AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279

The AZA1279 Automated Cleveland Open Cup Flash Point Analyzer is a fully automated, microprocessor-controlled system designed for precise determination of flash points of petroleum products using the Cleveland Open Cup (COC) method.

Engineered in full compliance with ASTM D92, the instrument delivers accurate, repeatable, and traceable results, making it ideal for laboratories where safety, regulatory compliance, and high-throughput testing are critical.

Standards Compliance

  • ASTM D92 (Cleveland Open Cup)
Description

Description

Measurement Capability

  • Flash Point Range: Ambient to 400°C
  • Suitable for high flash point petroleum products
  • Automatic flash detection with high sensitivity

Applications

  • Petroleum refineries and fuel terminals
  • Lubricant and base oil manufacturers
  • Biofuel and alternative fuel testing laboratories
  • QA/QC laboratories
  • Regulatory and inspection agencies
  • Research & development laboratories

System Features

Automation & Control

  • Fully automated ASTM D92 test sequence
  • Microprocessor-based closed-loop temperature control
  • Automatic ignition at defined temperature intervals
  • Real-time monitoring and result logging
  • Pre-run auto calibration (no external device required)

Functional & Advanced Control Specifications

Function Specification
Heating System Cartridge heater, 300 W
Heating Rate Adjustable, 5 to 17 °C/min
Cooling Options Peltier: +10°C to +110°C (air-cooled to +25°C); Optional refrigerated circulator: –30°C to +110°C
Stirring System Stepper motor controlled, 5–100 RPM
Ignition System DC motor-driven; selectable electric / gas igniter
Ignition Control 0.5 to 5°C dipping intervals; precise gas flow control; auto gas ignition; 3-step electric igniter intensity
Arm Mechanism DC motorized swing arm with integrated sensors and igniter
Flash Detection Thermal sensor
Fire Detection UV sensor
Auto Calibration Automatic before each run

Measurement & Sensor Specifications

Parameter Specification
Sample Temperature Sensor PT100 Class A, SS / Glass (–100°C to +150°C)
Bath Temperature Sensor PT100 Class A, disk type (–100°C to +200°C)
Ambient Pressure Built-in sensor
Pressure Range 700–1100 hPa

Safety & Protection System

Condition System Response
Over-temperature Alarm + automatic shutdown
Sensor failure (sample/bath) Test abort with error indication
Ignition failure System alert; ignition disabled
Arm malfunction Test halted
Fire detection Immediate shutdown with alarm
Abnormal operation Fail-safe shutdown

Technical Specifications

Parameter Specification
Model AZA1279
Test Method Cleveland Open Cup (COC)
Standard ASTM D92
Flash Point Range Ambient to 400°C
Heating Rate 5 to 17 °C/min (adjustable)
Sample Volume 70 ml
Display 7” color touchscreen
Data Output USB export
Power Supply 220 V ±10%, 50/60 Hz
Dimensions 400 × 300 × 350 mm
Weight Approx. 10 kg

What’s Included

  • 1 × AZA1279 Analyzer Unit
  • 1 × Cleveland Open Cup Test Assembly
  • 1 × Ignition System (Electric / Gas)
  • 1 × Calibration Certificate
  • 1 × User Manual

Optional Accessories:

  • Refrigerated circulator (–30°C capability)
  • External printer / LIMS integration
  • Spare sensors and ignition components

Operational Advantages

  • High repeatability with automated control
  • Reduced operator dependency and error
  • Flexible ignition and cooling configurations
  • Suitable for continuous and high-volume testing
  • Compliance with globally accepted ASTM method

Why Choose AZA1279?

  • Advanced automation with precise thermal control
  • Reliable flash point detection across wide temperature range
  • Integrated safety and diagnostic systems
  • User-friendly interface with digital data handling
  • Robust, long-life laboratory instrument
Additional information

Additional information

Model

AZA 1279

Standard Method

ASTM D92 (Cleveland Open Cup)

Flash Point Range

Ambient to 400°C

Heating Rate

Adjustable (5 to 17°C/min)