LE CHATELIER FLASK AZA0793
- Used to determine specific gravity of cement
- Conforms to IS 4031 (Part 11) standard
- Calibrated borosilicate glass flask
- 250 ml capacity with graduated neck
- High chemical and thermal resistance
- Ideal for cement labs and testing centers
Description
Le Chatelier Flask AZA0793 is a precision glassware tool used for determining the specific gravity of cement, an essential parameter in cement quality analysis. Available at Azalab, this flask is designed to meet the IS 4031 (Part 11) standard, making it highly suitable for cement testing laboratories, educational institutions, and construction material R&D labs.
Knowing the specific gravity of cement helps assess its density relative to water and detect adulteration, which directly impacts mix designs and strength outcomes in concrete formulations.
Product Overview:
The AZA0793 Le Chatelier Flask is a bulb-shaped flask with a long graduated neck and a funnel-shaped top. It is made from high-grade borosilicate glass for enhanced thermal and chemical resistance. The flask is calibrated for accurate volume measurement and is specifically designed for the displacement method of determining specific gravity.
Features & Design:
- Bulb Volume: Approximately 250 ml
- Graduated Neck: Marked from 0 to 24 ml in 0.1 ml increments
- Funnel Top: Helps in easy pouring of liquid (usually kerosene or naphtha)
- Material: High-quality borosilicate glass
- Accuracy: Each flask is calibrated individually for precision
How It Works:
- The dry Le Chatelier Flask is filled with a reference liquid (kerosene or naphtha) up to a marked graduation.
- A known weight of cement is then gently added.
- The increase in volume observed on the graduated neck indicates the volume of cement displaced.
- Specific gravity is calculated using the known weight and displaced volume.
This test is especially useful in identifying variations in cement composition and helps ensure uniformity and quality control during cement production.
- Used to determine specific gravity of cement
- Conforms to IS 4031 (Part 11) standard
- Calibrated borosilicate glass flask
- 250 ml capacity with graduated neck
- High chemical and thermal resistance
- Ideal for cement labs and testing centers
Applications:
- Cement quality analysis in construction labs
- Academic experiments in civil engineering departments
- Material testing in R&D centers
- Used in conjunction with other cement testing tools like the Le Chatelier Mould and Vicat Apparatus
Compliance:
- IS 4031 (Part 11): Methods of physical tests for hydraulic cement – Part 11: Determination of specific gravity
- Suitable for ASTM equivalent tests with slight procedural adjustments
Why Choose Azalab’s AZA0793?
- Certified precision calibration ensures reliable test results
- Made from durable borosilicate glass for long-lasting performance
- Lightweight and easy to handle during tests
- Supplied with proper packaging to prevent breakage
- Backed by technical support and documentation
For detailed procedural guidance, refer to IS 4031 (Part 11) document.
Explore more cement testing glassware at Azalab’s official website.
 Specifications:
| Parameter | Description |
| Model | AZA0793 |
| Material | Borosilicate glass |
| Volume | 250 ml (bulb) |
| Graduation Range | 0–24 ml (neck), in 0.1 ml increments |
| Standard Compliance | IS 4031 (Part 11) |
| Neck Type | Long neck, calibrated |
| Funnel Top | Yes |
| Use | Cement specific gravity test |
 Frequently Asked Questions (FAQ):
Q1: What is the primary use of the Le Chatelier Flask?
A: It is used to determine the specific gravity of cement by volume displacement method.
Q2: What type of liquid is used in the flask?
A: Usually kerosene or naphtha, which do not react with cement and have stable densities.
Q3: Does this flask meet IS standards?
A: Yes, it conforms to IS 4031 (Part 11) for specific gravity testing of cement.
Q4: Is the flask calibrated?
A: Yes, each flask is individually calibrated for precise measurements.
Q5: Can this be used for other powders?
A: While primarily designed for cement, it can also be used for other fine powders that do not react with the testing liquid.
Additional information
| Model |
AZA 0796 |
|---|---|
| Material |
Borosilicate glass |
| Volume |
250 ml (bulb) |
| Graduation Range |
0–24 ml (neck), in 0.1 ml increments |
| Standard Compliance |
IS 4031 (Part 11) |
Related products
DIGITAL BLAINE AIR PERMEABILITY APPARATUS AZA0798
- Digital model for precise fineness testing
- Measures surface area in cm²/g (1500–6000 range)
- Complies with IS 4031 Part 2 and ASTM C204
- Built-in vacuum pump with digital timer
- Ideal for cement QC, R&D, and educational labs
- Includes calibration certificate & accessories
FULLY AUTOMATIC MORTAR MIXER AZA0805
Built to comply with IS:516, IS:1199, ASTM C192, and other relevant standards, the AZA0805 ensures accurate and reliable mixing performance. Ideal for QA/QC laboratories, construction material testing centers, academic institutions, and R&D facilities, this mixer offers stable operation, high durability, and ease of maintenance.
Laboratory concrete mixer, concrete mixer, AZA0805 mixer, cement testing mixer, concrete testing equipment.
The AZA0805 provides dependable, standardized mixing performance for concrete specimens used in strength testing, durability studies, and trial mix development. Its heavy-duty design, stainless steel drum, and controlled mixing action ensure uniform distribution of aggregates, cement, and water.
This equipment is essential for concrete testing laboratories, cement manufacturers, academic engineering labs, and government material testing centers. It adheres to IS & ASTM standards, ensuring accurate and reproducible mixing suitable for compressive and flexural strength testing.
JOLTING APPARATUS AZA0802
The AZA0802 Jolting Apparatus is a precision-engineered laboratory instrument designed for uniform compaction of cement mortar specimens, ensuring reproducibility and accuracy in strength testing. It plays a vital role in preparing mortar prisms for compressive and flexural strength tests, eliminating air voids and ensuring homogeneous density throughout each specimen.
