SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER(AZA‑1289)
- Semi-automated Cleveland Open Cup flash point tester
- Conforms to ASTM D92 and ISO 2592
- Suitable for petroleum, lubricants, and chemical testing
- Manual sample cup handling with automated ignition
- Built-in digital temperature display
- Compact benchtop design with safety features
- High accuracy thermocouple monitoring
- Cost-effective alternative to full automation
Description
Flash Point Analyzer Semi Automated Cleveland Open Cup is engineered for high-precision flash point testing, adhering strictly to ASTM D92 standards. This semi-automated unit is ideal for laboratories requiring robust, cost-effective flash point determination for oils, fuels, and other volatile liquids. With a perfect balance between automation and manual control, it suits medium- to high-throughput testing environments in both industrial and academic settings.
The flash point of a substance indicates the lowest temperature at which its vapors ignite when exposed to an open flame. This is critical for determining the fire hazard associated with flammable liquids. The Cleveland Open Cup (COC) method, particularly for substances with flash points above 79°C, is globally recognized and mandated in quality control and regulatory settings. According to [astm.org/Standards/D92.htm] (non-clickable), ASTM D92 ensures consistency and accuracy in measuring flash and fire points.
The analyzer features a semi-automated gas ignition system with a pilot flame that automatically traverses the cup at preset temperature intervals. A sensitive flame detection sensor identifies the flash point with minimal operator input. The test ends automatically once ignition is detected, and results are displayed on a digital screen for immediate reading and data recording.
The heating mechanism uses a thermostatically controlled aluminum block to ensure uniform heat distribution across the test cup. This guarantees a stable temperature rise rate as per ASTM protocol. The stainless steel cup is corrosion-resistant and easily removable for cleaning and replacement.
Operators can easily adjust the temperature ramp rate, ignition timing, and test duration via a digital control panel. An inbuilt timer alerts the user to critical stages, while the safety system includes a gas cut-off and temperature limiter to prevent overheating. These features ensure compliance with both laboratory safety guidelines and industry regulations.
The semi-automated configuration is ideal for labs needing flexibility—automated ignition and detection reduce human error, while manual sample handling provides control over test setup. This makes it suitable for use in refineries, lubricant manufacturers, transport safety departments, and fire testing labs.
In terms of connectivity, the system includes USB ports for data transfer and compatibility with most LIMS platforms. Test results can be printed or archived for traceability. The unit is bench-top friendly, with a compact design that fits into any lab workflow.
Technicians and quality managers appreciate its low maintenance needs, straightforward operation, and long service life. The included calibration tool ensures ongoing accuracy, making it an excellent return on investment.
To learn more about the ASTM D92 test method and its importance, visit [astm.org/Standards/D92.htm] (non-clickable).
For more details on ASTM D92 methodology, refer to standard documentation via [www.astm.org/Standards/D92.htm] (non-clickable as requested).
Specifications:
| Feature | Details |
|---|---|
| Test Method | Cleveland Open-Cup (ASTM D92) |
| Flash Point Range | Ambient to 400°C |
| Fire Point Detection | Yes |
| Sample Cup Capacity | 75 ml |
| Heating Rate | Programmable, as per ASTM D92 |
| Ignition Source | Electric or gas, automatic |
| Temperature Measurement | Digital display with thermocouple |
| Safety Systems | Over-temp shutoff, ignition shield |
| Power Supply | 230V AC, 50/60 Hz |
| Dimensions (W x D x H) | 32 x 38 x 40 cm |
| Weight | 13 kg |
Frequently Asked Questions (FAQ):
Q1: What makes this model semi-automated?
A: The heating and ignition process are automated, but cup placement and lid operation are manual, offering operator control with some automation benefits.
Q2: Is this analyzer compliant with international testing standards?
A: Yes, it fully complies with ASTM D92 and ISO 2592 for open-cup flash and fire point determination.
