ASH DETERMINATION INSTRUMENT AZA1319
The AZA1319 Ash Determination Instrument from AZA Lab is a precision laboratory system designed for the accurate determination of ash content in petroleum products, in full compliance with GB/T 508 and ASTM D482 – Standard Test Method for Ash Content of Petroleum Products.
Engineered for reliability, temperature stability, and long service life, the AZA1319 is ideal for refineries, petrochemical laboratories, fuel testing facilities, and quality control departments where consistent ash measurement is essential for product evaluation and regulatory compliance.
Note: This instrument is not suitable for petroleum products containing ash-forming additives, lubricating oils with lead, or used engine crankcase oils, in accordance with the referenced test standards.
Description
Applications
-
Ash content determination in petroleum products
-
Refinery and petrochemical quality control
-
Fuel and oil testing laboratories
-
Research and analytical institutions
-
Compliance testing as per GB/T 508 and ASTM D482
Technical Specifications
| Component | Specification |
|---|---|
| Model | AZA1319 |
| Applicable Standards | GB/T 508, ASTM D482 |
| Box-Type Heating Furnace | |
| Power Supply | AC 220V ±10%, 50 Hz |
| Operating Temperature | 775 ±25 °C |
| Temperature Rise Time (Empty Furnace) | ≤ 50 minutes |
| Temperature Uniformity | ≤ 15 °C |
| Temperature Control Stand | |
| Power Supply | AC 220V ±10%, 50 Hz |
| Maximum Control Temperature | 1200 °C |
| Controller Type | Digital LED display |
| Electric Heating Plate | |
| Plate Diameter | Φ85 mm |
| Power Supply | AC 220V ±10%, 50 Hz |
| Rated Temperature | 400 °C |
| Heating Power Control | 1–6 grades, continuously adjustable |
Why Choose AZA1319?
-
Standards Compliant: Fully conforms to GB/T 508 and ASTM D482
-
Accurate & Reliable: Stable temperature control ensures repeatable ash determination
-
Compact & Durable: Fire-resistant construction with long service life
-
Efficient Operation: Fast heating and adjustable controls improve productivity
-
Laboratory-Ready: Ideal for routine QC and analytical testing environments
Frequently Asked Questions (FAQ)
Q1: What does the AZA1319 measure?
It determines the ash content in petroleum products in accordance with GB/T 508 and ASTM D482.
Q2: Which samples are not suitable for this instrument?
Products containing ash-forming additives, leaded lubricating oils, and used engine crankcase oils are not suitable.
Q3: How stable is the temperature control?
The digital controller ensures precise and stable temperature regulation with minimal overshoot.
Q4: Is the instrument suitable for continuous laboratory use?
Yes. It is designed with durable heating components and fire-resistant materials for long-term operation.
Q5: What type of laboratories typically use AZA1319?
Refineries, petrochemical labs, fuel testing facilities, and research institutions.
Related products
APPARATUS FOR SULFUR CONTENT IN LPG AZA1300A
Apparatus for Sulfur Content in LPG – AZA1300A
The AZA1300A Apparatus for Sulfur Content in LPG from Azalab is a high-performance analytical system designed for the accurate determination of total volatile sulfur in gaseous hydrocarbons and liquefied petroleum gases (LPG). Developed in strict accordance with ASTM D6667, this advanced instrument utilizes the Ultraviolet Fluorescence (UVF) detection method, delivering exceptional sensitivity, stability, and repeatability across a wide concentration range.
The AZA1300A is purpose-built for refineries, petrochemical plants, natural gas processing units, inspection laboratories, and quality assurance facilities, where precise sulfur measurement is critical for product quality, regulatory compliance, and environmental safety
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
Standards Compliance
- ASTM D92 (Cleveland Open Cup)
CLEVELAND OPEN CUP (D92) FLASH & FIRE POINT TESTER AZA1291
The Cleveland Open Cup Flash Point Tester AZA1291 from AZA Lab is a precision-engineered analytical instrument designed for accurate determination of flash point and fire point of petroleum products in full compliance with ASTM D92 and GB/T 3536-2008 standards. Built for reliability, safety, and intelligent operation, the AZA1291 is ideal for petroleum laboratories, refineries, inspection agencies, and quality control departments requiring repeatable and standards-compliant results.
The analyzer is suitable for samples with flash points ranging from 79°C to 400°C, covering a broad spectrum of petroleum products such as lubricating oils, transformer oils, diesel, heating oils, base oils, waxes, and other high-flash-point materials.
DIST-86S SEMI-AUTOMATED DISTILLATION ANALYZER AZA1283
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
SEDIMENT EXTRACTION TESTER AZA1313
The AZA1313 Sediment Extraction Tester from AZA Lab is a precision laboratory instrument engineered for the accurate determination of sediment content in crude oils and fuel oils using the extraction method specified in ASTM D473. Designed for reliability, consistency, and long-term laboratory use, this tester is an essential tool for petroleum refineries, inspection laboratories, and fuel quality control facilities.
Sediment content is a critical quality parameter that directly impacts storage stability, processing efficiency, pipeline integrity, and combustion performance of petroleum products. The AZA1313 ensures precise sediment measurement by extracting insoluble material using toluene, delivering dependable results across sediment concentrations ranging from 0.01% to 0.40% by mass, with capability for higher concentrations when required.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples