TAN & TBN (KARL FISCHER MOISTURE TITRATOR) TESTER AZA1315
The AZA1315 Karl Fischer Moisture Titrator from AZA Lab is a high-precision analytical instrument designed for the determination of trace water content in liquid petroleum products, lubricating oils, additives, and related materials using the Coulometric Karl Fischer method.
The instrument is designed and manufactured in full compliance with international and industry standards including GB/T 7600, SH/T 0246, ASTM D1533, and ASTM D6304, ensuring accurate, repeatable, and globally accepted moisture analysis results.
Powered by advanced microcomputer control technology, the AZA1315 delivers fast testing, high sensitivity, and stable performance. Its touch-screen LCD interface, fully automated titration, and built-in thermal printer make it an ideal solution for laboratories and industrial quality control environments requiring precise moisture determination.
Description
Key Features & Applications
High Sensitivity Analysis
-
Ideal for micro and trace-level water content determination
-
Suitable for low-moisture petroleum products and additives
Precise Calibration
-
Equipped with a 0.5 µL precision injector for fast and accurate calibration
Stable & Accurate Measurement
-
Utilizes alternating balance isolation detection technology
-
Ensures fast response, excellent repeatability, and reliable results
User-Friendly Operation
-
7-inch color LCD touch screen
-
Menu-driven interface for intuitive operation and minimal training
Efficient Data Output
-
Built-in printer for fast, clear, and quiet result printing
Programmable Mixing Control
-
Mixing speed can be adjusted directly on-screen
-
Ensures optimal reaction conditions for different sample types
Applications
-
Moisture determination in petroleum products
-
Analysis of lubricating oils and additives
-
Quality control in refineries and blending plants
-
Research and testing laboratories
-
Industrial and regulatory inspection labs
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1315 |
| Titration Method | Microprocessor-controlled coulometric titration |
| Electrolytic Current Output | 0–400 mA, automatic control |
| Display System | 7-inch color LCD touch screen |
| User Interface | Touch screen input |
| Sensitive Valve Resolution | 0.1 µg H₂O |
| Accuracy | 10 µg – 1 mg H₂O: ±3 µg |
| Above 1 mg H₂O: ±0.3% (excluding injection error) | |
| Power Consumption | < 100 W |
| Operating Environment | Free from vibration, strong magnetic fields, dust, or corrosive gases |
Why Choose AZA1315
-
Accurate and rapid moisture determination using coulometric KF method
-
Fully compliant with ASTM, GB, and SH standards
-
Touch-screen controlled, fully automated operation
-
Integrated printer for immediate documentation
-
Compact, stable, and reliable for long-term laboratory use
Model: AZA1315 – Karl Fischer Moisture Titrator
Related products
APPARATUS FOR HYDROGEN SULFIDE TESTER AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314Â from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an Hâ‚‚S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
CLEVELAND OPEN CUP (D92) FLASH & FIRE POINT TESTER AZA1291
The Cleveland Open Cup Flash Point Tester AZA1291 from AZA Lab is a precision-engineered analytical instrument designed for accurate determination of flash point and fire point of petroleum products in full compliance with ASTM D92 and GB/T 3536-2008 standards. Built for reliability, safety, and intelligent operation, the AZA1291 is ideal for petroleum laboratories, refineries, inspection agencies, and quality control departments requiring repeatable and standards-compliant results.
The analyzer is suitable for samples with flash points ranging from 79°C to 400°C, covering a broad spectrum of petroleum products such as lubricating oils, transformer oils, diesel, heating oils, base oils, waxes, and other high-flash-point materials.
FULLY AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1287
The AZA1287 Atmospheric Distillation Analyzer from AZA Lab is a fully automated, high-precision distillation testing system designed for petroleum laboratories that require ASTM D86-compliant determination of boiling range characteristics. Engineered for accuracy, repeatability, and high-throughput operation, the AZA1287 is ideal for testing gasoline, diesel, kerosene, jet fuel, light hydrocarbons, and other petroleum fractions.
Atmospheric distillation testing plays a critical role in evaluating fuel volatility, composition, and performance, directly influencing fuel quality, emissions compliance, and operational safety. The AZA1287 automates the complete distillation process—eliminating manual intervention, reducing operator error, and ensuring consistent, regulation-compliant results.
PETROLEUM PRODUCT DISTILLATION TESTER AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
PRECISION AUTOMATED DISTILLATION ANALYZER AZA1281
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
PROGRAMMABLE FULLY-AUTOMATED CLEVELAND OPEN-CUP FLASH & FIRE POINT ANALYZER AZA1290
The AZA Lab Programmable Fully-Automated Cleveland Open-Cup Flash & Fire Point Analyzer AZA1290 is a high-precision petroleum testing instrument designed for fully automated determination of flash and fire points of petroleum products, lubricants, oils, bituminous materials, and combustible liquids in accordance with ASTM D92 and ISO 2592 standards.
Engineered for modern petroleum laboratories, the AZA1290 combines intelligent automation, advanced safety systems, precision temperature control, and comprehensive data management to deliver highly repeatable and operator-independent test results.
The system automates the complete testing cycle including heating control, ignition application, flash detection, fire point detection, result recording, and emergency shutdown, significantly improving laboratory efficiency, testing consistency, and operational safety.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
