AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
The AZA1279 Automated Cleveland Open Cup Flash Point Analyzer is a fully automated, microprocessor-controlled system designed for precise determination of flash points of petroleum products using the Cleveland Open Cup (COC) method.
Engineered in full compliance with ASTM D92, the instrument delivers accurate, repeatable, and traceable results, making it ideal for laboratories where safety, regulatory compliance, and high-throughput testing are critical.
Standards Compliance
- ASTM D92 (Cleveland Open Cup)
Description
Measurement Capability
- Flash Point Range: Ambient to 400°C
- Suitable for high flash point petroleum products
- Automatic flash detection with high sensitivity
Applications
- Petroleum refineries and fuel terminals
- Lubricant and base oil manufacturers
- Biofuel and alternative fuel testing laboratories
- QA/QC laboratories
- Regulatory and inspection agencies
- Research & development laboratories
System Features
Automation & Control
- Fully automated ASTM D92 test sequence
- Microprocessor-based closed-loop temperature control
- Automatic ignition at defined temperature intervals
- Real-time monitoring and result logging
- Pre-run auto calibration (no external device required)
Functional & Advanced Control Specifications
| Function | Specification |
|---|---|
| Heating System | Cartridge heater, 300 W |
| Heating Rate | Adjustable, 5 to 17 °C/min |
| Cooling Options | Peltier: +10°C to +110°C (air-cooled to +25°C); Optional refrigerated circulator: –30°C to +110°C |
| Stirring System | Stepper motor controlled, 5–100 RPM |
| Ignition System | DC motor-driven; selectable electric / gas igniter |
| Ignition Control | 0.5 to 5°C dipping intervals; precise gas flow control; auto gas ignition; 3-step electric igniter intensity |
| Arm Mechanism | DC motorized swing arm with integrated sensors and igniter |
| Flash Detection | Thermal sensor |
| Fire Detection | UV sensor |
| Auto Calibration | Automatic before each run |
Measurement & Sensor Specifications
| Parameter | Specification |
|---|---|
| Sample Temperature Sensor | PT100 Class A, SS / Glass (–100°C to +150°C) |
| Bath Temperature Sensor | PT100 Class A, disk type (–100°C to +200°C) |
| Ambient Pressure | Built-in sensor |
| Pressure Range | 700–1100 hPa |
Safety & Protection System
| Condition | System Response |
|---|---|
| Over-temperature | Alarm + automatic shutdown |
| Sensor failure (sample/bath) | Test abort with error indication |
| Ignition failure | System alert; ignition disabled |
| Arm malfunction | Test halted |
| Fire detection | Immediate shutdown with alarm |
| Abnormal operation | Fail-safe shutdown |
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1279 |
| Test Method | Cleveland Open Cup (COC) |
| Standard | ASTM D92 |
| Flash Point Range | Ambient to 400°C |
| Heating Rate | 5 to 17 °C/min (adjustable) |
| Sample Volume | 70 ml |
| Display | 7” color touchscreen |
| Data Output | USB export |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Dimensions | 400 × 300 × 350 mm |
| Weight | Approx. 10 kg |
What’s Included
- 1 × AZA1279 Analyzer Unit
- 1 × Cleveland Open Cup Test Assembly
- 1 × Ignition System (Electric / Gas)
- 1 × Calibration Certificate
- 1 × User Manual
Optional Accessories:
- Refrigerated circulator (–30°C capability)
- External printer / LIMS integration
- Spare sensors and ignition components
Operational Advantages
- High repeatability with automated control
- Reduced operator dependency and error
- Flexible ignition and cooling configurations
- Suitable for continuous and high-volume testing
- Compliance with globally accepted ASTM method
Why Choose AZA1279?
- Advanced automation with precise thermal control
- Reliable flash point detection across wide temperature range
- Integrated safety and diagnostic systems
- User-friendly interface with digital data handling
- Robust, long-life laboratory instrument
Additional information
| Model |
AZA 1279 |
|---|---|
| Standard Method |
ASTM D92 (Cleveland Open Cup) |
| Flash Point Range |
Ambient to 400°C |
| Heating Rate |
Adjustable (5 to 17°C/min) |
You may also like…
ADVANCED TRIAXIAL TEST SYSTEM (UU–CU–CD CAPABLE) AZA1296
The AZA LAB Advanced Triaxial Test System AZA1296 is a fully automated geotechnical laboratory testing system designed for accurate determination of soil shear strength and deformation characteristics under controlled stress and drainage conditions.
The system supports all major triaxial compression testing modes including:
- Unconsolidated Undrained (UU)
- Consolidated Undrained (CU)
- Consolidated Drained (CD)
Engineered for high-precision geotechnical analysis, the AZA1296 replicates in-situ soil stress conditions to evaluate soil stability, strength behavior, pore pressure response, and failure mechanisms under axial loading.
The system integrates servo-controlled loading, automatic pressure regulation, real-time pore pressure monitoring, automated data acquisition, and advanced software analysis, making it ideal for geotechnical laboratories, civil engineering projects, infrastructure development, research institutions, and academic applications.
