Distillation Analyzer (AZA 1284)
- ASTM D86, D850, D1078, ISO 3405, IP 123, IP 195
Why Choose Semi‑Automated Twin Distillation Analyzer?
- Twin simultaneous distillation boosts laboratory throughput
- Combines semi-automation with manual fine control for flexibility
- Includes comprehensive safety features and PID-regulated temperature control
- Modular accessories allow tailored configurations based on lab needs
3D Printer (AZA 1255)
ABEL CLOSED CUP FLASH POINT TESTER (AZA 1280)
Abrasion Testing Machine for Glazed Tiles (AZA 1262)
ABS Braking System Training Board Simulator (Model AZA1245)
Alternator Trainer (Model AZA1247)
Related products
AutoFlash – Automated Abel Flash Point Analyzer( AZA 1277)
AZA Lab's AutoFlash-1277 is a fully automated, microcontroller-based Abel Flash Point Analyzer designed to accurately determine the flash points of combustible liquids. Conforming to IP 170, ISO 13736, and IS 1448 (P:20) standards, it ensures precise and safe analysis of samples in the temperature range of -30°C to 70°C, extendable up to 110°C.
Equipped with a built-in PC and touchscreen display, the AutoFlash-170 delivers intuitive operation, automated calibration, advanced ignition options, and rapid heating procedures for high-efficiency testing. Ideal for laboratories, petrochemical industries, and quality control applications, this standalone unit streamlines the testing process with enhanced accuracy, safety interlocks, and programmable procedures.
AutoFlash- Automated ABEL Flash Point Analyzer (AZA 1278)
- Model: AutoFlash-1278 Fully automated ABEL Flash Point Analyzer
- Microcontroller-based for precision and reliability
- Complies with IP 170, ISO 13736, IS 1448 (P:20)
- Test range: -30°C to 70°C (extendable to 110°C)
- Ideal for combustible liquids, petroleum QC, and compliance labs
- Suitable for R&D, regulatory testing, and industrial safety analysis
Automated Cleveland Open Cup Flash Point & Fire Point Analyzer(AZA 1276)
- Model: AutoFlash-1276 (v2.0) Fully automated analyzer
- Complies with ASTM D92, ISO 2592, IS 1448 (P:69), IP 36
- Measures flash point and fire point up to 400°C
- Ideal for viscous petroleum products (excluding fuel oils)
- Microcontroller-based system with programmable logic
- Auto ignition, detection, and fire sustain measurement
- Used in QA/QC, R&D labs, refineries, and bitumen testing
Aza Lab Dist‑86S (AZA 1288)
- Semi-automated ASTM D86 distillation unit
- Suitable for gasoline, diesel, solvents & fuels
- PID-controlled heating with uniform temperature
- High-accuracy temperature sensors and digital readout
- Built-in condenser and receiver chamber cooling
- Safety interlocks and over-temp protection
- USB data export for LIMS compatibility
- User-friendly interface with programmable parameters
Dist‑86S Semi‑Automated Distillation Analyzer (AZA 1283)
Flash-92s – Cleveland Open Cup Flash Point Analyzer(AZA 1291)
- Flash Point Analyzer with Cleveland Open Cup method
- Fully compliant with ASTM D92 standards
- Ideal for petroleum, lubricant, and chemical testing
- Precise ignition detection with automatic control
- Safety-enhanced with flame protection and exhaust
- User-friendly touchscreen with real-time data logging
- USB and Ethernet connectivity for LIMS integration
- Compact, durable stainless steel test chamber
Oil & Gas Sampling Cylinders with Double & Triple Ended (AZA -1274 A)
- Model: AZA-1274 A
- Available in single, double, and triple-ended designs
- Manufactured from SS 304 / SS 316 / Monel for corrosion resistance
- Pressure tested and certified (CE, TPED, ISO, DOT)
- Capacity range: 100 cc to 5000 cc
- Max pressure: Up to 3000 psi (206 bar)
- Standard ¼″ or ½″ NPT connections
- Optional dip tubes and custom thread fittings
Programmable Fully‑Automated Cleveland Open‑Cup Flash & Fire Point Analyzer(AZA 1290)
- Fully automated Cleveland Open-Cup flash & fire point tester
- Complies with ASTM D92 and ISO 2592 standards
- Ideal for petroleum, lubricants, and chemical products
- User-friendly touchscreen interface with data logging
- Built-in safety features with auto shutoff
- Programmable heating and ignition cycles
- USB, RS232, and Ethernet ports for easy connectivity
- Compact and durable benchtop design