The AZA 0973 Flakiness Sieve Set is a laboratory-grade toolset used for assessing the flakiness index of coarse aggregates, a critical factor in evaluating the particle shape and performance of construction aggregates in concrete and road layers. Offered by Azalab, this high-quality set enables you to classify and separate flaky particles, ensuring compliance with IS 2386 (Part I) and international standards.
Flaky particles are defined as those whose thickness is less than 0.6 times their mean sieve size. These thin, flat particles tend to affect the strength, compaction, and workability of concrete and bituminous layers. Thus, identifying and controlling their proportion is crucial in infrastructure projects.
🏗️ Importance of Flakiness Index Testing
In aggregate testing, the flakiness index is a vital parameter that influences the behavior of aggregates in structural layers. A high flakiness index reduces:
-
Interlocking strength in concrete
-
Load-bearing capacity in road bases
-
Durability and workability in concrete mixes
Aggregates with excessive flaky particles may lead to weak zones, poor compaction, and increased voids in concrete and asphalt mixes. The AZA 0973 set helps in accurately identifying such materials before use in construction.
- Used to determine flakiness index of coarse aggregates
- Complies with IS 2386 (Part I) standard
- Includes precision slotted gauges for multiple sizes
- Durable stainless steel construction for long life
- Ideal for civil labs and construction QC
Flakiness Sieve Set, AZA 0973, aggregate shape test, flaky particles, IS 2386, Azalab
🔍 Components of the Flakiness Sieve Set
The AZA 0973 Flakiness Sieve Set includes a series of slotted gauges (called flakiness gauges), typically made from durable stainless steel or powder-coated mild steel. Each gauge corresponds to a specific sieve size and slot opening, enabling precise identification of flaky particles based on IS guidelines.
Common slot openings include:
-
63mm × 33.9mm
-
50mm × 26.0mm
-
40mm × 19.5mm
-
31.5mm × 16.0mm
-
25mm × 13.2mm
-
20mm × 10.2mm
-
16mm × 8.5mm
-
12.5mm × 6.7mm
-
10mm × 6.3mm
-
6.3mm × 3.3mm
Each gauge is clearly marked for easy reference and quick testing.
- Used to determine flakiness index of coarse aggregates
- Complies with IS 2386 (Part I) standard
- Includes precision slotted gauges for multiple sizes
- Durable stainless steel construction for long life
- Ideal for civil labs and construction QC
Flakiness Sieve Set, AZA 0973, aggregate shape test, flaky particles, IS 2386, Azalab
🔗 External Resources (Follow Links)
-
IS 2386 (Part I): Methods of Test for Aggregates for Concrete
-
Flakiness Index Test Procedure – The Constructor
-
Importance of Aggregate Shape – Civil Today
🌟 Key Features
-
Comprehensive Gauge Set: Covers all standard sizes
-
Precision Machining: Ensures slot accuracy
-
Durable Finish: Stainless steel or powder-coated for corrosion resistance
-
Portable & Lightweight: Ideal for lab and field use
-
IS Standard Compliant: Manufactured to IS 2386 Part I specifications
- Used to determine flakiness index of coarse aggregates
- Complies with IS 2386 (Part I) standard
- Includes precision slotted gauges for multiple sizes
- Durable stainless steel construction for long life
- Ideal for civil labs and construction QC
Flakiness Sieve Set, AZA 0973, aggregate shape test, flaky particles, IS 2386, Azalab
⚙️ Specifications
Specification | Details |
---|---|
Model | AZA 0973 |
Product Name | Flakiness Sieve Set |
Standard Compliance | IS 2386 (Part I) |
Slot Material | Stainless steel / Powder-coated steel |
Slot Sizes | From 6.3mm to 63mm (as per IS guidelines) |
Use | Flakiness Index Test for Coarse Aggregates |
Accessories Included | Set of slotted gauges, instruction manual |
Weight | ~4–5 kg (varies by set) |
❓ Frequently Asked Questions (FAQ)
Q1: What is the flakiness index?
A1: The flakiness index represents the percentage of flaky particles (thin and flat) in an aggregate sample. It is determined by passing particles through slotted gauges.
Q2: Why is flakiness a problem in construction aggregates?
A2: Flaky aggregates reduce strength, compaction efficiency, and durability of concrete and asphalt.
Q3: Is this set compliant with Indian Standards?
A3: Yes, it complies fully with IS 2386 (Part I) for shape tests of aggregates.
Q4: Can it be used for different aggregate sizes?
A4: Yes, the set includes gauges for a wide range of particle sizes, from 6.3mm to 63mm.
Q5: How is the test performed?
A5: Aggregates retained on standard sieves are checked by passing them through corresponding slots. Those passing through are considered flaky and weighed to calculate the flakiness index.
Related products
AZA 0971 LENGTH GAUGE
AZA 0972 GRID SIEVES
AZA 0974 SHAPE INDEX CALIPER
AZA 0979 SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATES
- Comprehensive apparatus for testing specific gravity and water absorption of aggregates
- Complies with IS 2386 (Part III) & BS 812 standards
- Includes electronic balance, density basket, water tank, and support frame
- Suitable for both fine and coarse aggregate testing
- Essential for quality control in construction and civil engineering projects
AZA 0985 ACCELERATED POLISHING MACHINE
- Tests polish value of aggregates to assess road surface friction
- Conforms to ASTM D3319 and BS 812 standards
- Simulates real-life wear on road aggregates
- Rotating disc with abrasive feed and water spray system
- Suitable for lab-based research, QC, and highway projects
AZA 0988 DIGITAL LOS ANGLES ABRASION TESTING MACHINE
AZA 0989 DORRY ABRASION TESTING MACHINE
- Tests abrasion resistance of coarse aggregates
- Conforms to IS 2386 (Part IV) testing standards
- Ideal for road, railway, and concrete aggregates
- Durable motorized unit with steel disc and weight arm
- Used in quality control and material research labs
- Dorry Abrasion Testing Machine, aggregate wear test, AZA 0989, Azalab