Oil & Gas Sampling Cylinders Single End with Dip Line (AZA- 1274)
AZA LAB Sampling Cylinders & Gas Sampling Bombs are robust, high‑pressure vessels engineered for safe, reliable collection, storage, and transport of liquids and gases in demanding industrial environments. Available in single‑ended, double‑ended, and flat‑ended variants, they are constructed from premium materials like stainless steel (304/316 L) and Monel, offering corrosion resistance and durable performance . TPED, CE, and ISO certifications ensure compliance with international safety and transport regulations. Each cylinder features precision-engineered NPT connections (¼″ or ½″), customizable volumes from 150 cc to 10 L, and pressure ratings up to 5000 psig, making them ideal for applications in refineries, petrochemical labs, chromatographic analysis, and gas sampling in high‑pressure systems . Hydrostatic testing guarantees reliable integrity under rigorous conditions, while additional options—such as specialized valves, burst discs, dip tubes, and protective carrying cases—allow for tailored configurations to meet specific sampling needs.
Description
| Product Code | Capacity (ml) | Connection | Size (Ø × L mm) |
| AZA- 110 | 500 | ¼″ NPT | Ø 60 × 320 |
| AZA- 111 | 1000 | ¼″ NPT | Ø 88.9 × 300 |
| AZA- 112 | 2000 | ½″ NPT | Ø 102 × 350 |
| AZA- 113 | 5000 | ½″ NPT | Ø 150 × 350 |
| AZA- 114 | 10000 | ½″ NPT | Ø 230 × 350 |
Core Features
- Valve Configurations: Single‑ended, double‑ended (most common), flat‑ended cylinders for varied sampling profiles.
- Materials: Stainless Steel (SS 304, SS 316 with dip tube), Monel options
- Pressure Ratings: Standard 500–6000 psi; high‑pressure variants up to 10,000 psi
- Certifications: CE, ISO 9001, TPED/DOT, PED compliant
- Connection Types: ¼″, ½″ NPT (M/F), BSP variants
- Sizes & Capacities: Range from 75 cc to 10,000 cc; e.g., Ø60×320 mm (500 cc), Ø230×350 mm (10 L)
- Finishes & Safety: Internal sandblast/electropolish; hydrostatic pressure tested; with built-in relief valves and safety burst discs
- Customization Options: Internal coatings (e.g. sulfonation for sulfur-sensitive samples), valves, quick-connects, carrying handles, and transport/storage cases
-
Sampling hydrocarbons in refineries and petrochemical plants
-
Laboratory collection, chromatographic analysis (GC), and condensate/fossil fuel testing.
-
Transport/storage under pressure (oil, gas, vacuum systems)
-
Snubbers, surge accumulators, reaction vessels, transformer oil testing, molecular sieves, and experimental chambers
| Capacity | Material | Connection | Dimensions (Ø×L) |
|---|---|---|---|
| 150 cc | SS/Monel | ¼″ NPT | Ø 60 × 320 mm |
| 300 cc | SS/Monel | ¼″ NPT | Ø 60 × 320 mm |
| 500 cc | SS/Monel | ¼″ NPT | Ø 60 × 320 mm |
| 1000 cc | SS/Monel | ½″ NPT | Ø 102 × 350 mm |
| 5000 cc | SS/Monel | ½″ NPT | Ø 150 × 350 mm |
| 10,000 cc | SS/Monel | ½″ NPT | Ø 230 × 350 mm |
Related products
Advanced Triaxial Test System (UU–CU–CD Capable) (AZA 1296)
- UU–CU–CD test modes for complete soil strength profiling
- Automated control of pressure, load, and drainage
- Compatible with clay, silt, sand, and mixed soils
- Integrated data acquisition and real-time graphing
- Meets ASTM D2850, D4767, BS1377, AASHTO standards
- Ideal for geotechnical, research, and academic use
Apparatus for Hydrogen Sulfide Tester – AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314 from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an H₂S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
Apparatus for Sulfur Content in LPG AZA1300A
Apparatus for Sulfur Content in LPG – AZA1300A
The AZA1300A Apparatus for Sulfur Content in LPG from Azalab is a high-performance analytical system designed for the accurate determination of total volatile sulfur in gaseous hydrocarbons and liquefied petroleum gases (LPG). Developed in strict accordance with ASTM D6667, this advanced instrument utilizes the Ultraviolet Fluorescence (UVF) detection method, delivering exceptional sensitivity, stability, and repeatability across a wide concentration range.
The AZA1300A is purpose-built for refineries, petrochemical plants, natural gas processing units, inspection laboratories, and quality assurance facilities, where precise sulfur measurement is critical for product quality, regulatory compliance, and environmental safety
Automated Cleveland Open Cup Flash Point & Fire Point Analyzer AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
The Automated Cleveland Open Cup Flash Point Analyzer (Model: AZA1279) from AZA Lab is a fully automated, microprocessor-controlled flash point testing system designed for accurate determination of the flash point of petroleum products using the Cleveland Open Cup (COC) method. Engineered in strict compliance with ASTM D92, the AZA1279 delivers reliable, repeatable, and traceable results for laboratories where safety, regulatory compliance, and precision are essential.
Flash point determination plays a vital role in assessing the flammability, handling safety, storage conditions, and transportation classification of combustible liquids. The AZA1279 automates the entire test cycle—heating, ignition, detection, and result recording—minimizing human error while maximizing consistency and operator safety
Fully Automated Atmospheric Distillation Analyzer AZA1287
The AZA1287 Atmospheric Distillation Analyzer from AZA Lab is a fully automated, high-precision distillation testing system designed for petroleum laboratories that require ASTM D86-compliant determination of boiling range characteristics. Engineered for accuracy, repeatability, and high-throughput operation, the AZA1287 is ideal for testing gasoline, diesel, kerosene, jet fuel, light hydrocarbons, and other petroleum fractions.
Atmospheric distillation testing plays a critical role in evaluating fuel volatility, composition, and performance, directly influencing fuel quality, emissions compliance, and operational safety. The AZA1287 automates the complete distillation process—eliminating manual intervention, reducing operator error, and ensuring consistent, regulation-compliant results.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
XRF Sulfur Content Tester AZA1300
The AZA Lab Sulfur Content Analyzer – AZA1300 is a state-of-the-art instrument designed for precise and rapid determination of sulfur content in petroleum, petrochemical, and coal chemical products. Based on the energy-dispersive X-ray fluorescence (EDXRF) principle, it integrates advanced electrical, mechanical, and microprocessor technologies to deliver high accuracy, reliability, and ease of operation.
Engineered to comply with ASTM D4294, GB/T 17040, SH/T0742, and GB/T11140 standards, the Model 1300 provides dependable measurement results with excellent repeatability and reproducibility. Its intelligent design ensures automatic corrections for environmental conditions such as temperature, pressure, and C/H ratio, making it a versatile solution for laboratories and production facilities alike.
Compact, user-friendly, and equipped with advanced safety features, the AZA1300 is an ideal tool for routine quality control, process monitoring, and research applications where sulfur determination is critical.