Automated Cleveland Open Cup Flash Point & Fire Point Analyzer AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
Description
Precision Flash & Fire Point Determination
Unlike flash-only instruments, the AZA1276 precisely determines both:
-
Flash Point – the lowest temperature at which vapors ignite momentarily
-
Fire Point – the temperature at which combustion is sustained for ≥ 5 seconds
This dual-capability makes the AutoFlash-1276 an essential tool for hazard classification, safety compliance, and product characterization of viscous petroleum materials.
Fully Automated & Standalone Operation
The AZA1276 is a standalone analyzer with an embedded control system, eliminating the need for external computers. Its intuitive LCD / touchscreen interface allows operators to:
-
Select standardized test methods
-
Enter expected flash point values
-
Start automated test cycles with minimal intervention
The system automatically controls heating rate, ignition timing, flame detection, and fire sustain logic, ensuring consistent and reproducible results while reducing operator dependency.
Designed for Viscous Petroleum Products
The Cleveland Open Cup method is particularly suited for high-flash, viscous substances, and the AZA1276 performs exceptionally well with:
-
Lubricating oils and base oils
-
Transformer and insulating oils
-
Bitumen and asphalt materials
-
Greases and waxes
-
Biodiesel and bio-based oils
(Note: Not intended for fuel oils.)
Advanced Safety & Control Features
Safety is integral to the design of the AZA1276. The analyzer includes:
-
Automatic ignition control (electric or gas, interchangeable)
-
Photoelectric flame detection sensor
-
Auto flame suppression and shutdown logic
-
Over-temperature protection and flame shield enclosure
-
Automatic barometric pressure compensation for accurate results
These features make the system suitable for unattended or extended testing cycles in busy laboratory environments.
Applications
-
Flash & fire point testing of viscous petroleum products
-
Quality control in refineries and petrochemical plants
-
Bitumen and asphalt testing laboratories
-
Biodiesel and lubricant compliance testing
-
Hazardous material classification (UN / DOT / GHS)
-
Research & development and academic laboratories
Key Features
-
Fully automated Cleveland Open Cup analyzer
-
Measures flash point and fire point up to 400 °C
-
Fire point detection with ≥ 5-second flame sustain logic
-
Standalone unit with built-in control system
-
Rapid heating with intelligent temperature control
-
Auto search programs for unknown flash points
-
Gas or electric ignition (interchangeable)
-
Automatic pressure correction
-
Robust interlock and safety protection system
Technical Specifications
| Feature | Specification |
|---|---|
| Model | AZA1276 |
| Method | Cleveland Open Cup (COC), Fully Automated |
| Temperature Range | 79 °C to 400 °C |
| Flash Point Detection | Automatic |
| Fire Point Logic | Sustained flame ≥ 5 seconds |
| Standards Compliance | ASTM D92, ISO 2592, IS 1448 (P:69), IP 36 |
| Sample Types | Lubricants, greases, waxes, bitumen, biodiesel |
| Ignition Type | Electric / Gas (auto-controlled) |
| Flame Detection | Photoelectric sensor |
| User Interface | LCD / Touchscreen with programmable parameters |
| Safety Features | Overheat protection, flame shield, auto shutoff |
| Data Output | USB / RS-232 / Built-in printer |
| Power Supply | 230 V AC, 50 Hz |
| Certifications | CE Certified, ISO Compliant |
What’s Included
-
1 × AutoFlash-1276 Analyzer Unit
-
1 × Standard Cleveland Open Cup test cup with cover
-
1 × Electric / Gas ignition module
-
1 × Built-in thermal printer with paper roll
-
1 × Calibration & pressure test certificate
Optional Accessories:
Flame suppression hood, external cooling module
Frequently Asked Questions (FAQ)
Q1: What temperature range does AZA1276 cover?
It accurately measures flash and fire points from 79 °C to 400 °C.
Q2: Does it automatically detect the fire point?
Yes. The system identifies the fire point when combustion sustains for 5 seconds or more.
Q3: Which materials are best suited for this analyzer?
Lubricants, transformer oils, waxes, greases, bitumen, and biodiesel (excluding fuel oils).
Q4: Is the analyzer internationally compliant?
Yes. It complies with ASTM, ISO, IS, and IP standards.
Q5: Can it operate safely with minimal supervision?
Absolutely. Built-in flame detection, suppression, interlocks, and auto shutdown ensure safe operation.