AIR BAG TRAINER AZA1246
The AZA1246 AZALAB Air Bag Trainer is a comprehensive educational training platform designed to demonstrate the structure, operation, diagnostics, and fault analysis of modern automotive airbag systems, also known as Supplemental Restraint Systems (SRS). Built using OEM automotive components, this trainer delivers a realistic learning experience while maintaining complete operational safety.
This system is ideally suited for automotive engineering colleges, ITIs, polytechnic institutes, vocational training centers, and service technician programs, enabling both theoretical instruction and hands-on diagnostics practice.
ALTERNATOR TRAINER AZA1247
The AZA1247 AZALAB Alternator Trainer is a hands-on automotive electrical training system designed to demonstrate the working principles, construction, and diagnostics of an automotive alternator with external voltage regulation. Built using OEM automotive components, this trainer provides a realistic and safe learning platform for students, technicians, and trainees to understand vehicle charging systems in depth.
This system is ideal for automotive engineering institutes, ITIs, polytechnics, vocational training centers, and service technician programs, supporting both theoretical instruction and practical experimentation.
ARC WELDING MACHINE AZA1234
The AZA1234 Arc Welding Machine by A Z A Lab is a high-performance industrial welding solution engineered for demanding fabrication, maintenance, and structural welding applications. Designed using advanced inverter technology, this machine delivers superior arc stability, high efficiency, and reliable welding performance across a wide range of electrode types and materials.
With an inverter frequency of up to 20 kHz, the AZA1234 ensures fast dynamic response, reduced spatter, and excellent weld bead appearance. Its robust electrical design supports a high duty cycle, allowing continuous operation under heavy loads while maintaining consistent welding output—even with output cable lengths of up to 100 meters.
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
Related products
APPARATUS FOR HYDROGEN SULFIDE TESTER AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314 from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an H₂S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
APPARATUS FOR SULFUR CONTENT IN LPG AZA1300A
Apparatus for Sulfur Content in LPG – AZA1300A
The AZA1300A Apparatus for Sulfur Content in LPG from Azalab is a high-performance analytical system designed for the accurate determination of total volatile sulfur in gaseous hydrocarbons and liquefied petroleum gases (LPG). Developed in strict accordance with ASTM D6667, this advanced instrument utilizes the Ultraviolet Fluorescence (UVF) detection method, delivering exceptional sensitivity, stability, and repeatability across a wide concentration range.
The AZA1300A is purpose-built for refineries, petrochemical plants, natural gas processing units, inspection laboratories, and quality assurance facilities, where precise sulfur measurement is critical for product quality, regulatory compliance, and environmental safety
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
DIST-86S SEMI-AUTOMATED DISTILLATION ANALYZER AZA1283
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
DIST-86S SEMI-AUTOMATED DISTILLATION TESTER AZA1288
The AZA Lab Dist-86S Semi-Automated Distillation Tester AZA1288 is a precision-engineered petroleum testing instrument designed for accurate determination of the distillation characteristics of petroleum products and volatile organic liquids in full accordance with ASTM D86 standards.
Built for laboratories requiring dependable performance, repeatability, and operational safety, the AZA1288 combines intelligent semi-automation with operator flexibility. The system is ideally suited for petroleum refineries, fuel inspection laboratories, aviation fuel testing facilities, research institutions, petrochemical plants, and educational laboratories.
The instrument utilizes PID-controlled heating technology, precision temperature monitoring, and an integrated condenser cooling system to ensure highly stable distillation conditions and accurate boiling point determination across a wide range of petroleum fractions.
PETROLEUM PRODUCT DISTILLATION TESTER AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
TAN & TBN (KARL FISCHER MOISTURE TITRATOR) TESTER AZA1315
The AZA1315 Karl Fischer Moisture Titrator from AZA Lab is a high-precision analytical instrument designed for the determination of trace water content in liquid petroleum products, lubricating oils, additives, and related materials using the Coulometric Karl Fischer method.
The instrument is designed and manufactured in full compliance with international and industry standards including GB/T 7600, SH/T 0246, ASTM D1533, and ASTM D6304, ensuring accurate, repeatable, and globally accepted moisture analysis results.
Powered by advanced microcomputer control technology, the AZA1315 delivers fast testing, high sensitivity, and stable performance. Its touch-screen LCD interface, fully automated titration, and built-in thermal printer make it an ideal solution for laboratories and industrial quality control environments requiring precise moisture determination.
X-RAY SULFUR METER TESTER AZA1300B
The X-Ray Sulfur Meter (Model: AZA1300B) from AZA Lab is a highly efficient and precise instrument designed to measure sulfur content in petroleum and petrochemical products during production. It enables fast, non-destructive analysis, making it an essential tool for quality control, process optimization, and regulatory compliance.
Ideal for use in refineries, laboratories, and production sites, this instrument provides accurate, reliable results with minimal sample preparation, ensuring consistent performance and repeatability.