The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.
Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
System Features
Construction
- Borosilicate glass 3.3 throughout
- High resistance to thermal shock and chemical corrosion
- No risk of metallic ion contamination
Heating & Condensation
- Quartz heating element for rapid boiling
- Integrated glass condenser with cooling coil
- Stable distillation and condensation cycle
Functional & Control Specifications
| Function | Specification |
|---|---|
| Operation Mode | Semi-automatic |
| Heating Element | Quartz heater |
| Cooling System | Glass condenser with cooling coil |
| Output Control | Flow regulation valve |
| Monitoring | Visual (transparent glass system) |
Safety & Protection System
| Condition | System Response |
|---|---|
| Low water level | Automatic shut-off via float switch |
| Dry run condition | Heater cut-off |
| Over-temperature | Thermal protection shutdown |
| Abnormal operation | Automatic system stop |
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1282 |
| Product Type | Laboratory Water Distiller |
| Construction Material | Borosilicate Glass 3.3 |
| Distillate Output | 4 L/h (±10%) |
| Power Supply | 230 V AC, 50 Hz |
| Operation | Semi-automatic |
| Safety Features | Float cut-off, thermal protection |
| Dimensions | 550 × 400 × 250 mm |
| Weight | ~9 kg |
What’s Included
- 1 × AZA1282 Glass Distillation Unit
- 1 × Quartz Heating Element
- 1 × Condenser Assembly
- 1 × Support Frame
- 1 × User Manual
Maintenance & Service
- Easy visual inspection due to transparent design
- Simple cleaning and descaling process
- Replaceable heating element
- Recommended periodic descaling for hard water use
Operational Advantages
- Consistent production of high-purity distilled water
- No contamination from metallic components
- Low maintenance and long service life
- Energy-efficient operation
- Suitable for continuous laboratory use
Why Choose AZA1282?
- Reliable and contamination-free water production
- Robust glass construction for longevity
- Integrated safety for unattended operation
- Ideal balance of performance, simplicity, and cost-effectiveness
| Product Name |
Eufy RoboVac G10 Hybrid |
|---|---|
| Model Number |
T2150K11 |
| Cleaning Function |
2-in-1 Vacuum + Mop |
| Navigation |
Smart Dynamic Navigation |
| Suction Power |
Up to 2000Pa |
Related products
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
Standards Compliance
- ASTM D92 (Cleveland Open Cup)
SEDIMENT EXTRACTION TESTER AZA1313
The AZA1313 Sediment Extraction Tester from AZA Lab is a precision laboratory instrument engineered for the accurate determination of sediment content in crude oils and fuel oils using the extraction method specified in ASTM D473. Designed for reliability, consistency, and long-term laboratory use, this tester is an essential tool for petroleum refineries, inspection laboratories, and fuel quality control facilities.
Sediment content is a critical quality parameter that directly impacts storage stability, processing efficiency, pipeline integrity, and combustion performance of petroleum products. The AZA1313 ensures precise sediment measurement by extracting insoluble material using toluene, delivering dependable results across sediment concentrations ranging from 0.01% to 0.40% by mass, with capability for higher concentrations when required.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.
SEMI-MANUAL DISTILLATION ANALYZER AZA1286
The Semi-Manual Distillation Analyzer (AZA1286) from AZA Lab is engineered to deliver accurate, repeatable, and ASTM D86-compliant atmospheric distillation testing for petroleum products. Designed to combine the robustness of manual operation with the precision of digital instrumentation, the AZA1286 is an ideal solution for educational institutions, QA/QC laboratories, and small- to mid-scale production facilities requiring reliable routine fuel analysis without the complexity of full automation.
This analyzer provides operators with direct control over heating, condensation, and receiver handling, while benefiting from digital temperature measurement, timing functions, and safety monitoring. The result is a cost-effective, dependable system that maintains compliance with international testing requirements.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples