SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
Description
Reliable Flash & Fire Point Determination
The flash point represents the lowest temperature at which vapors ignite momentarily when exposed to an ignition source, while the fire point indicates sustained combustion. These parameters are critical for evaluating fire hazards, storage safety, transportation compliance, and product classification.
AZA1289 utilizes a semi-automated ignition and detection system, reducing operator dependency while maintaining flexibility during test setup. The analyzer automatically applies the ignition source at programmed temperature intervals, while a sensitive flame detection system identifies flash and fire points with high accuracy.
Key Features
ASTM D92 & ISO 2592 Compliance
-
Fully conforms to Cleveland Open Cup (COC) test requirements
-
Suitable for regulatory, contractual, and quality assurance testing
Semi-Automated Operation
-
Automated ignition and flash detection
-
Manual sample cup placement for controlled operation
-
Ideal for medium- to high-throughput laboratories
Uniform Heating System
-
Thermostatically controlled aluminum heating block
-
Ensures stable and uniform temperature ramp as per ASTM protocol
Digital Control & Monitoring
-
Digital temperature display with high-accuracy thermocouple
-
Programmable heating rate and ignition timing
-
Automatic test termination upon flash detection
Robust & Safe Design
-
Stainless steel sample cup (75 ml), corrosion resistant and easy to clean
-
Over-temperature protection and ignition shielding
-
Gas cut-off and temperature limiter for enhanced safety
Compact Benchtop Configuration
-
Space-saving design suitable for standard laboratory benches
-
Low maintenance and long service life
Typical Applications
-
Petroleum Refineries
-
Lubricant Manufacturing Plants
-
Fuel Quality Control Laboratories
-
Chemical & Solvent Testing Facilities
-
Fire & Transport Safety Departments
-
Academic & Industrial R&D Laboratories
Technical Specifications
| Feature | Specification |
|---|---|
| Model | AZA1289 |
| Test Method | Cleveland Open Cup (ASTM D92, ISO 2592) |
| Flash Point Range | Ambient to 400°C |
| Fire Point Detection | Yes |
| Sample Cup Capacity | 75 ml |
| Heating Rate | Programmable, ASTM D92 compliant |
| Ignition Source | Electric or gas, automatic |
| Temperature Measurement | Digital display with thermocouple |
| Safety Systems | Over-temperature shutoff, ignition shield |
| Power Supply | 230V AC, 50/60 Hz |
| Dimensions (W × D × H) | 320 × 380 × 400 mm |
| Net Weight | 13 kg |
Why Choose AZA1289
-
Proven ASTM D92 compliant performance
-
Improved accuracy over manual COC testers
-
Reduced operator error with semi-automation
-
Cost-effective alternative to fully automated systems
-
Durable construction for long-term laboratory use
Frequently Asked Questions (FAQ)
Q1: What makes AZA1289 semi-automated?
Heating and ignition are automated, while sample placement and cup handling remain manual, offering flexibility with improved accuracy.
Q2: Is it suitable for high flash point products?
Yes. It is designed for materials with flash points above 79°C, including oils, lubricants, and fuels.
Q3: Does it comply with international standards?
Yes. AZA1289 fully complies with ASTM D92 and ISO 2592.
Q4: How does it differ from a manual COC tester?
Unlike manual units, AZA1289 features automatic ignition, programmable heating, and digital temperature monitoring, improving safety and repeatability.
Q5: Is it suitable for routine QC testing?
Absolutely. It is ideal for daily quality control, compliance testing, and safety evaluation.
Model: AZA1289 – Semi-Automated Cleveland Open Cup Flash Point Analyzer
Additional information
| Test Method |
Cleveland Open-Cup (ASTM D92) |
|---|---|
| Flash Point Range |
Ambient to 400°C |
| Fire Point Detection |
Yes |
| Sample Cup Capacity |
75 ml |
-
Automated operation with an 8.4″ touchscreen, easy one-click start, and audible alerts on completion
-
Rapid heating modes: Standard, rapid, or user-defined rates (1–20 °C/min)
-
Versatile ignition: Switch easily between gas or electric igniter sources
-
Unknown sample detection: Built-in “search” mode to automatically locate flash point in unmarked samples
-
Safety & precision: Automatic barometric pressure correction and comprehensive interlocks ensure reliable operation
-
Power: 230 VAC, 50 Hz, 1.5 kW
-
Heating: 1000 W coil heater (230 V) with precise thermal profiling
-
Cooling: Integrated centrifugal blower (56.5 CFM) for rapid cooldown
-
Measurement: PT100 Class A sensors on sample (0–400 °C) and bath (0–500 °C); ionization ring flash detection; ambient pressure range: 700–1100 hPa
-
Dimensions & Weight: W 410 × D 420 × H 330 mm; approx. 16 kg
-
Environmental: Operational in 10–35 °C at ≤80% RH
You may also like…
ADVANCED TRIAXIAL TEST SYSTEM (UU–CU–CD CAPABLE) AZA1296
The AZA LAB Advanced Triaxial Test System AZA1296 is a fully automated geotechnical laboratory testing system designed for accurate determination of soil shear strength and deformation characteristics under controlled stress and drainage conditions.
The system supports all major triaxial compression testing modes including:
- Unconsolidated Undrained (UU)
- Consolidated Undrained (CU)
- Consolidated Drained (CD)
Engineered for high-precision geotechnical analysis, the AZA1296 replicates in-situ soil stress conditions to evaluate soil stability, strength behavior, pore pressure response, and failure mechanisms under axial loading.