Manufactured in accordance with IS 10080:1982, and suitable for use under EN 196-1 and ASTM C348 testing standards, the AZA0802 is essential for any laboratory involved in cement quality evaluation, research, or certification.
Whether used in construction QC labs, cement manufacturing units, academic institutions, or R&D centers, the AZA0802 offers dependable, consistent, and safe compaction performance for standardized mortar testing.
Why Compaction Matters in Mortar Testing
The quality and reliability of mortar strength tests depend heavily on the degree of compaction during specimen preparation. Air voids, improper leveling, or inconsistent compaction can lead to inaccurate test values and unreliable performance assessments.
The AZA0802 utilizes a mechanical cam-driven system delivering 60 precise jolts per minute, effectively removing entrapped air from the mortar mix. An inbuilt 60-second automatic timer ensures standard-compliant compaction by stopping the machine after the required number of jolts.
This ensures:
-
Highly consistent mortar density
-
Repeatable strength results
-
Compliance with national and international testing standards
Applications Across Industries
The AZA0802 Jolting Apparatus is widely used in:
-
Cement manufacturing QC laboratories
-
Construction and civil engineering testing labs
-
Educational and training institutes
-
Material certification & calibration laboratories
-
R&D units working on advanced cement products
Key Features & Benefits
-
Standard-Compliant Operation
Conforms fully to IS 10080, EN 196-1, and ASTM C348 for mortar compaction. -
Precise Jolting Mechanism
Delivers 60 calibrated jolts/min, with smooth camshaft motion ensuring uniform compaction. -
Heavy-Duty Mild Steel Frame
Rigid, vibration-resistant structure enhances accuracy and long-term reliability. -
Automatic Timer Control
Pre-set 60-second timer ensures correct compaction cycles without operator intervention. -
Safety Enclosure
Protective guard minimizes risk by shielding moving components during operation. -
Quick-Action Mould Clamping
Secure clamping mechanism designed for 40 × 40 × 160 mm prism moulds. -
Space-Saving Design
Compact, bench-top model ideal for laboratories with limited workspace. -
Low-Maintenance Drive System
Enclosed mechanism requires minimal lubrication and cleaning.
Technical Specifications
| Specification | Details |
|---|---|
| Model | AZA0802 |
| Application | Mortar Prism Compaction |
| Conformity | IS 10080, EN 196-1, ASTM C348 |
| Jolts per Minute | 60 jolts/min (customizable) |
| Timer | 60-sec automatic timer |
| Compatible Mould Size | 40 × 40 × 160 mm |
| Motor Power | 0.25 HP, 230 V AC |
| Construction | Mild steel frame, powder coated |
| Dimensions (L × W × H) | Approx. 500 × 350 × 450 mm |
| Weight | Approx. 35–40 kg |
| Warranty | 1 Year (Manufacturing defects only) |
| Made In | India |
Frequently Asked Questions (FAQ)
Q1: What is the purpose of a jolting apparatus?
It compacts mortar uniformly by applying controlled jolts, removing air pockets and ensuring specimen consistency for strength testing.
Q2: How many jolts does the AZA0802 deliver?
It delivers 60 jolts in one minute, as required by IS 10080. Custom settings are available upon request.
Q3: Which moulds can it be used with?
It is compatible with all standard 40 × 40 × 160 mm mortar prism moulds.
Q4: Is it suitable for educational laboratories?
Yes. Safety guards, controlled operation, and automatic timing make it ideal for use by students under supervision.
Q5: Does it require heavy maintenance?
No. The apparatus has a sealed mechanism requiring minimal lubrication and is easy to clean after each session.
RING MOULD AZA0789
SHRINKAGE BAR MOULD AZA0794
STANDARD SPATULA AZA0801
- Precision Stainless-Steel Blade Flexible, flat, smooth-surfaced steel blade provides accurate mixing and transfer without material loss.
- Ergonomic Wooden or Polypropylene Handle Comfortable, firm grip designed for long-duration laboratory use.
- Corrosion-Resistant Construction High-grade stainless steel ensures resistance to cement paste, admixtures, and moisture.
- Standardized Dimensions Blade geometry and length follow Indian and international testing norms for cement and mortar preparation.
- Versatile Multi-Application Tool Ideal for scraping moulds, leveling surfaces, mixing materials, or handling powders during sample preparation.
- Durable & Easy to Maintain Designed for repeated daily use in demanding laboratory conditions.
- Vicat Consistency Test Assists in accurately transferring cement paste into the Vicat mould.
- Le Chatelier Soundness Test Used to prepare and introduce cement paste into the Le Chatelier mould.
- Setting Time Determination Supports spreading and handling of cement paste during initial and final setting time tests.
- Mortar Strength Testing Facilitates mixing, transferring, and leveling mortar into cube moulds.
- General Laboratory Operations Ideal for dividing dry powders, collecting samples, scraping residue, and routine mixing work.
| Parameter | Specification |
| Model Number | AZA0801 |
| Blade Material | Stainless Steel (corrosion-resistant) |
| Handle Material | Hardwood / Polypropylene |
| Overall Length | 200 – 250 mm (Approx.) |
| Blade Width | 20 – 25 mm |
| Application | Mixing, sampling, scraping |
| Conforms to Standards | IS 269:2015, ASTM C305 |
| Weight | 100 – 150 g (depending on variant) |
TENSILE STRENGTH TESTER (ELECTRICALLY OPERATED) AZA0799
- Electrically operated tensile testing machine
- Tests cement briquette strength up to 1000 kg
- Conforms to IS 4031 (Part 6), ASTM C190
- Sturdy construction with powder-coated finish
- Optional digital load readout version available
- Includes standard specimen holders and accessories