The AZA1318 Gasoline Oxidation Stability Tester from AZA Lab is a fully automated laboratory instrument designed to determine the oxidation stability of gasoline using the induction period method, in strict accordance with GB/T 8018-2015 and ASTM D525.
Oxidation stability testing is essential for evaluating a gasoline’s resistance to degradation during storage and use. By subjecting fuel samples to accelerated oxidation conditions, the AZA1318 accurately measures the induction period, providing reliable insight into fuel quality, shelf life, and compliance with regulatory specifications.
Description
Operating Principle
The AZA1318 measures the time required for gasoline to undergo rapid oxidation under controlled temperature and oxygen pressure conditions. The pressure drop inside the oxygen bomb is continuously monitored and recorded. The induction period is automatically determined when oxidation accelerates, ensuring objective, repeatable, and operator-independent results.
Key Features
Full Compliance with International Standards
-
Conforms to ASTM D525 and GB/T 8018-2015
-
Suitable for regulatory, refinery, and QC laboratories
Dual-System Architecture
-
Upper system: Industrial control PC for data processing and visualization
-
Lower system: Independent testing host for stable and precise control
-
Fully automated operation with minimal operator intervention
Water-Free Metal Bath Technology
-
Replaces traditional water bath with a metal heating bath
-
Eliminates water contamination and evaporation issues
-
Reduces maintenance and improves long-term reliability
High Accuracy Pressure Monitoring
-
Integrated oxygen bomb assembly with short oil–gas pressure pipeline
-
High-sealing manual needle valves improve measurement stability
-
Pressure resolution up to ±1 kPa
Energy-Efficient & Safe Design
-
Advanced thermal insulation reduces power consumption
-
External surfaces remain cooler, minimizing burn risk
User-Friendly Operation
-
Quick-release oxygen bomb brackets for easy handling
-
Simple setup and removal before and after testing
Real-Time Data Visualization
-
Live pressure curves for two oxygen bombs simultaneously
-
Automatic time-axis scaling for intuitive test monitoring
-
Clear identification of induction period endpoint
Applications
-
Petroleum refineries
-
Fuel quality control laboratories
-
Gasoline blending and storage facilities
-
Regulatory and inspection agencies
-
Research and fuel formulation laboratories
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1318 |
| Test Method | Induction Period (Oxidation Stability) |
| Standards | ASTM D525, GB/T 8018-2015 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Total Power Consumption | < 1000 W |
| Pressure Measurement Range | 0 – 1600 kPa |
| Pressure Accuracy | ± 1 kPa |
| Heating Mode | Water-free metal bath |
| Temperature Control Point | 100.0 °C ± 2 °C |
| Ambient Temperature | 15 – 28 °C |
| Relative Humidity | ≤ 85 % |
| Dimensions (L×W×H) | 300 × 420 × 280 mm |
| Net Weight | 23 kg |
Advantages of AZA1318
-
Fully automated software-controlled testing
-
Clean and maintenance-free metal bath system
-
Compact and robust construction
-
High accuracy and excellent repeatability
-
Ideal for routine QC and regulatory compliance testing
Model: AZA1318 – Gasoline Oxidation Stability Tester
Related products
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
CLEVELAND OPEN-CUP FLASH & FIRE POINT TESTER AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
PETROLEUM PRODUCT DISTILLATION TESTER AZA1284
The AZA1284 Manual Distillation Unit from AZA Lab is a high-precision, front-type petroleum distillation system engineered for accurate determination of distillation characteristics of petroleum products in accordance with ASTM D86 and GB/T 6536 test methods. Designed for laboratories that require reliable manual control with superior thermal stability, this unit delivers consistent, repeatable, and standards-compliant results.
With its dual-unit configuration, independently controlled constant-temperature baths, and continuously adjustable heating power, the AZA1284 offers exceptional flexibility and efficiency for routine quality control, inspection, and research applications.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
SEMI-MANUAL DISTILLATION ANALYZER AZA1286
The Semi-Manual Distillation Analyzer (AZA1286) from AZA Lab is engineered to deliver accurate, repeatable, and ASTM D86-compliant atmospheric distillation testing for petroleum products. Designed to combine the robustness of manual operation with the precision of digital instrumentation, the AZA1286 is an ideal solution for educational institutions, QA/QC laboratories, and small- to mid-scale production facilities requiring reliable routine fuel analysis without the complexity of full automation.
This analyzer provides operators with direct control over heating, condensation, and receiver handling, while benefiting from digital temperature measurement, timing functions, and safety monitoring. The result is a cost-effective, dependable system that maintains compliance with international testing requirements.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples
XRF SULFUR CONTENT TESTER AZA1300
The AZA Lab Sulfur Content Analyzer – AZA1300 is a state-of-the-art instrument designed for precise and rapid determination of sulfur content in petroleum, petrochemical, and coal chemical products. Based on the energy-dispersive X-ray fluorescence (EDXRF) principle, it integrates advanced electrical, mechanical, and microprocessor technologies to deliver high accuracy, reliability, and ease of operation.
Engineered to comply with ASTM D4294, GB/T 17040, SH/T0742, and GB/T11140 standards, the Model 1300 provides dependable measurement results with excellent repeatability and reproducibility. Its intelligent design ensures automatic corrections for environmental conditions such as temperature, pressure, and C/H ratio, making it a versatile solution for laboratories and production facilities alike.
Compact, user-friendly, and equipped with advanced safety features, the AZA1300 is an ideal tool for routine quality control, process monitoring, and research applications where sulfur determination is critical.