CLEVELAND OPEN-CUP FLASH & FIRE POINT TESTER AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
Description
Reliable Cleveland Open Cup Testing
Flash point and fire point testing play a critical role in evaluating the flammability, storage safety, transportation classification, and regulatory compliance of petroleum-based materials. The AZA1292 employs the Cleveland Open Cup (COC) method, which is internationally recognized for high-temperature flash and fire point determination.
Its precise heating control and stable temperature regulation ensure that each test follows the specified heating rates outlined in ASTM D92 and GB/T 3536-2008, minimizing operator influence and improving reproducibility.
Advanced Microcomputer Control & Clear LCD Interface
The AZA1292 is equipped with an advanced single-chip microcomputer control system paired with a clear LCD display featuring an English interface. The menu-driven operation allows users to:
-
Set test parameters easily
-
Monitor real-time sample temperature
-
View test progress clearly
-
Record and store flash point results automatically
With a dedicated record key, test data can be saved instantly, simplifying documentation and laboratory workflow.
Explosion-Proof Electric Heating & Enhanced Safety
Safety is a primary consideration in flash point testing. The AZA1292 utilizes electric furnace heating with no naked flame, providing an explosion-proof and highly stable heating environment. The heating power is continuously adjustable from 0 to 600 W, allowing precise control up to a maximum temperature of 400°C.
Additional safety features include:
-
Integrated wind shield to protect the flame area
-
Flame extinguishing cover for safe and compliant operation
-
Stable RTD PT100 temperature sensing for accurate detection
These features ensure safe operation even in high-temperature testing environments.
Compact, Durable & Cost-Effective Design
The AZA1292 features a stainless-steel workbench with a compact footprint, making it well suited for laboratories with limited space. Its robust construction ensures long-term durability, while the simplified mechanical design results in low maintenance requirements and high cost efficiency.
The instrument supports operation using coal gas or other civil gas sources, providing flexibility in laboratory installations.
Typical Applications
-
Petroleum and lubricant testing laboratories
-
Oil refineries and petrochemical plants
-
Transformer oil and insulating fluid testing
-
Quality control and inspection agencies
-
Academic and research laboratories
-
Regulatory and safety compliance testing
Key Features
-
Cleveland Open Cup flash & fire point tester
-
Complies with ASTM D92 and GB/T 3536-2008
-
Flash point range: 79°C to 400°C
-
Explosion-proof electric furnace heating (no naked flame)
-
Advanced microcomputer temperature control
-
LCD display with English menu interface
-
Automatic test operation with result recording
-
Stainless-steel workbench construction
-
Compact size with high reproducibility and efficiency
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1292 |
| Test Method | Cleveland Open Cup (ASTM D92, GB/T 3536-2008) |
| Flash Point Range | 79°C to 400°C |
| Power Supply | AC 220V ±10%, 50 Hz |
| Maximum Power Consumption | 650 W |
| Heating Method | Electric furnace heating, explosion-proof |
| Heating Power | 0–600 W, continuously adjustable |
| Maximum Temperature | 400°C |
| Temperature Control | Single-chip microcomputer |
| Temperature Display | LCD (English interface) |
| Display Range | 0–400°C |
| Temperature Sensor | RTD, PT100 |
| Ambient Temperature | –10°C to 50°C |
| Relative Humidity | ≤85% |
| Dimensions (L×W×H) | 340 × 320 × 450 mm |
| Flash Detection Device | Included |
Frequently Asked Questions (FAQ)
Q1: Which standards does the AZA1292 comply with?
It fully complies with ASTM D92 and GB/T 3536-2008 for Cleveland Open Cup flash and fire point testing.
Q2: What products can be tested using this instrument?
It is suitable for petroleum products with flash points between 79°C and 400°C, excluding fuel oils.
Q3: Is the heating system safe?
Yes. It uses an explosion-proof electric furnace with no naked flame, along with a flame extinguishing cover.
Q4: Is the instrument easy to operate?
Yes. The LCD English interface, menu-guided operation, and automatic result recording make it very user-friendly.
Q5: Is it suitable for continuous laboratory use?
Absolutely. Its durable stainless-steel construction and stable control system make it ideal for routine QC testing.
Model: AZA1292 – Cleveland Open Cup Flash & Fire Point Tester
Additional information
| Model |
AutoFlash-92 |
|---|---|
| Method |
Cleveland Open Cup (ASTM D92) |
| Operation |
Fully Automated |
| Flash Point Range |
Ambient to 400°C |
- Certified Reference Material (Low Flash Point) – 250 ml
- Certified Reference Material (High Flash Point) – 250 ml
Technical Specifications
User Interface
- Windows-based software
- Stores methods and test results
- Optional printer support
| Feature | Specification |
|---|---|
| Heating | 1000 W Coil Heater @ 230 VAC |
| Heat Rate | 1 – 20°C/min (user programmable) |
| Cooling | Centrifugal Blower, 56.5 CFM, 35 W @ 230 VAC |
| Ignition | Stepper motor controlled; 7-step adjustable brightness (Electric) |
| Arm Movement | Automatic swing arm (Stepper motor controlled) |
| Integrated Components | Sample temperature sensor, Flash Detector, Fire Detector, Igniter |
| Flame Extinguisher | Auto shutter closes over cup on fire/flash detection |
You may also like…
ADVANCED TRIAXIAL TEST SYSTEM (UU–CU–CD CAPABLE) AZA1296
The AZA LAB Advanced Triaxial Test System AZA1296 is a fully automated geotechnical laboratory testing system designed for accurate determination of soil shear strength and deformation characteristics under controlled stress and drainage conditions.
