Aniline Point Tester AZA1328
The Aniline Point Tester (Model: AZA1328) from AZA Lab is a precision instrument designed for determining the aniline point and mixed aniline point of petroleum products and hydrocarbon solvents, in accordance with ASTM D611 Standard Test Methods. The aniline point is a critical parameter indicating the aromatic content and solvency properties of fuels and hydrocarbons. This instrument is widely used in laboratories, refineries, fuel quality control centers, and research facilities to ensure accurate characterization of product composition, compatibility, and performance.
The AZA1328 provides fully automated operation with integrated safety features, ensuring precise, reliable, and reproducible results while minimizing operator intervention.
Description
Key Applications & Features
-
High-Precision Measurement: Accurately determines the temperature at which aniline and the test sample are completely miscible, critical for evaluating aromatic content.
-
Mixed Aniline Point Testing: Can measure samples with aniline points below the crystallization temperature, providing enhanced analytical flexibility.
-
7-inch Color LCD Touch Screen: Modern, user-friendly interface displaying real-time data and operational status.
-
Imported Photoelectric Sensors: Ensures high repeatability and accuracy in detecting the miscibility endpoint.
-
Automatic One-Key Operation: Complete test cycle from heating, stirring, and detection to recording and printing is fully automated.
-
Over-Temperature Alarm: Stops the test and alerts the user if the sample temperature exceeds 170°C, enhancing safety.
-
Microprocessor-Controlled System: Handles heating, stirring, detection, data storage, printing, and shutdown for efficient workflow.
-
Data Management: Stores up to 200 records, allowing for historical data tracking and reporting.
-
Printing Capability: Built-in micro printer provides hard copies of test results for documentation and compliance.
-
Compact, Durable Design: Stainless steel body and high-quality components ensure long-term stability and minimal maintenance.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1328 |
| Temperature Control Range | Room temperature ~ 170°C |
| Temperature Accuracy | ±0.1°C |
| Heating Method | Electric heating rod |
| Heating Power | 60 W |
| Stirring Method | Motor-driven soft shaft |
| Detection Method | Photoelectric sensor |
| Storage Capacity | 200 records |
| Printing Method | Micro printer |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Optional Accessories | Stainless steel tray: 1 Glass test tube: 1 |
Applications in Industry
-
Fuel and Lubricant Quality Control: Evaluates aromatic content and compatibility.
-
Refineries: Assesses feedstock characteristics and process suitability.
-
Laboratories & Research: Supports analysis of hydrocarbon solvent properties and product formulation.
-
Regulatory Compliance: Ensures conformity with ASTM D611 and other industry standards.
The AZA1328 Aniline Point Tester is a highly reliable, fully automated, and user-friendly instrument that combines precision, safety, and efficiency, making it an essential tool for laboratories and industrial quality control operations.
Related products
APPARATUS FOR HYDROGEN SULFIDE TESTER AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314Â from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an Hâ‚‚S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
CLEVELAND OPEN-CUP FLASH & FIRE POINT TESTER AZA1292
The Cleveland Open Cup Flash Point Tester AZA1292 from AZA Lab is a reliable and precision-engineered laboratory instrument designed for determining the flash point and fire point of petroleum products in strict accordance with ASTM D92 and GB/T 3536-2008 standards. Engineered for accuracy, safety, and operational simplicity, the AZA1292 is an ideal solution for petroleum laboratories, refineries, inspection agencies, and quality control departments.
The instrument is suitable for testing petroleum products with flash points in the range of 79°C to 400°C, excluding fuel oils, and delivers consistent, repeatable, and standards-compliant results.
DIST-86S SEMI-AUTOMATED DISTILLATION ANALYZER AZA1283
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
PROGRAMMABLE FULLY-AUTOMATED CLEVELAND OPEN-CUP FLASH & FIRE POINT ANALYZER AZA1290
The AZA Lab Programmable Fully-Automated Cleveland Open-Cup Flash & Fire Point Analyzer AZA1290 is a high-precision petroleum testing instrument designed for fully automated determination of flash and fire points of petroleum products, lubricants, oils, bituminous materials, and combustible liquids in accordance with ASTM D92 and ISO 2592 standards.
Engineered for modern petroleum laboratories, the AZA1290 combines intelligent automation, advanced safety systems, precision temperature control, and comprehensive data management to deliver highly repeatable and operator-independent test results.
The system automates the complete testing cycle including heating control, ignition application, flash detection, fire point detection, result recording, and emergency shutdown, significantly improving laboratory efficiency, testing consistency, and operational safety.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples
Rock
Aggregate
Cement
Concrete
Soil
Steel
Bitumen/Asphalt
Security Survey Equipment