Description
The AZA0797 Laboratory Cement Autoclave is a precision-engineered instrument used to test the soundness of cement by exposing it to high-pressure steam. Ideal for quality control labs, cement factories, and construction research centers, this autoclave is built to ensure consistency and accuracy in testing expansion caused by excess lime in cement.
Available now on Azalab, the AZA0797 helps meet ASTM and IS standard specifications for cement soundness testing. Explore our full range of Cement Testing Equipment
What is Cement Soundness Testing?
Cement soundness refers to the ability of hardened cement paste to retain its volume after setting, without delayed expansion that may cause structural cracking. The autoclave expansion test is a standard method to evaluate this property, especially in Portland cement.
The AZA0797 automates this high-pressure steam testing process, ensuring safe and consistent results.
Learn about this process in our Cement Testing Guide
Key Features
- Model: AZA0797
- Pressure Range: Up to 21 kg/cm² (300 psi)
- Temperature Range: Up to 215°C
- Tank Material: Stainless steel pressure chamber
- Controller: PID digital temperature and pressure control
- Safety: Pressure release valve, timer, and auto cutoff
- Complies with: ASTM C151, IS 4031 (Part 3)
Check out our Lab Autoclaves Collection
Laboratory Cement Autoclave, Cement Autoclave, AZA0797, Cement Testing Equipment, Autoclave for Soundness Test
Applications
Used by:
- Cement Manufacturers
- Civil Engineering Labs
- Construction Quality Control Facilities
- Academic Research Institutions
This autoclave is crucial for identifying unsound cement batches, ensuring the longevity of concrete structures like bridges, dams, and high-rise buildings.
Why Choose Azalab?
Azalab guarantees:
- Tested, certified instruments for lab-grade precision
- Safe packaging with installation support
- Expert calibration and user training available
- Fast shipping and after-sales service
Browse all Construction Material Testing Tools
Related Products
- AZA 0801 Le Chatelier Flask
- AZA 0802 Vicat Needle Apparatus
Specifications
| Feature | Specification |
| Model Number | AZA0797 |
| Application | Soundness Testing of Cement |
| Chamber Material | Stainless Steel (Corrosion-resistant) |
| Working Pressure | Up to 21 kg/cm² (300 psi) |
| Working Temperature | Up to 215°C ± 2°C |
| Chamber Capacity | Suitable for one Le-Chatelier mold with specimen |
| Heating System | Electric heater with thermal cut-off |
| Control Type | Digital PID controller with timer |
| Pressure Gauge | Analog / Digital (Depending on variant) |
| Safety Features | Pressure relief valve, auto cut-off, timer |
| Timer Range | 0–999 minutes |
| Standards Compliance | ASTM C151, IS 4031 (Part 3) |
| Power Supply | 220V ± 10%, 50 Hz, Single Phase |
| Body Finish | Powder-coated mild steel |
| Included Accessories | Le-Chatelier mold, thermometer, measuring scale |
| Dimensions (Approx.) | 450 mm (H) x 250 mm (Dia) |
| Weight | ~20–25 kg |
| Country of Origin | India |
| Warranty | 1 Year Standard Warranty |
FAQ – AZA0797 Laboratory Cement Autoclave
Q1: What is the main purpose of a cement autoclave?
A: It tests the soundness of cement by subjecting it to accelerated steam pressure to measure expansion due to free lime or magnesia.
Q2: Does it include safety features?
A: Yes, the AZA0797 includes a safety release valve, digital PID controller, and automatic pressure cutoff.
Q3: Is it compatible with Indian standards?
A: Yes. It conforms to IS 4031 (Part 3) and ASTM C151.
Q4: How long does a test cycle take?
A: A typical test cycle lasts around 3 hours, including heating, holding, and cooling phases
Additional information
| Model Number |
AZA 0800 |
|---|---|
| Application |
Soundness Testing of Cement |
| Chamber Material |
Stainless Steel (Corrosion-resistant) |
| Working Pressure |
Up to 21 kg/cm² (300 psi) |
| Weight |
~20–25 kg |
| Country of Origin |
India |
| Warranty |
1 Year Standard Warranty |
Related products
APPARATUS FOR REACTIVITY OF QUICKLIME AZA0809
The AZA0809 Quicklime Reactivity Apparatus is a precision laboratory instrument engineered to measure the thermal reactivity of quicklime (CaO) when it reacts with water—a process known as slaking. This exothermic reaction produces heat, and by recording the temperature rise over time, the apparatus helps determine the quality, fineness, and reactivity rate of quicklime.
Widely used in lime processing plants, cement industries, construction materials testing labs, and research institutions, this apparatus ensures accurate evaluation of quicklime performance for applications in soil stabilization, water treatment, chemical manufacturing, and cement additives.
The apparatus fully complies with IS 1514:1990 – Methods of Sampling and Test for Quicklime and Hydrated Lime and ASTM C110 – Standard Test Methods for Physical Testing of Quicklime, Hydrated Lime, and Limestone.
BLAINE’S AIR PERMEABILITY APPARATUS AZA0787
CEMENT SAMPLER AZA0786
GILLMORE NEEDLE APPARATUS AZA0790
PRISM MOULD THREE GANG AZA0803
- Triple-cavity unit for mortar sample casting
- Ideal for compressive/flexural testing
- IS/EN-compliant precision mould
- Lab-grade cast iron build
- Smooth de-moulding and cleaning
TENSILE STRENGTH TESTER (ELECTRICALLY OPERATED) AZA0799
- Electrically operated tensile testing machine
- Tests cement briquette strength up to 1000 kg
- Conforms to IS 4031 (Part 6), ASTM C190
- Sturdy construction with powder-coated finish
- Optional digital load readout version available
- Includes standard specimen holders and accessories
VICAT NEEDLE APPARATUS WITH DASHPOT AZA0788
VOLUME CHANGE APPARATUS AZA0796
- Precision apparatus for measuring soil volume change
- Ideal for CD and CU triaxial testing
- Manual and digital versions available
- Durable lab-grade stainless steel build
- Fully compliant with IS and ASTM standards
- Provided with all necessary accessories
- Backed by Azalab’s quality assurance and support