SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
Description
Reliable Flash & Fire Point Determination
The flash point represents the lowest temperature at which vapors ignite momentarily when exposed to an ignition source, while the fire point indicates sustained combustion. These parameters are critical for evaluating fire hazards, storage safety, transportation compliance, and product classification.
AZA1289 utilizes a semi-automated ignition and detection system, reducing operator dependency while maintaining flexibility during test setup. The analyzer automatically applies the ignition source at programmed temperature intervals, while a sensitive flame detection system identifies flash and fire points with high accuracy.
Key Features
ASTM D92 & ISO 2592 Compliance
-
Fully conforms to Cleveland Open Cup (COC) test requirements
-
Suitable for regulatory, contractual, and quality assurance testing
Semi-Automated Operation
-
Automated ignition and flash detection
-
Manual sample cup placement for controlled operation
-
Ideal for medium- to high-throughput laboratories
Uniform Heating System
-
Thermostatically controlled aluminum heating block
-
Ensures stable and uniform temperature ramp as per ASTM protocol
Digital Control & Monitoring
-
Digital temperature display with high-accuracy thermocouple
-
Programmable heating rate and ignition timing
-
Automatic test termination upon flash detection
Robust & Safe Design
-
Stainless steel sample cup (75 ml), corrosion resistant and easy to clean
-
Over-temperature protection and ignition shielding
-
Gas cut-off and temperature limiter for enhanced safety
Compact Benchtop Configuration
-
Space-saving design suitable for standard laboratory benches
-
Low maintenance and long service life
Typical Applications
-
Petroleum Refineries
-
Lubricant Manufacturing Plants
-
Fuel Quality Control Laboratories
-
Chemical & Solvent Testing Facilities
-
Fire & Transport Safety Departments
-
Academic & Industrial R&D Laboratories
Technical Specifications
| Feature | Specification |
|---|---|
| Model | AZA1289 |
| Test Method | Cleveland Open Cup (ASTM D92, ISO 2592) |
| Flash Point Range | Ambient to 400°C |
| Fire Point Detection | Yes |
| Sample Cup Capacity | 75 ml |
| Heating Rate | Programmable, ASTM D92 compliant |
| Ignition Source | Electric or gas, automatic |
| Temperature Measurement | Digital display with thermocouple |
| Safety Systems | Over-temperature shutoff, ignition shield |
| Power Supply | 230V AC, 50/60 Hz |
| Dimensions (W × D × H) | 320 × 380 × 400 mm |
| Net Weight | 13 kg |
Why Choose AZA1289
-
Proven ASTM D92 compliant performance
-
Improved accuracy over manual COC testers
-
Reduced operator error with semi-automation
-
Cost-effective alternative to fully automated systems
-
Durable construction for long-term laboratory use
Frequently Asked Questions (FAQ)
Q1: What makes AZA1289 semi-automated?
Heating and ignition are automated, while sample placement and cup handling remain manual, offering flexibility with improved accuracy.
Q2: Is it suitable for high flash point products?
Yes. It is designed for materials with flash points above 79°C, including oils, lubricants, and fuels.
Q3: Does it comply with international standards?
Yes. AZA1289 fully complies with ASTM D92 and ISO 2592.
Q4: How does it differ from a manual COC tester?
Unlike manual units, AZA1289 features automatic ignition, programmable heating, and digital temperature monitoring, improving safety and repeatability.
Q5: Is it suitable for routine QC testing?
Absolutely. It is ideal for daily quality control, compliance testing, and safety evaluation.
Model: AZA1289 – Semi-Automated Cleveland Open Cup Flash Point Analyzer
Additional information
| Test Method |
Cleveland Open-Cup (ASTM D92) |
|---|---|
| Flash Point Range |
Ambient to 400°C |
| Fire Point Detection |
Yes |
| Sample Cup Capacity |
75 ml |
-
Automated operation with an 8.4″ touchscreen, easy one-click start, and audible alerts on completion
-
Rapid heating modes: Standard, rapid, or user-defined rates (1–20 °C/min)
-
Versatile ignition: Switch easily between gas or electric igniter sources
-
Unknown sample detection: Built-in “search” mode to automatically locate flash point in unmarked samples
-
Safety & precision: Automatic barometric pressure correction and comprehensive interlocks ensure reliable operation
-
Power: 230 VAC, 50 Hz, 1.5 kW
-
Heating: 1000 W coil heater (230 V) with precise thermal profiling
-
Cooling: Integrated centrifugal blower (56.5 CFM) for rapid cooldown
-
Measurement: PT100 Class A sensors on sample (0–400 °C) and bath (0–500 °C); ionization ring flash detection; ambient pressure range: 700–1100 hPa
-
Dimensions & Weight: W 410 × D 420 × H 330 mm; approx. 16 kg
-
Environmental: Operational in 10–35 °C at ≤80% RH
You may also like…
ADVANCED TRIAXIAL TEST SYSTEM (UU–CU–CD CAPABLE) AZA1296
The AZA LAB Advanced Triaxial Test System AZA1296 is a fully automated geotechnical laboratory testing system designed for accurate determination of soil shear strength and deformation characteristics under controlled stress and drainage conditions.
