Petroleum Product Distillation Tester AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
Description
High-Accuracy Manual Distillation System
The AZA1284 is equipped with a two-way front-type structure, allowing one or two samples to be tested simultaneously—even with different test specifications. Each unit operates independently, making it ideal for laboratories handling multiple petroleum products such as gasoline, diesel, kerosene, naphtha, and light distillates.
A special lifting device enables smooth and precise vertical adjustment of the distillation assembly, ensuring accurate positioning and enhanced operator control. The φ12 mm inner-diameter condenser tube provides efficient condensation, stable recovery, and reliable volume measurement throughout the distillation process.
Key Features
Dual-Unit, Independent Operation
-
Simultaneous testing of one or two samples
-
Supports different test conditions on each unit
-
Improves throughput and laboratory efficiency
Independent Control Systems
-
Two separate digital temperature controllers
-
Independent heaters and stirrers
-
Forms two fully independent constant-temperature baths
Uniform & Stable Heating
-
Ensures even temperature distribution
-
Meets ASTM D86 and GB/T 6536 requirements
-
Delivers consistent and reproducible distillation curves
Continuously Adjustable Heating Power
-
Special heating furnace design
-
Smooth power adjustment for different fuel types
-
Safe and reliable operation under varied test conditions
ASTM-Compliant Glassware Compatibility
-
Supports standard distillation flasks, thermometers, and receiving cylinders
-
Suitable for regulatory and quality control testing
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1284 |
| Power Supply | AC 220V ±10%, 50 Hz |
| Total Power Consumption | ≤ 4000 W |
| Receiving Cylinder | 100 mL, 1 mL graduation |
| Distillation Flask | 125 mL, compliant with ASTM D86 & GB/T 6536 |
| Thermometer Range | –2 to 300°C and –2 to 400°C |
| Thermometer Division | 1°C |
| Flask Support Board | SIC, bore diameters φ32 mm, φ38 mm, φ50 mm |
| Temperature Controller Range | Ambient +10°C to 60°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Display | LED |
| Ambient Temperature | 15 – 35°C |
| Relative Humidity | ≤ 85% |
| Overall Dimensions (L×W×H) | 760 × 520 × 500 mm |
| Net Weight | 40 kg |
Applications
-
Petroleum Testing Laboratories
Determination of distillation characteristics of gasoline, diesel, kerosene, and light petroleum fractions. -
Quality Control & Inspection Units
Routine compliance testing according to ASTM D86 and GB/T 6536 standards. -
Refineries & Fuel Blending Facilities
Monitoring fuel volatility and batch consistency. -
Research & Academic Laboratories
Manual distillation studies with precise operator control.
Why Choose AZA1284
-
Dual-unit design for higher testing efficiency
-
Independent digital control for precise, repeatable results
-
ASTM D86 and GB/T 6536 compliant construction
-
Safe, adjustable heating for diverse petroleum products
-
Durable, laboratory-grade design for long-term use
Model: AZA1284 – Manual Distillation Unit
Related products
Apparatus for Hydrogen Sulfide Tester – AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314Â from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an Hâ‚‚S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
AutoFlash – Automated Abel Flash Point Analyzer AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
The Automated Cleveland Open Cup Flash Point Analyzer (Model: AZA1279) from AZA Lab is a fully automated, microprocessor-controlled flash point testing system designed for accurate determination of the flash point of petroleum products using the Cleveland Open Cup (COC) method. Engineered in strict compliance with ASTM D92, the AZA1279 delivers reliable, repeatable, and traceable results for laboratories where safety, regulatory compliance, and precision are essential.
Flash point determination plays a vital role in assessing the flammability, handling safety, storage conditions, and transportation classification of combustible liquids. The AZA1279 automates the entire test cycle—heating, ignition, detection, and result recording—minimizing human error while maximizing consistency and operator safety
AZA LAB Classic Open Cup Flash Point Apparatus AZA1294
The AZA1294 Classic Open Cup Flash Point Apparatus from AZA LAB is a reliable and cost-effective laboratory instrument designed for the determination of flash point temperature of petroleum products and flammable liquids using the Cleveland Open Cup (COC) method, in full compliance with ASTM D92 and ISO 2592 standards.
This apparatus is widely used in petroleum testing laboratories, quality control facilities, educational institutions, and fuel safety assessment centers, where accurate flammability classification is essential.
Cleveland Open-Cup Flash Point Tester AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
TAN & TBN (Karl Fischer Moisture Titrator) Tester AZA1315
The AZA1315 Karl Fischer Moisture Titrator from AZA Lab is a high-precision analytical instrument designed for the determination of trace water content in liquid petroleum products, lubricating oils, additives, and related materials using the Coulometric Karl Fischer method.
The instrument is designed and manufactured in full compliance with international and industry standards including GB/T 7600, SH/T 0246, ASTM D1533, and ASTM D6304, ensuring accurate, repeatable, and globally accepted moisture analysis results.
Powered by advanced microcomputer control technology, the AZA1315 delivers fast testing, high sensitivity, and stable performance. Its touch-screen LCD interface, fully automated titration, and built-in thermal printer make it an ideal solution for laboratories and industrial quality control environments requiring precise moisture determination.
