CLOUD & POUR POINT APPARATUS AZA1345A
The AZA1345A Cloud & Pour Point Apparatus is designed and manufactured in accordance with ASTM D97, ASTM D2500, ASTM D5853 standard test methods. The instrument is suitable for the determination of the Pour Point and Cloud Point of Petroleum Oils.
Description
I. MAIN TECHNICAL FEATURES
- Stainless Steel Working Table
The instrument is provided with a stainless steel working table and consists of two chambers — Chamber I and Chamber II. Each chamber is equipped with two cooling baths, with both cooling baths within each chamber maintained at the same temperature. All cooling baths can be used for determining Pour Point and Cloud Point.
- Efficient Refrigeration System
No external coolant is required in the chambers. The system provides rapid cooling and high cooling efficiency.
- Temperature Controller I controls the temperature of Chamber I.
- Temperature Controller II controls the temperature of Chamber II.
- Chamber II can achieve a minimum temperature of –70°C.
- Temperature control precision is ±1°C.
- Bench-Type Construction
The instrument features a compact bench-top structure with a concise design, making it easy to operate and convenient for laboratory use.
II. MAIN TECHNICAL SPECIFICATIONS
| PARAMETER | SPECIFICATION |
|---|---|
| Model | AZA1345A |
| Applications | Determination of Pour Point and Cloud Point of Petroleum Oils |
| Applicable Standards | ASTM D97, ASTM D2500, ASTM D5853, GB/T 3535, GB/T 6986 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Chamber I Temperature Range | Ambient to –51°C |
| Chamber I Temperature Control Precision | ±1°C |
| Chamber II Temperature Range | Ambient to –70°C |
| Chamber II Temperature Control Precision | ±1°C |
| Cooling Baths | 2 cooling baths in each chamber; temperature of baths within each chamber is the same |
| Refrigeration System | New-type refrigeration compressor |
| Coolant Requirement | No external coolant required |
| Ambient Temperature | ≤30°C |
| Relative Humidity | ≤85% |
| Maximum Power Consumption | 1500 W |
| Dimensions (W × D × H) | 800 × 580 × 400 mm |
| Construction | Bench-top type with stainless steel working table |
Related products
ADVANCED TRIAXIAL TEST SYSTEM (UU–CU–CD CAPABLE) AZA1296
The AZA LAB Advanced Triaxial Test System AZA1296 is a fully automated geotechnical laboratory testing system designed for accurate determination of soil shear strength and deformation characteristics under controlled stress and drainage conditions.
The system supports all major triaxial compression testing modes including:
- Unconsolidated Undrained (UU)
- Consolidated Undrained (CU)
- Consolidated Drained (CD)
Engineered for high-precision geotechnical analysis, the AZA1296 replicates in-situ soil stress conditions to evaluate soil stability, strength behavior, pore pressure response, and failure mechanisms under axial loading.
The system integrates servo-controlled loading, automatic pressure regulation, real-time pore pressure monitoring, automated data acquisition, and advanced software analysis, making it ideal for geotechnical laboratories, civil engineering projects, infrastructure development, research institutions, and academic applications.
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
CLEVELAND OPEN-CUP FLASH & FIRE POINT TESTER AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
OIL & GAS SAMPLING CYLINDERS – DOUBLE & TRIPLE ENDED AZA1274A
AZA LAB’s Oil & Gas Sampling Cylinders and Gas Sampling Bombs (AZA1274A) are precision-engineered, high-pressure vessels designed for the safe, accurate collection and transport of liquid or gas samples in the oil, gas, and petrochemical sectors.Azalab
Crafted from premium stainless steel (SS 304/316) or corrosion-resistant Monel, these cylinders are available in single-, double-, and triple-ended configurations to support a wide range of sampling operations—from wellhead and refinery extraction to lab-based chromatographic analysis.aza
Each unit is subjected to rigorous hydrostatic and burst testing and complies with international certifications including TPED, CE, DOT, and ISO. Standard fittings include ¼″ or ½″ NPT ports, with options for dip tubes, safety relief valves, and custom end fittings.aza
Whether used offshore, in-process lines, or in research labs, the AZA1274A offers maximum safety, chemical compatibility, and sample integrity.
PROGRAMMABLE FULLY-AUTOMATED CLEVELAND OPEN-CUP FLASH & FIRE POINT ANALYZER AZA1290
The AZA Lab Programmable Fully-Automated Cleveland Open-Cup Flash & Fire Point Analyzer AZA1290 is a high-precision petroleum testing instrument designed for fully automated determination of flash and fire points of petroleum products, lubricants, oils, bituminous materials, and combustible liquids in accordance with ASTM D92 and ISO 2592 standards.
Engineered for modern petroleum laboratories, the AZA1290 combines intelligent automation, advanced safety systems, precision temperature control, and comprehensive data management to deliver highly repeatable and operator-independent test results.
The system automates the complete testing cycle including heating control, ignition application, flash detection, fire point detection, result recording, and emergency shutdown, significantly improving laboratory efficiency, testing consistency, and operational safety.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples
Rock
Aggregate
Cement
Concrete
Soil
Steel
Bitumen/Asphalt
Security Survey Equipment
General Items