GASOLINE OXIDATION STABILITY TESTER AZA1318
The AZA1318 Gasoline Oxidation Stability Tester from AZA Lab is a fully automated laboratory instrument designed to determine the oxidation stability of gasoline using the induction period method, in strict accordance with GB/T 8018-2015 and ASTM D525.
Oxidation stability testing is essential for evaluating a gasoline’s resistance to degradation during storage and use. By subjecting fuel samples to accelerated oxidation conditions, the AZA1318 accurately measures the induction period, providing reliable insight into fuel quality, shelf life, and compliance with regulatory specifications.
Description
Operating Principle
The AZA1318 measures the time required for gasoline to undergo rapid oxidation under controlled temperature and oxygen pressure conditions. The pressure drop inside the oxygen bomb is continuously monitored and recorded. The induction period is automatically determined when oxidation accelerates, ensuring objective, repeatable, and operator-independent results.
Key Features
Full Compliance with International Standards
-
Conforms to ASTM D525 and GB/T 8018-2015
-
Suitable for regulatory, refinery, and QC laboratories
Dual-System Architecture
-
Upper system: Industrial control PC for data processing and visualization
-
Lower system: Independent testing host for stable and precise control
-
Fully automated operation with minimal operator intervention
Water-Free Metal Bath Technology
-
Replaces traditional water bath with a metal heating bath
-
Eliminates water contamination and evaporation issues
-
Reduces maintenance and improves long-term reliability
High Accuracy Pressure Monitoring
-
Integrated oxygen bomb assembly with short oil–gas pressure pipeline
-
High-sealing manual needle valves improve measurement stability
-
Pressure resolution up to ±1 kPa
Energy-Efficient & Safe Design
-
Advanced thermal insulation reduces power consumption
-
External surfaces remain cooler, minimizing burn risk
User-Friendly Operation
-
Quick-release oxygen bomb brackets for easy handling
-
Simple setup and removal before and after testing
Real-Time Data Visualization
-
Live pressure curves for two oxygen bombs simultaneously
-
Automatic time-axis scaling for intuitive test monitoring
-
Clear identification of induction period endpoint
Applications
-
Petroleum refineries
-
Fuel quality control laboratories
-
Gasoline blending and storage facilities
-
Regulatory and inspection agencies
-
Research and fuel formulation laboratories
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1318 |
| Test Method | Induction Period (Oxidation Stability) |
| Standards | ASTM D525, GB/T 8018-2015 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Total Power Consumption | < 1000 W |
| Pressure Measurement Range | 0 – 1600 kPa |
| Pressure Accuracy | ± 1 kPa |
| Heating Mode | Water-free metal bath |
| Temperature Control Point | 100.0 °C ± 2 °C |
| Ambient Temperature | 15 – 28 °C |
| Relative Humidity | ≤ 85 % |
| Dimensions (L×W×H) | 300 × 420 × 280 mm |
| Net Weight | 23 kg |
Advantages of AZA1318
-
Fully automated software-controlled testing
-
Clean and maintenance-free metal bath system
-
Compact and robust construction
-
High accuracy and excellent repeatability
-
Ideal for routine QC and regulatory compliance testing
Model: AZA1318 – Gasoline Oxidation Stability Tester
Related products
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
CLEVELAND OPEN-CUP FLASH & FIRE POINT TESTER AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
FULLY AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1287
The AZA1287 Atmospheric Distillation Analyzer from AZA Lab is a fully automated, high-precision distillation testing system designed for petroleum laboratories that require ASTM D86-compliant determination of boiling range characteristics. Engineered for accuracy, repeatability, and high-throughput operation, the AZA1287 is ideal for testing gasoline, diesel, kerosene, jet fuel, light hydrocarbons, and other petroleum fractions.
Atmospheric distillation testing plays a critical role in evaluating fuel volatility, composition, and performance, directly influencing fuel quality, emissions compliance, and operational safety. The AZA1287 automates the complete distillation process—eliminating manual intervention, reducing operator error, and ensuring consistent, regulation-compliant results.
OIL & GAS SAMPLING CYLINDERS – DOUBLE & TRIPLE ENDED AZA1274A
AZA LAB’s Oil & Gas Sampling Cylinders and Gas Sampling Bombs (AZA1274A) are precision-engineered, high-pressure vessels designed for the safe, accurate collection and transport of liquid or gas samples in the oil, gas, and petrochemical sectors.Azalab
Crafted from premium stainless steel (SS 304/316) or corrosion-resistant Monel, these cylinders are available in single-, double-, and triple-ended configurations to support a wide range of sampling operations—from wellhead and refinery extraction to lab-based chromatographic analysis.aza
Each unit is subjected to rigorous hydrostatic and burst testing and complies with international certifications including TPED, CE, DOT, and ISO. Standard fittings include ¼″ or ½″ NPT ports, with options for dip tubes, safety relief valves, and custom end fittings.aza
Whether used offshore, in-process lines, or in research labs, the AZA1274A offers maximum safety, chemical compatibility, and sample integrity.
PRECISION AUTOMATED DISTILLATION ANALYZER AZA1281
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.