The system integrates servo-controlled loading, automatic pressure regulation, real-time pore pressure monitoring, automated data acquisition, and advanced software analysis, making it ideal for geotechnical laboratories, civil engineering projects, infrastructure development, research institutions, and academic applications.
AIR BAG TRAINER AZA1246
The AZA1246 AZALAB Air Bag Trainer is a comprehensive educational training platform designed to demonstrate the structure, operation, diagnostics, and fault analysis of modern automotive airbag systems, also known as Supplemental Restraint Systems (SRS). Built using OEM automotive components, this trainer delivers a realistic learning experience while maintaining complete operational safety.
This system is ideally suited for automotive engineering colleges, ITIs, polytechnic institutes, vocational training centers, and service technician programs, enabling both theoretical instruction and hands-on diagnostics practice.
ALTERNATOR TRAINER AZA1247
The AZA1247 AZALAB Alternator Trainer is a hands-on automotive electrical training system designed to demonstrate the working principles, construction, and diagnostics of an automotive alternator with external voltage regulation. Built using OEM automotive components, this trainer provides a realistic and safe learning platform for students, technicians, and trainees to understand vehicle charging systems in depth.
This system is ideal for automotive engineering institutes, ITIs, polytechnics, vocational training centers, and service technician programs, supporting both theoretical instruction and practical experimentation.
ARC WELDING MACHINE AZA1234
The AZA1234 Arc Welding Machine by A Z A Lab is a high-performance industrial welding solution engineered for demanding fabrication, maintenance, and structural welding applications. Designed using advanced inverter technology, this machine delivers superior arc stability, high efficiency, and reliable welding performance across a wide range of electrode types and materials.
With an inverter frequency of up to 20 kHz, the AZA1234 ensures fast dynamic response, reduced spatter, and excellent weld bead appearance. Its robust electrical design supports a high duty cycle, allowing continuous operation under heavy loads while maintaining consistent welding output—even with output cable lengths of up to 100 meters.
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
Related products
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
Standards Compliance
- ASTM D92 (Cleveland Open Cup)
FULLY AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1287
The AZA1287 Atmospheric Distillation Analyzer from AZA Lab is a fully automated, high-precision distillation testing system designed for petroleum laboratories that require ASTM D86-compliant determination of boiling range characteristics. Engineered for accuracy, repeatability, and high-throughput operation, the AZA1287 is ideal for testing gasoline, diesel, kerosene, jet fuel, light hydrocarbons, and other petroleum fractions.
Atmospheric distillation testing plays a critical role in evaluating fuel volatility, composition, and performance, directly influencing fuel quality, emissions compliance, and operational safety. The AZA1287 automates the complete distillation process—eliminating manual intervention, reducing operator error, and ensuring consistent, regulation-compliant results.
GASOLINE OXIDATION STABILITY TESTER AZA1318
The AZA1318 Gasoline Oxidation Stability Tester from AZA Lab is a fully automated laboratory instrument designed to determine the oxidation stability of gasoline using the induction period method, in strict accordance with GB/T 8018-2015 and ASTM D525.
Oxidation stability testing is essential for evaluating a gasoline’s resistance to degradation during storage and use. By subjecting fuel samples to accelerated oxidation conditions, the AZA1318 accurately measures the induction period, providing reliable insight into fuel quality, shelf life, and compliance with regulatory specifications.
PENSKY–MARTENS CLOSED CUP FLASH POINT TESTER AZA1278
The AZA1278 Pensky–Martens Closed Cup Flash Point Tester is a high-precision, microcomputer-controlled instrument designed for accurate determination of flash points of petroleum products under controlled conditions.
Fully compliant with ASTM D93, the system supports Procedures A, B, and C, making it suitable for a wide range of fuels, lubricants, and viscous petroleum samples. It is engineered for reliability, repeatability, and safe laboratory operation.
Standards Compliance
- ASTM D93 (Pensky–Martens Closed Cup)
PROGRAMMABLE FULLY-AUTOMATED CLEVELAND OPEN-CUP FLASH & FIRE POINT ANALYZER AZA1290
The AZA Lab Programmable Fully-Automated Cleveland Open-Cup Flash & Fire Point Analyzer AZA1290 is a high-precision petroleum testing instrument designed for fully automated determination of flash and fire points of petroleum products, lubricants, oils, bituminous materials, and combustible liquids in accordance with ASTM D92 and ISO 2592 standards.
Engineered for modern petroleum laboratories, the AZA1290 combines intelligent automation, advanced safety systems, precision temperature control, and comprehensive data management to deliver highly repeatable and operator-independent test results.
The system automates the complete testing cycle including heating control, ignition application, flash detection, fire point detection, result recording, and emergency shutdown, significantly improving laboratory efficiency, testing consistency, and operational safety.
SEDIMENT EXTRACTION TESTER AZA1313
The AZA1313 Sediment Extraction Tester from AZA Lab is a precision laboratory instrument engineered for the accurate determination of sediment content in crude oils and fuel oils using the extraction method specified in ASTM D473. Designed for reliability, consistency, and long-term laboratory use, this tester is an essential tool for petroleum refineries, inspection laboratories, and fuel quality control facilities.
Sediment content is a critical quality parameter that directly impacts storage stability, processing efficiency, pipeline integrity, and combustion performance of petroleum products. The AZA1313 ensures precise sediment measurement by extracting insoluble material using toluene, delivering dependable results across sediment concentrations ranging from 0.01% to 0.40% by mass, with capability for higher concentrations when required.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples
Rock
Aggregate
Cement
Concrete
Soil
Steel
Bitumen/Asphalt
Security Survey Equipment
General Items