The system supports all major triaxial compression testing modes including:
- Unconsolidated Undrained (UU)
- Consolidated Undrained (CU)
- Consolidated Drained (CD)
Engineered for high-precision geotechnical analysis, the AZA1296 replicates in-situ soil stress conditions to evaluate soil stability, strength behavior, pore pressure response, and failure mechanisms under axial loading.
The system integrates servo-controlled loading, automatic pressure regulation, real-time pore pressure monitoring, automated data acquisition, and advanced software analysis, making it ideal for geotechnical laboratories, civil engineering projects, infrastructure development, research institutions, and academic applications.
AIR BAG TRAINER AZA1246
The AZA1246 AZALAB Air Bag Trainer is a comprehensive educational training platform designed to demonstrate the structure, operation, diagnostics, and fault analysis of modern automotive airbag systems, also known as Supplemental Restraint Systems (SRS). Built using OEM automotive components, this trainer delivers a realistic learning experience while maintaining complete operational safety.
This system is ideally suited for automotive engineering colleges, ITIs, polytechnic institutes, vocational training centers, and service technician programs, enabling both theoretical instruction and hands-on diagnostics practice.
ALTERNATOR TRAINER AZA1247
The AZA1247 AZALAB Alternator Trainer is a hands-on automotive electrical training system designed to demonstrate the working principles, construction, and diagnostics of an automotive alternator with external voltage regulation. Built using OEM automotive components, this trainer provides a realistic and safe learning platform for students, technicians, and trainees to understand vehicle charging systems in depth.
This system is ideal for automotive engineering institutes, ITIs, polytechnics, vocational training centers, and service technician programs, supporting both theoretical instruction and practical experimentation.
ARC WELDING MACHINE AZA1234
The AZA1234 Arc Welding Machine by A Z A Lab is a high-performance industrial welding solution engineered for demanding fabrication, maintenance, and structural welding applications. Designed using advanced inverter technology, this machine delivers superior arc stability, high efficiency, and reliable welding performance across a wide range of electrode types and materials.
With an inverter frequency of up to 20 kHz, the AZA1234 ensures fast dynamic response, reduced spatter, and excellent weld bead appearance. Its robust electrical design supports a high duty cycle, allowing continuous operation under heavy loads while maintaining consistent welding output—even with output cable lengths of up to 100 meters.
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
Related products
APPARATUS FOR HYDROGEN SULFIDE TESTER AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314Â from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an Hâ‚‚S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
DIST-86S SEMI-AUTOMATED DISTILLATION ANALYZER AZA1283
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
GUM CONTENT TESTER AZA1317
The AZA1317 Gum Content Tester from AZA Lab is a precision laboratory instrument designed to determine the existent gum content in aviation gasoline and motor gasoline. Existent gum testing is critical for evaluating fuel cleanliness, storage stability, and combustion performance, helping prevent injector fouling, valve deposits, and engine performance degradation.
Note: This instrument is not suitable for aviation turbine fuel testing.
With accurate temperature control, efficient evaporation, and multi-sample capability, the AZA1317 is ideal for fuel testing laboratories, refineries, inspection agencies, and quality control departments.
PENSKY–MARTENS CLOSED CUP FLASH POINT TESTER AZA1278
The AZA1278 Pensky–Martens Closed Cup Flash Point Tester is a high-precision, microcomputer-controlled instrument designed for accurate determination of flash points of petroleum products under controlled conditions.
Fully compliant with ASTM D93, the system supports Procedures A, B, and C, making it suitable for a wide range of fuels, lubricants, and viscous petroleum samples. It is engineered for reliability, repeatability, and safe laboratory operation.
Standards Compliance
- ASTM D93 (Pensky–Martens Closed Cup)
PETROLEUM PRODUCT DISTILLATION TESTER AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.
XRF SULFUR CONTENT TESTER AZA1300
The AZA Lab Sulfur Content Analyzer – AZA1300 is a state-of-the-art instrument designed for precise and rapid determination of sulfur content in petroleum, petrochemical, and coal chemical products. Based on the energy-dispersive X-ray fluorescence (EDXRF) principle, it integrates advanced electrical, mechanical, and microprocessor technologies to deliver high accuracy, reliability, and ease of operation.
Engineered to comply with ASTM D4294, GB/T 17040, SH/T0742, and GB/T11140 standards, the Model 1300 provides dependable measurement results with excellent repeatability and reproducibility. Its intelligent design ensures automatic corrections for environmental conditions such as temperature, pressure, and C/H ratio, making it a versatile solution for laboratories and production facilities alike.
Compact, user-friendly, and equipped with advanced safety features, the AZA1300 is an ideal tool for routine quality control, process monitoring, and research applications where sulfur determination is critical.
Rock
Aggregate
Cement
Concrete
Soil
Steel
Bitumen/Asphalt