Q3: Can it be upgraded to a fully automated version later?
A: No direct upgrade path is offered, but a fully automated version is available separately for labs needing advanced features.
Q4: What materials can be tested with this analyzer?
A: It is suitable for petroleum products, lubricants, and chemical solutions with flash points above 79°C.
Q5: How is this different from a manual Cleveland Open Cup tester?
A: Unlike manual testers, it includes an automatic ignition system and programmable heating, improving accuracy and safety.
Additional information
| Test Method |
Cleveland Open-Cup (ASTM D92) |
|---|---|
| Flash Point Range |
Ambient to 400°C |
| Fire Point Detection |
Yes |
| Sample Cup Capacity |
75 ml |
-
Automated operation with an 8.4″ touchscreen, easy one-click start, and audible alerts on completion
-
Rapid heating modes: Standard, rapid, or user-defined rates (1–20 °C/min)
-
Versatile ignition: Switch easily between gas or electric igniter sources
-
Unknown sample detection: Built-in “search” mode to automatically locate flash point in unmarked samples
-
Safety & precision: Automatic barometric pressure correction and comprehensive interlocks ensure reliable operation
-
Power: 230 VAC, 50 Hz, 1.5 kW
-
Heating: 1000 W coil heater (230 V) with precise thermal profiling
-
Cooling: Integrated centrifugal blower (56.5 CFM) for rapid cooldown
-
Measurement: PT100 Class A sensors on sample (0–400 °C) and bath (0–500 °C); ionization ring flash detection; ambient pressure range: 700–1100 hPa
-
Dimensions & Weight: W 410 × D 420 × H 330 mm; approx. 16 kg
-
Environmental: Operational in 10–35 °C at ≤80% RH
You may also like…
Advanced Triaxial Test System (UU–CU–CD Capable) (AZA 1296)
- UU–CU–CD test modes for complete soil strength profiling
- Automated control of pressure, load, and drainage
- Compatible with clay, silt, sand, and mixed soils
- Integrated data acquisition and real-time graphing
- Meets ASTM D2850, D4767, BS1377, AASHTO standards
- Ideal for geotechnical, research, and academic use
Air Bag Trainer (Model AZA1246)
Alternator Trainer (Model AZA1247)
Arc Welding Machine (AZA 1234)
AutoDist‑86 Glass Distillation (AZA 1282)
AutoFlash – Automated Abel Flash Point Analyzer( AZA 1277)
AZA Lab's AutoFlash-1277 is a fully automated, microcontroller-based Abel Flash Point Analyzer designed to accurately determine the flash points of combustible liquids. Conforming to IP 170, ISO 13736, and IS 1448 (P:20) standards, it ensures precise and safe analysis of samples in the temperature range of -30°C to 70°C, extendable up to 110°C.
Equipped with a built-in PC and touchscreen display, the AutoFlash-170 delivers intuitive operation, automated calibration, advanced ignition options, and rapid heating procedures for high-efficiency testing. Ideal for laboratories, petrochemical industries, and quality control applications, this standalone unit streamlines the testing process with enhanced accuracy, safety interlocks, and programmable procedures.
Related products
Apparatus for Sulfur Content in LPG (AZA 1300 A)
Scope & Application:
The AZA1300A is applicable for the analysis of:
-
Natural gas, processed gases, and final LPG products
-
Volatile sulfur content ranging from 1 mg/kg to 100 mg/kg in gaseous hydrocarbons
-
Volatile sulfur content ranging from 1 mg/kg to 196 mg/kg in liquefied petroleum gases
This makes it indispensable for research institutions, inspection agencies, and refineries requiring rapid and repeatable sulfur testing in compliance with environmental and safety regulations.