The system supports all major triaxial compression testing modes including:
- Unconsolidated Undrained (UU)
- Consolidated Undrained (CU)
- Consolidated Drained (CD)
Engineered for high-precision geotechnical analysis, the AZA1296 replicates in-situ soil stress conditions to evaluate soil stability, strength behavior, pore pressure response, and failure mechanisms under axial loading.
The system integrates servo-controlled loading, automatic pressure regulation, real-time pore pressure monitoring, automated data acquisition, and advanced software analysis, making it ideal for geotechnical laboratories, civil engineering projects, infrastructure development, research institutions, and academic applications.
AIR BAG TRAINER AZA1246
The AZA1246 AZALAB Air Bag Trainer is a comprehensive educational training platform designed to demonstrate the structure, operation, diagnostics, and fault analysis of modern automotive airbag systems, also known as Supplemental Restraint Systems (SRS). Built using OEM automotive components, this trainer delivers a realistic learning experience while maintaining complete operational safety.
This system is ideally suited for automotive engineering colleges, ITIs, polytechnic institutes, vocational training centers, and service technician programs, enabling both theoretical instruction and hands-on diagnostics practice.
ALTERNATOR TRAINER AZA1247
The AZA1247 AZALAB Alternator Trainer is a hands-on automotive electrical training system designed to demonstrate the working principles, construction, and diagnostics of an automotive alternator with external voltage regulation. Built using OEM automotive components, this trainer provides a realistic and safe learning platform for students, technicians, and trainees to understand vehicle charging systems in depth.
This system is ideal for automotive engineering institutes, ITIs, polytechnics, vocational training centers, and service technician programs, supporting both theoretical instruction and practical experimentation.
ARC WELDING MACHINE AZA1234
The AZA1234 Arc Welding Machine by A Z A Lab is a high-performance industrial welding solution engineered for demanding fabrication, maintenance, and structural welding applications. Designed using advanced inverter technology, this machine delivers superior arc stability, high efficiency, and reliable welding performance across a wide range of electrode types and materials.
With an inverter frequency of up to 20 kHz, the AZA1234 ensures fast dynamic response, reduced spatter, and excellent weld bead appearance. Its robust electrical design supports a high duty cycle, allowing continuous operation under heavy loads while maintaining consistent welding output—even with output cable lengths of up to 100 meters.
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
Related products
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
Standards Compliance
- ASTM D92 (Cleveland Open Cup)
CLASSIC OPEN CUP FLASH POINT APPARATUS AZA1294
The AZA LAB Classic Open Cup Flash Point Apparatus AZA1294 is a reliable and cost-effective laboratory instrument designed for accurate determination of flash point temperature of petroleum products and combustible liquids using the Cleveland Open Cup (COC) method.
Manufactured in full compliance with ASTM D92 and ISO 2592 standards, the AZA1294 is ideally suited for petroleum laboratories, quality control facilities, educational institutions, refinery laboratories, and industrial safety testing environments where dependable flash point determination is essential.
The apparatus combines a classic manual testing approach with durable construction, stable heating performance, and straightforward operation, making it an excellent solution for routine laboratory testing, operator training, and quality assurance applications.
LIQUID PETROLEUM PRODUCTS HYDROCARBON TESTER AZA1316
The AZA1316 Liquid Petroleum Products Hydrocarbon Analyzer from AZA Lab is a specialized laboratory instrument designed for the quantitative determination of aromatic hydrocarbons, olefins, and saturated hydrocarbons in liquid petroleum fractions. This analyzer delivers accurate, reliable, and repeatable results, making it an essential tool for petroleum refining, fuel quality control, regulatory compliance, and research laboratories.
With its ready-to-use vertical design, advanced detection system, and automated cleaning features, the AZA1316 ensures efficient operation with minimal operator intervention while maintaining high analytical precision.
OIL & GAS SAMPLING CYLINDERS – SINGLE END WITH DIP LINE AZA1274
AZA LAB Sampling Cylinders & Gas Sampling Bombs are robust, high‑pressure vessels engineered for safe, reliable collection, storage, and transport of liquids and gases in demanding industrial environments. Available in single‑ended, double‑ended, and flat‑ended variants, they are constructed from premium materials like stainless steel (304/316 L) and Monel, offering corrosion resistance and durable performance . TPED, CE, and ISO certifications ensure compliance with international safety and transport regulations. Each cylinder features precision-engineered NPT connections (¼″ or ½″), customizable volumes from 150 cc to 10 L, and pressure ratings up to 5000 psig, making them ideal for applications in refineries, petrochemical labs, chromatographic analysis, and gas sampling in high‑pressure systems . Hydrostatic testing guarantees reliable integrity under rigorous conditions, while additional options—such as specialized valves, burst discs, dip tubes, and protective carrying cases—allow for tailored configurations to meet specific sampling needs.
PENSKY–MARTENS CLOSED CUP FLASH POINT TESTER AZA1278
The AZA1278 Pensky–Martens Closed Cup Flash Point Tester is a high-precision, microcomputer-controlled instrument designed for accurate determination of flash points of petroleum products under controlled conditions.
Fully compliant with ASTM D93, the system supports Procedures A, B, and C, making it suitable for a wide range of fuels, lubricants, and viscous petroleum samples. It is engineered for reliability, repeatability, and safe laboratory operation.
Standards Compliance
- ASTM D93 (Pensky–Martens Closed Cup)
PETROLEUM PRODUCT DISTILLATION TESTER AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.