Apparatus for Hydrogen Sulfide Tester – AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314 from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an H₂S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
Description
Key Features & Applications
-
Accurate Air Flow Control: Digital mass flow meter ensures precise air flow measurement and regulation.
-
Standards Compliance: Fully meets ASTM D7621, IP570, and ISO 8217 standards for reliable results.
-
Automatic Operation: Microcomputer-controlled system enables automatic measurement and calculation.
-
Efficient Cooling: Semiconductor refrigeration gas phase processor provides fast and consistent cooling.
-
High-Quality Components: KAYCAN Fisher-type glass reaction tube and Luer-type sintered filter with special adsorbent ensure precise extraction and filtration.
-
Accurate Detection: KAYCAN H2S200 detection system delivers direct and reliable readings.
-
Safe and Convenient: Quick screw cap design allows easy sealing and safe operation.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1314 |
| Measuring Range | 0–250 mg/kg H₂S |
| Ambient Requirements | 15–30°C, RH ≤ 80% |
| Viscosity Range | Up to 3000 mm²/s |
| Detection Mode | Electrochemical sensor |
| Test Time | 15 minutes |
| Sample Volume | 1 ml, 2 ml, 5 ml (depending on H₂S concentration) |
| Dilute Volume | 20 ml |
| Rated Voltage | AC 220V ±10%, 50 Hz |
| Total Power | 300 W |
| Dimensions (L×W×H) | 420 × 500 × 340 mm |
| Net Weight | 20 kg |
Why Choose AZA1314?
-
Provides fast, accurate, and repeatable H₂S measurements in fuel oils.
-
Fully compliant with international standards, ensuring reliable lab and production results.
-
Automatic and user-friendly, minimizing operator error and improving efficiency.
-
Designed for durability, safety, and precise control in laboratory and refinery environments.
Related products
Advanced Triaxial Test System (UU–CU–CD Capable) (AZA 1296)
- UU–CU–CD test modes for complete soil strength profiling
- Automated control of pressure, load, and drainage
- Compatible with clay, silt, sand, and mixed soils
- Integrated data acquisition and real-time graphing
- Meets ASTM D2850, D4767, BS1377, AASHTO standards
- Ideal for geotechnical, research, and academic use
Cleveland Open-Cup Flash Point Tester AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
Dist‑86S Semi‑Automated Distillation Analyzer AZA1283
The AZA1283 Dist-86S Semi-Automated Distillation Analyzer from AZA Lab is a robust, reliable, and precision-engineered instrument designed for determining the distillation characteristics of petroleum products and volatile organic liquids in accordance with ASTM D86 and equivalent international standards.
Combining operator control with intelligent automation, the AZA1283 is ideally suited for refineries, petrochemical laboratories, quality control facilities, research institutions, and regulatory testing laboratories that require accurate, repeatable, and standards-compliant distillation analysis without the complexity of fully automated systems.
Flash Point D93 Abel Closed Cup Tester AZA1278
The AZA1278 Flash Point D93 Abel Closed Cup Tester from AZA Lab is a high-precision laboratory instrument designed for accurate determination of the closed cup flash point of petroleum products. It complies fully with ASTM D93 (Pensky-Martens Closed Cup) test methods, ensuring reliable, repeatable, and safety-critical measurements.
This instrument is widely used in petroleum laboratories, refineries, fuel testing centers, and quality control facilities to evaluate the flammability characteristics of fuels, lubricants, oils, and other petroleum fractions
Petroleum Product Distillation Tester AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
XRF Sulfur Content Tester AZA1300
The AZA Lab Sulfur Content Analyzer – AZA1300 is a state-of-the-art instrument designed for precise and rapid determination of sulfur content in petroleum, petrochemical, and coal chemical products. Based on the energy-dispersive X-ray fluorescence (EDXRF) principle, it integrates advanced electrical, mechanical, and microprocessor technologies to deliver high accuracy, reliability, and ease of operation.
Engineered to comply with ASTM D4294, GB/T 17040, SH/T0742, and GB/T11140 standards, the Model 1300 provides dependable measurement results with excellent repeatability and reproducibility. Its intelligent design ensures automatic corrections for environmental conditions such as temperature, pressure, and C/H ratio, making it a versatile solution for laboratories and production facilities alike.
Compact, user-friendly, and equipped with advanced safety features, the AZA1300 is an ideal tool for routine quality control, process monitoring, and research applications where sulfur determination is critical.