ANILINE POINT TEST APPARATUS AZA1328A
The AZA1328A Aniline Point Test Apparatus is a precision-engineered laboratory instrument designed for the accurate determination of the aniline point of petroleum products, including diesel fuels, lubricating oils, and fuel oils. The aniline point is a critical indicator of the aromatic hydrocarbon content, which directly affects fuel compatibility with rubber components and overall product performance.
Engineered for high accuracy, repeatability, and compliance with international standards, the AZA1328A is ideally suited for petroleum laboratories, refineries, academic institutions, and quality control facilities.
Standard Compliance
- Conforms to: ASTM D611
- Equivalent Standard: IP 2
Description
Working Principle
The apparatus determines the lowest temperature at which equal volumes of aniline and the test sample become completely miscible. The mixture is heated at a controlled rate, and the temperature at which a clear, homogeneous solution is formed is recorded as the aniline point.
Technical Specifications
| Parameter | Specification |
|---|---|
| Temperature Range | Ambient to 150°C |
| Temperature Resolution | 0.1°C |
| Accuracy | ±0.2°C |
| Heating System | Electric heating with regulator |
| Stirring Mechanism | Manual / Motorized (Optional) |
| Bath Medium | Silicone Oil / Glycerin |
| Power Supply | 220–240V AC, 50 Hz |
| Display | Digital / Mercury Thermometer |
| Test Tube | Borosilicate Glass |
Construction Features
- Double-walled oil bath for uniform temperature distribution
- Insulated outer body for enhanced safety and thermal efficiency
- Adjustable heating regulator for precise control
- Durable mild steel body with powder-coated finish
- Transparent viewing window for clear observation of test process
Optional Accessories
- Digital temperature controller
- Magnetic stirrer
- PT100 sensor with digital display
Safety Features
- Over-temperature protection (optional)
- Heat-resistant handles
- Stable and vibration-resistant base
Weight (Approx.)
- 3 – 4 kg
Advantages
- High precision with excellent repeatability
- Simple and reliable operation
- Low maintenance and long operational life
- Suitable for routine and continuous laboratory testing
Related products
CLASSIC OPEN CUP FLASH POINT APPARATUS AZA1294
The AZA LAB Classic Open Cup Flash Point Apparatus AZA1294 is a reliable and cost-effective laboratory instrument designed for accurate determination of flash point temperature of petroleum products and combustible liquids using the Cleveland Open Cup (COC) method.
Manufactured in full compliance with ASTM D92 and ISO 2592 standards, the AZA1294 is ideally suited for petroleum laboratories, quality control facilities, educational institutions, refinery laboratories, and industrial safety testing environments where dependable flash point determination is essential.
The apparatus combines a classic manual testing approach with durable construction, stable heating performance, and straightforward operation, making it an excellent solution for routine laboratory testing, operator training, and quality assurance applications.
CLEVELAND OPEN CUP (D92) FLASH & FIRE POINT TESTER AZA1291
The Cleveland Open Cup Flash Point Tester AZA1291 from AZA Lab is a precision-engineered analytical instrument designed for accurate determination of flash point and fire point of petroleum products in full compliance with ASTM D92 and GB/T 3536-2008 standards. Built for reliability, safety, and intelligent operation, the AZA1291 is ideal for petroleum laboratories, refineries, inspection agencies, and quality control departments requiring repeatable and standards-compliant results.
The analyzer is suitable for samples with flash points ranging from 79°C to 400°C, covering a broad spectrum of petroleum products such as lubricating oils, transformer oils, diesel, heating oils, base oils, waxes, and other high-flash-point materials.
CLEVELAND OPEN-CUP FLASH & FIRE POINT TESTER AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
DIST-86S SEMI-AUTOMATED DISTILLATION TESTER AZA1288
The AZA Lab Dist-86S Semi-Automated Distillation Tester AZA1288 is a precision-engineered petroleum testing instrument designed for accurate determination of the distillation characteristics of petroleum products and volatile organic liquids in full accordance with ASTM D86 standards.
Built for laboratories requiring dependable performance, repeatability, and operational safety, the AZA1288 combines intelligent semi-automation with operator flexibility. The system is ideally suited for petroleum refineries, fuel inspection laboratories, aviation fuel testing facilities, research institutions, petrochemical plants, and educational laboratories.
The instrument utilizes PID-controlled heating technology, precision temperature monitoring, and an integrated condenser cooling system to ensure highly stable distillation conditions and accurate boiling point determination across a wide range of petroleum fractions.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
SEMI-MANUAL DISTILLATION ANALYZER AZA1286
The Semi-Manual Distillation Analyzer (AZA1286) from AZA Lab is engineered to deliver accurate, repeatable, and ASTM D86-compliant atmospheric distillation testing for petroleum products. Designed to combine the robustness of manual operation with the precision of digital instrumentation, the AZA1286 is an ideal solution for educational institutions, QA/QC laboratories, and small- to mid-scale production facilities requiring reliable routine fuel analysis without the complexity of full automation.
This analyzer provides operators with direct control over heating, condensation, and receiver handling, while benefiting from digital temperature measurement, timing functions, and safety monitoring. The result is a cost-effective, dependable system that maintains compliance with international testing requirements.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples