AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
Description
Advanced Automation & Standalone Design
The AutoFlash-1277 is a standalone system equipped with an inbuilt industrial PC and touchscreen display, eliminating the need for external computers. Its intuitive user interface allows operators to configure, execute, and monitor tests with minimal training.
Key automated functions include:
-
Auto temperature calibration before every test
-
Programmable test sequences
-
Automatic detection of unknown flash points
-
Rapid heating control for reduced test cycle time
This high level of automation minimizes operator dependency while maximizing repeatability and laboratory throughput.
High-Precision Measurement & Control
The AZA1277 integrates high-accuracy temperature sensors and intelligent motion control to ensure reliable results:
-
Step-motor controlled test arm and stirrer for consistent sample agitation
-
Thermal flash detection sensor for precise flash point recognition
-
Automatic barometric pressure compensation, correcting results for ambient conditions
-
Rapid heating algorithm to reach expected flash point efficiently without overshoot
Interchangeable gas or electric ignition sources provide flexibility across different lab environments and safety policies.
Safety-Focused Engineering
Designed with operator safety as a priority, the AutoFlash-1277 includes:
-
Multiple built-in safety interlocks
-
Controlled ignition and flame monitoring
-
Enclosed test chamber design
-
Automated shutdown under abnormal conditions
These features make it suitable for continuous use in high-demand quality control and compliance laboratories.
Applications
-
Flash point testing of petroleum products
-
Quality control in refineries and petrochemical plants
-
Fuel and solvent testing laboratories
-
Regulatory and inspection agencies
-
Research & development laboratories
Measurement & Sensor Specifications
| Parameter | Details |
|---|---|
| Model | AZA1277 |
| Flash Point Method | Abel (Closed Cup) |
| Flash Point Range | –30°C to 70°C (extendable up to 110°C) |
| Auto Calibration | Automatic before every run |
| Sample Temperature Sensor | PT100 Class A, SS sheath, –100°C to 150°C |
| Bath Temperature Sensor | PT100 Class A, disk type, –100°C to 200°C |
| Flash Detection | Thermal sensor |
| Ambient Pressure Measurement | Built-in pressure sensor |
| Pressure Range | 700–1100 hPa / 500–800 mmHg |
| Ignition Source | Gas or Electric |
| Operation | Fully automatic, microcontroller-based |
Why Choose AZA1277?
-
High accuracy with full automation
-
Global standards compliance
-
Reduced operator error and fatigue
-
Faster test cycles and higher lab productivity
-
Robust construction for long-term industrial use
Model: AZA1277 – AutoFlash-1277 Abel Flash Point Analyzer by AZA Lab
| Function | Specification |
|---|---|
| Heating/Cooling | Cartridge heater (300W); Cryostat cooling to -30°C (optional) |
| Stirring | Stepper motor controlled, 5–100 RPM user-defined |
| Ignition Source | Electric/Gas igniter with 7-step brightness control, 0.5 to 5°C dip interval |
| Arm Movement | Stepper motor swing arm with integrated cup cover, stirrer, sensors, igniter |
| Fire Detection | Thermal sensor |
| Flame Extinguishing | Auto flame cut-off on fire or flash detection |
-
Temperature sensor (sample/bath) failure
-
Flash detector defect
-
Blown electric igniter
-
Arm not positioned correctly
-
Flash point exceeds selected or 400°C
-
Fire detection triggers alarm & auto shutdown
Related products
ADVANCED TRIAXIAL TEST SYSTEM (UU–CU–CD CAPABLE) AZA1296
The AZA LAB Advanced Triaxial Test System AZA1296 is a fully automated geotechnical laboratory testing system designed for accurate determination of soil shear strength and deformation characteristics under controlled stress and drainage conditions.
The system supports all major triaxial compression testing modes including:
- Unconsolidated Undrained (UU)
- Consolidated Undrained (CU)
- Consolidated Drained (CD)
Engineered for high-precision geotechnical analysis, the AZA1296 replicates in-situ soil stress conditions to evaluate soil stability, strength behavior, pore pressure response, and failure mechanisms under axial loading.
The system integrates servo-controlled loading, automatic pressure regulation, real-time pore pressure monitoring, automated data acquisition, and advanced software analysis, making it ideal for geotechnical laboratories, civil engineering projects, infrastructure development, research institutions, and academic applications.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
CLEVELAND OPEN-CUP FLASH & FIRE POINT TESTER AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
DIST-86S SEMI-AUTOMATED DISTILLATION ANALYZER AZA1283
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
OIL & GAS SAMPLING CYLINDERS – SINGLE END WITH DIP LINE AZA1274
AZA LAB Sampling Cylinders & Gas Sampling Bombs are robust, high‑pressure vessels engineered for safe, reliable collection, storage, and transport of liquids and gases in demanding industrial environments. Available in single‑ended, double‑ended, and flat‑ended variants, they are constructed from premium materials like stainless steel (304/316 L) and Monel, offering corrosion resistance and durable performance . TPED, CE, and ISO certifications ensure compliance with international safety and transport regulations. Each cylinder features precision-engineered NPT connections (¼″ or ½″), customizable volumes from 150 cc to 10 L, and pressure ratings up to 5000 psig, making them ideal for applications in refineries, petrochemical labs, chromatographic analysis, and gas sampling in high‑pressure systems . Hydrostatic testing guarantees reliable integrity under rigorous conditions, while additional options—such as specialized valves, burst discs, dip tubes, and protective carrying cases—allow for tailored configurations to meet specific sampling needs.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.
SEMI-MANUAL DISTILLATION ANALYZER AZA1286
The Semi-Manual Distillation Analyzer (AZA1286) from AZA Lab is engineered to deliver accurate, repeatable, and ASTM D86-compliant atmospheric distillation testing for petroleum products. Designed to combine the robustness of manual operation with the precision of digital instrumentation, the AZA1286 is an ideal solution for educational institutions, QA/QC laboratories, and small- to mid-scale production facilities requiring reliable routine fuel analysis without the complexity of full automation.
This analyzer provides operators with direct control over heating, condensation, and receiver handling, while benefiting from digital temperature measurement, timing functions, and safety monitoring. The result is a cost-effective, dependable system that maintains compliance with international testing requirements.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples