ASH DETERMINATION INSTRUMENT AZA1319
The AZA1319 Ash Determination Instrument from AZA Lab is a precision laboratory system designed for the accurate determination of ash content in petroleum products, in full compliance with GB/T 508 and ASTM D482 – Standard Test Method for Ash Content of Petroleum Products.
Engineered for reliability, temperature stability, and long service life, the AZA1319 is ideal for refineries, petrochemical laboratories, fuel testing facilities, and quality control departments where consistent ash measurement is essential for product evaluation and regulatory compliance.
Note: This instrument is not suitable for petroleum products containing ash-forming additives, lubricating oils with lead, or used engine crankcase oils, in accordance with the referenced test standards.
Description
Applications
-
Ash content determination in petroleum products
-
Refinery and petrochemical quality control
-
Fuel and oil testing laboratories
-
Research and analytical institutions
-
Compliance testing as per GB/T 508 and ASTM D482
Technical Specifications
| Component | Specification |
|---|---|
| Model | AZA1319 |
| Applicable Standards | GB/T 508, ASTM D482 |
| Box-Type Heating Furnace | |
| Power Supply | AC 220V ±10%, 50 Hz |
| Operating Temperature | 775 ±25 °C |
| Temperature Rise Time (Empty Furnace) | ≤ 50 minutes |
| Temperature Uniformity | ≤ 15 °C |
| Temperature Control Stand | |
| Power Supply | AC 220V ±10%, 50 Hz |
| Maximum Control Temperature | 1200 °C |
| Controller Type | Digital LED display |
| Electric Heating Plate | |
| Plate Diameter | Φ85 mm |
| Power Supply | AC 220V ±10%, 50 Hz |
| Rated Temperature | 400 °C |
| Heating Power Control | 1–6 grades, continuously adjustable |
Why Choose AZA1319?
-
Standards Compliant: Fully conforms to GB/T 508 and ASTM D482
-
Accurate & Reliable: Stable temperature control ensures repeatable ash determination
-
Compact & Durable: Fire-resistant construction with long service life
-
Efficient Operation: Fast heating and adjustable controls improve productivity
-
Laboratory-Ready: Ideal for routine QC and analytical testing environments
Frequently Asked Questions (FAQ)
Q1: What does the AZA1319 measure?
It determines the ash content in petroleum products in accordance with GB/T 508 and ASTM D482.
Q2: Which samples are not suitable for this instrument?
Products containing ash-forming additives, leaded lubricating oils, and used engine crankcase oils are not suitable.
Q3: How stable is the temperature control?
The digital controller ensures precise and stable temperature regulation with minimal overshoot.
Q4: Is the instrument suitable for continuous laboratory use?
Yes. It is designed with durable heating components and fire-resistant materials for long-term operation.
Q5: What type of laboratories typically use AZA1319?
Refineries, petrochemical labs, fuel testing facilities, and research institutions.
Related products
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
Standards Compliance
- ASTM D92 (Cleveland Open Cup)
FULLY AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1287
The AZA1287 Atmospheric Distillation Analyzer from AZA Lab is a fully automated, high-precision distillation testing system designed for petroleum laboratories that require ASTM D86-compliant determination of boiling range characteristics. Engineered for accuracy, repeatability, and high-throughput operation, the AZA1287 is ideal for testing gasoline, diesel, kerosene, jet fuel, light hydrocarbons, and other petroleum fractions.
Atmospheric distillation testing plays a critical role in evaluating fuel volatility, composition, and performance, directly influencing fuel quality, emissions compliance, and operational safety. The AZA1287 automates the complete distillation process—eliminating manual intervention, reducing operator error, and ensuring consistent, regulation-compliant results.
PENSKY–MARTENS CLOSED CUP FLASH POINT TESTER AZA1278
The AZA1278 Pensky–Martens Closed Cup Flash Point Tester is a high-precision, microcomputer-controlled instrument designed for accurate determination of flash points of petroleum products under controlled conditions.
Fully compliant with ASTM D93, the system supports Procedures A, B, and C, making it suitable for a wide range of fuels, lubricants, and viscous petroleum samples. It is engineered for reliability, repeatability, and safe laboratory operation.
Standards Compliance
- ASTM D93 (Pensky–Martens Closed Cup)
PETROLEUM PRODUCT DISTILLATION TESTER AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
SEMI-MANUAL DISTILLATION ANALYZER AZA1286
The Semi-Manual Distillation Analyzer (AZA1286) from AZA Lab is engineered to deliver accurate, repeatable, and ASTM D86-compliant atmospheric distillation testing for petroleum products. Designed to combine the robustness of manual operation with the precision of digital instrumentation, the AZA1286 is an ideal solution for educational institutions, QA/QC laboratories, and small- to mid-scale production facilities requiring reliable routine fuel analysis without the complexity of full automation.
This analyzer provides operators with direct control over heating, condensation, and receiver handling, while benefiting from digital temperature measurement, timing functions, and safety monitoring. The result is a cost-effective, dependable system that maintains compliance with international testing requirements.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
Rock
Aggregate
Cement
Concrete
Soil
Steel
Bitumen/Asphalt
Security Survey Equipment