Model: AZA1276 – AutoFlash-1276 Cleveland Open Cup Flash & Fire Point Analyzer
| Function | Details |
|---|---|
| Heating | Coil heater 1000W @ 230 VACHeating rate: 1–20°C/min (user-defined or method-based) |
| Cooling | Centrifugal blower, 56.5 CFM, 35W @ 230 VAC |
| Ignition | Stepper motor-controlled movement7-step Electric Igniter brightness adjustment |
| Arm Movement | Stepper-controlled swing arm with fixed components: sample cup, flash/fire sensors, igniter |
| Flame Extinguisher | Automatic flame suppression after flash/fire point detection |
| Parameter | Specification |
|---|---|
| Auto Calibration | Auto temperature calibration before every test—no external device required |
| Sample Temperature | PT100 Class A, SS Sheath; 0°C to 400°C |
| Bath Temperature | PT100 Class A, Disk Type; 0°C to 500°C |
| Flash Detection | Ionisation ring |
| Fire Detection | Thermal sensor |
| Ambient Pressure | Built-in sensor; 700–1100 hPa (500–800 mmHg) |
Related products
Advanced Triaxial Test System (UU–CU–CD Capable) (AZA 1296)
- UU–CU–CD test modes for complete soil strength profiling
- Automated control of pressure, load, and drainage
- Compatible with clay, silt, sand, and mixed soils
- Integrated data acquisition and real-time graphing
- Meets ASTM D2850, D4767, BS1377, AASHTO standards
- Ideal for geotechnical, research, and academic use
AutoDist‑86 Glass Distillation AZA1282
AutoDist-86 Glass Distillation Unit – AZA1282
The AutoDist-86 Glass Distillation Unit (Model: AZA1282) from AZA Lab is a high-performance laboratory water distiller engineered for the consistent production of ultra-pure distilled water. Manufactured entirely from high-grade borosilicate 3.3 glass, this unit delivers exceptional chemical resistance, thermal stability, and long-term durability, making it ideal for scientific, medical, pharmaceutical, and academic laboratories.
Designed for reliability and purity, the AZA1282 ensures contamination-free distillation without the risk of metallic ion leaching common in metal-bodied stills.
AutoFlash – Automated Abel Flash Point Analyzer AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
Aza Lab Dist‑86S AZA1288
The Distillation Tester AZA1288 from AZA Lab is a high-precision, semi-automated distillation apparatus engineered for accurate determination of the distillation characteristics of petroleum products in full compliance with ASTM D86. Designed for reliability, safety, and operational consistency, the AZA1288 is an essential instrument for quality control laboratories, refineries, fuel testing centers, inspection agencies, and research institutions.
Distillation testing is a critical analytical procedure used to evaluate the boiling range, volatility, and composition of fuels and solvents. These properties directly influence fuel performance, combustion behavior, storage safety, and regulatory classification. The AZA1288 delivers dependable and repeatable results by combining controlled automation with operator oversight, ensuring optimal balance between precision and flexibility.
Cleveland Open-Cup Flash Point Tester AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
Fully Automated Atmospheric Distillation Analyzer AZA1287
The AZA1287 Atmospheric Distillation Analyzer from AZA Lab is a fully automated, high-precision distillation testing system designed for petroleum laboratories that require ASTM D86-compliant determination of boiling range characteristics. Engineered for accuracy, repeatability, and high-throughput operation, the AZA1287 is ideal for testing gasoline, diesel, kerosene, jet fuel, light hydrocarbons, and other petroleum fractions.
Atmospheric distillation testing plays a critical role in evaluating fuel volatility, composition, and performance, directly influencing fuel quality, emissions compliance, and operational safety. The AZA1287 automates the complete distillation process—eliminating manual intervention, reducing operator error, and ensuring consistent, regulation-compliant results.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
TAN & TBN (Karl Fischer Moisture Titrator) Tester AZA1315
The AZA1315 Karl Fischer Moisture Titrator from AZA Lab is a high-precision analytical instrument designed for the determination of trace water content in liquid petroleum products, lubricating oils, additives, and related materials using the Coulometric Karl Fischer method.
The instrument is designed and manufactured in full compliance with international and industry standards including GB/T 7600, SH/T 0246, ASTM D1533, and ASTM D6304, ensuring accurate, repeatable, and globally accepted moisture analysis results.
Powered by advanced microcomputer control technology, the AZA1315 delivers fast testing, high sensitivity, and stable performance. Its touch-screen LCD interface, fully automated titration, and built-in thermal printer make it an ideal solution for laboratories and industrial quality control environments requiring precise moisture determination.