EARTH RESISTIVITY METER AZA0890
The AZA0890 Earth Resistivity Meter from Azalab is a professional-grade instrument designed for accurate measurement of earth resistance, soil resistivity, and earth voltage. Built in compliance with ASTM G57, this meter is essential for electrical grounding design, geotechnical investigations, safety audits, and installation verification.
Engineered for field reliability, the AZA0890 offers multiple resistance ranges, earth voltage detection, and safety-focused low-current testing—making it suitable for both new installations and live system inspections.
Description
Key Features & Benefits
ASTM G57 Compliant
Designed in accordance with ASTM G57 guidelines for soil resistivity testing, ensuring standardized and dependable results for grounding system design.
Wide Earth Resistance Measurement
Selectable resistance ranges allow precise testing across varying soil and grounding conditions:
-
0–20 Ω
-
0–200 Ω
-
0–2000 Ω
Earth Voltage Measurement
Measures earth voltage up to 200V AC (40–500Hz), enabling users to detect live voltage on grounding systems before resistance testing.
Low Test Current (2mA)
Uses a safe 2mA measuring current, preventing nuisance tripping of ELCBs/RCCBs, even during testing on live installations.
Auto Power-Off
Smart energy-saving function automatically switches the unit off 3–5 minutes after test activation.
Data Hold Function
Allows readings to be frozen on the display for easy recording in field conditions.
Portable & Field-Ready
Compact, lightweight design ensures easy handling and transport in industrial, construction, and remote site environments.
Battery Operated
Operates independently without external power—ideal for on-site testing.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA0890 |
| Standard Compliance | ASTM G57 |
| Earth Resistance Ranges | 0–20Ω / 0–200Ω / 0–2000Ω |
| Earth Voltage Range | 0–200V AC (40–500Hz) |
| Measuring Current | 2mA (ELCB safe) |
| Display | Digital LCD |
| Power Supply | Battery operated |
| Auto Power-Off | Yes (3–5 minutes) |
| Data Hold | Yes |
| Safety Rating | IEC 1010, CAT III 200V |
| Calibration | Factory calibrated with test leads |
| Construction | Compact, lightweight housing |
Applications
-
Soil resistivity measurement (Wenner method)
-
Grounding system design and validation
-
Electrical installation inspection
-
Lightning protection testing
-
Industrial safety audits
-
Power distribution maintenance
-
Telecom and substation grounding checks
Frequently Asked Questions (FAQ)
Q1: What is ASTM G57 used for?
ASTM G57 provides guidance for measuring soil resistivity using standardized methods essential for grounding system design.
Q2: Can AZA0890 be used on live systems?
Yes. The 2mA test current avoids tripping most earth leakage circuit breakers.
Q3: What voltage range can it measure?
It measures AC earth voltage from 0–200V within 40–500Hz.
Q4: Is recalibration required after purchase?
No immediate recalibration is needed. Annual recalibration is recommended for accuracy assurance.
Q5: Are test leads included?
Yes. The unit is supplied with test leads and delivered factory calibrated.
AZA0890 – Accurate, Safe & Standard-Compliant Earth Resistivity Testing
A dependable Azalab solution for professionals demanding precision, safety, and field reliability.
Related products
INFRARED MOISTURE METER AZA0875
The AZA0875 Infrared Moisture Meter from Azalab is a high-precision analytical instrument designed for fast, accurate moisture content determination across a wide range of materials. Utilizing advanced infrared (halogen) heating technology, the AZA0875 significantly reduces analysis time compared to conventional oven-drying methods, delivering reliable results within minutes.
This instrument is ideally suited for geotechnical laboratories, construction quality control, chemical and pharmaceutical industries, food processing, and material testing laboratories, where rapid and repeatable moisture data is essential for process control and compliance.
LIQUID LIMIT DEVICE WITH COUNTER AZA0853
The AZA0853 Liquid Limit Device with Counter from AZALAB is a precision-engineered instrument used for determining the liquid limit of soils in accordance with the Casagrande method. This test is a fundamental component of soil classification and geotechnical investigation, providing critical insight into the plasticity, compressibility, and shear strength of fine-grained soils.
Designed for reliable, repeatable, and standardized testing, the AZA0853 is widely used in geotechnical laboratories, civil engineering departments, construction quality control labs, and academic institutions.
Principle of Liquid Limit Test (Casagrande Method)
The liquid limit is defined as the water content at which soil transitions from a plastic state to a liquid state. In practice, it is determined as the moisture content at which a standard groove cut in the soil sample closes over a length of 12.5 mm under 25 blows of the liquid limit apparatus.
The AZA0853 consists of a polished brass cup mounted on an adjustable bracket. The cup is repeatedly raised and dropped from a fixed height of 1 cm onto a hard rubber base by means of a manually operated cam mechanism. A built-in mechanical counter accurately records the number of blows, ensuring compliance with testing standards and reducing operator error.
METHYLENE BLUE TEST SET AZA0860
- EN 933-9 – Tests for geometrical properties of aggregates (Methylene Blue Test)
- NF P94-068
- UNE 83 180
- UNI 8520-15
- ASTM C837 – Methylene Blue Index of Clay in Fine Aggregate
PROCTOR NEEDLES (SPRING TYPE) AZA0868
- Field assessment of soil compaction
- Estimation of optimum moisture condition
- Subgrade, fill, and trench inspection
- Construction quality control checks
- Geotechnical and educational field investigations
SAND EQUIVALENT TEST SET AZA0859
SOIL CONE PENETROMETER AZA0851
Principle of Operation
A soil paste prepared at a known moisture content is placed in the sample cup. The stainless steel cone, of specified mass and angle, is allowed to penetrate the soil freely for 5 seconds. The depth of penetration (up to 20 mm) is measured using a precision depth gauge. The moisture content corresponding to 20 mm penetration is defined as the liquid limit of the soil.Standards Compliance
- IS 2720 (Part 5) – Determination of liquid and plastic limits
- ASTM D4318 – Liquid Limit, Plastic Limit, and Plasticity Index of Soils
STANDARD COMPACTION TEST AZA0863
VICKSBERG PENTROMETER (PROVING RING TYPE) AZA0870
The Vicksberg Penetrometer (Proving Ring Type) – AZA0870 by Azalab is a precision-engineered field instrument designed to determine the bearing capacity of subgrades, assess soil compaction levels, and conduct rapid shallow soil investigations. It is widely used in road construction, foundation assessment, and infrastructure site inspections where quick, reliable field results are required.
Designed for efficient single-person operation, the instrument incorporates a 100 kg (1 kN) proving ring combined with a high-sensitivity dial gauge of 0.002 mm least count, ensuring accurate and repeatable load measurements. An optical viewer is provided for clear dial visibility, even under bright outdoor conditions, making the unit ideal for on-site testing.
Whether for routine site investigations or quality control of compacted layers, the AZA0870 delivers fast, dependable, and field-ready performance.