Key Features:
-
Advanced Optical Detection System
Utilizes the most advanced ultraviolet fluorescence (UVF) technology with high-purity optical components to deliver ultra-high sensitivity and consistent performance. -
Imported UV Lamp Assembly
Equipped with a world-class UV lamp, ensuring excellent signal stability, long operational life, and superior accuracy during trace sulfur detection. -
Integrated Nafion Tube Membrane Dryer (U.S. Origin)
Incorporates an imported Nafion membrane dryer for exceptional moisture removal, maintaining low humidity levels and stable signal response even under varying environmental conditions. -
Automatic Calibration & Curve Management
The system enables creation, storage, and recall of working curves, allowing users to perform repeated analyses without re-establishing calibration — saving time and minimizing operator error. -
Multi-Sample Capability
Through optional gas, liquid, and solid samplers, the AZA1300A supports testing of diverse sample types — from gaseous LPG to viscous hydrocarbons or solid matrices — ensuring universal analytical flexibility. -
User-Friendly Software Interface
Features a Windows-based Chinese/English bilingual interface, intuitive operation menus, and real-time data acquisition and display for easy handling and efficient workflow management. -
High-Temperature Combustion & Control
The furnace temperature can be precisely regulated up to 1100°C, ensuring complete oxidation and accurate measurement of total sulfur content. -
High Stability & Low Maintenance
Designed with high-quality materials, reliable electronic circuitry, and advanced filtration systems for long-term stability, minimal maintenance, and reduced operational downtime.
Automated Cleveland Open Cup Flash Point & Fire Point Analyzer(AZA 1276)
- Model: AutoFlash-1276 (v2.0) Fully automated analyzer
- Complies with ASTM D92, ISO 2592, IS 1448 (P:69), IP 36
- Measures flash point and fire point up to 400°C
- Ideal for viscous petroleum products (excluding fuel oils)
- Microcontroller-based system with programmable logic
- Auto ignition, detection, and fire sustain measurement
- Used in QA/QC, R&D labs, refineries, and bitumen testing
AZA-LAB Classic Open Cup Flash Point Apparatus (AZA – 1294)
Fully Automated Atmospheric Distillation Analyzer (AZA 1287)
- Complies with ASTM D86 for atmospheric distillation
- Fully automated operation from start to residue
- Real-time display of temperature and volume curves
- Built-in safety, cooling, and error detection systems
- Touchscreen user interface with method presets
- USB, LAN, and LIMS data connectivity
- Suitable for diesel, gasoline, and jet fuel analysis
- Fast, repeatable, and compliant distillation results
Gum Content Tester -AZA1317
The Gum Content Tester (Model: AZA-1317) from AZA Lab is designed to determine the existent gum content in aviation gasoline and motor gasoline, helping assess fuel cleanliness and stability.
(Note: Not suitable for testing aviation turbine fuel.)
This precision instrument ensures accurate, reliable, and efficient results, making it ideal for use in laboratories, refineries, and fuel quality inspection centres.
Precision Automated Distillation Analyzer (AZA 1281)
Programmable Fully‑Automated Cleveland Open‑Cup Flash & Fire Point Analyzer(AZA 1290)
- Fully automated Cleveland Open-Cup flash & fire point tester
- Complies with ASTM D92 and ISO 2592 standards
- Ideal for petroleum, lubricants, and chemical products
- User-friendly touchscreen interface with data logging
- Built-in safety features with auto shutoff
- Programmable heating and ignition cycles
- USB, RS232, and Ethernet ports for easy connectivity
- Compact and durable benchtop design
Semi‑automated atmospheric distillation analyzer(AZA 1285)
The AutoDist‑86 by Aza Lab is a semi-automated desktop analyzer designed for petroleum-product distillation tests under atmospheric pressure. Compliant with major standards—ASTM D86, D850, D1078, ISO 3405, IP 123, IP 195—it’s capable of accurately distilling hydrocarbon samples ranging from gasoline to diesel and aromatics
Rock
Aggregate
Cement
Concrete
Soil
Steel
Bitumen/Asphalt
Security Survey Equipment
General Items