SLAKING VESSEL AZA0810

The AZA0810 Slaking Vessel is a specialized laboratory apparatus designed for conducting quicklime reactivity tests by monitoring the temperature rise during the slaking process. This evaluation is essential in cement, lime manufacturing, soil stabilization, and materials laboratories to determine the quality and performance of calcium oxide (CaO) when hydrated.

Constructed from corrosion-resistant stainless steel or anodized aluminum, the vessel features a single or double-walled insulated chamber, ensuring precise temperature measurement without external heat interference. It is engineered in accordance with ASTM C110 – Standard Test Methods for Physical Testing of Quicklime, Hydrated Lime, and Limestone.

Category:
Description

Description

Working Principle

Quicklime reactivity reflects how rapidly and intensely calcium oxide reacts with water. A higher temperature rise indicates higher reactivity and better lime quality.

The AZA0810 Slaking Vessel measures this exothermic temperature rise:

  1. A fixed mass of quicklime (typically 150 g) is placed into the vessel.

  2. A controlled amount of distilled water (approximately 600 mL) at a known starting temperature is added.

  3. A precision thermometer or thermocouple is inserted through the central thermometer port.

  4. The peak temperature and the time required to reach it are recorded.

This helps identify whether a lime sample exhibits low reactivity (slow slaking) or excessively high reactivity (risk of spattering or violent slaking).


Key Features and Benefits

  • ASTM-Compliant: Meets ASTM C110 reactivity test requirements.

  • Thermally Insulated Design: Reduces external heat influence for accurate temperature tracking.

  • Thermometer/Thermocouple Port: Secure, centered holder for precise temperature sensors.

  • Durable Construction: Stainless steel / anodized aluminum for high chemical resistance.

  • Easy Maintenance: Smooth interior surface prevents residue adhesion and simplifies cleaning.

  • Suitable for QC and Research: Used widely in cement labs, lime production units, chemical plants, and soil research applications.


Specifications

Parameter Specification
Model AZA0810
Vessel Material Stainless Steel / Anodized Aluminum
Volume Capacity 1.5 – 2 Liters
Wall Design Single or Double-Walled (Insulated)
Thermometer Port Yes, centered with secure seal
Compatibility Standards ASTM C110
Sample Size 150 g (typical)
Water Volume 600 mL (typical)
Applications Cement labs, lime testing, soil reactivity

Frequently Asked Questions (FAQ)

Q1: What is the AZA0810 Slaking Vessel used for?
It is used to determine the reactivity of quicklime by measuring the temperature rise during hydration.

Q2: Which standard does the apparatus comply with?
It complies with ASTM C110, the standard for physical testing of quicklime and hydrated lime.

Q3: What sample size is required?
Typically 150 g of quicklime and 600 mL of distilled water.

Q4: Can it be used with thermocouples or data loggers?
Yes, the vessel includes a port compatible with thermometers, thermocouples, and digital probes.

Q5: What materials is the vessel made from?
High-grade stainless steel or anodized aluminum, providing durability and resistance to caustic lime.

.

 

Additional information

Additional information

Vessel Material

Stainless Steel / Anodized Aluminum

Volume Capacity

~1.5–2 liters

Wall Design

Single or Double-Walled (insulated)

Thermometer Port

Yes (centered with secure seal)