MERCURY ANALYZER (COLD VAPOR) AZA1344
The AZA1344 Mercury Analyzer (Cold Vapor) is designed for accurate and reliable laboratory determination of mercury. Its advanced microcontroller, coupled with a high-speed sensor, enables real-time plotting of mercury detection, allowing the user to compare standards and identify invalid readings.
With fully automated filter and pump control, the instrument provides configurable automatic reading schedules that control operations such as Auto Zero, Pump ON, and Maximum Reading Hold. This automation allows the analyst to focus on the analysis rather than the measurement process.
The AZA1344 is supplied with a laptop and dedicated Mercury Analysis Software as standard.
Description
Key Features
- Lower detection limit of 2.0 nanogram absolute
- Higher measurement range of >500 nanogram absolute
- Measurement capability up to 3.0 Abs
- Linear range >1.0 Abs
- Real-time peak detection and display through analysis software
- Automatic filter selection for zeroing and reading
- Pre-aligned optics for easy mercury lamp replacement
- Modular design to accommodate larger sample cells
- Fully automatic reading schedules with configurable time periods
- Automatic dark-current correction
- Proprietary glassware holder for space-saving installation
- Glassware holder can be mounted directly on the analyzer or placed nearby
Automatic Reading Schedule
The automatic reading schedule performs the following functions:
- Auto Zero / Auto Hundred
- Self Zero Check
- Start Reading
- Hold Maxima
- Start Pump to initiate mercury flow into the chamber
- Read complete measurement snapshot
- Stop Pump
- Automatically record maximum reading for further analysis
The autonomous application ensures that all sample and standard readings follow the same defined period and measurement process, thereby minimizing errors caused by variations in operating procedures.
Technical Specifications
| Parameter | Specification |
|---|---|
| Detection Limit | Lower detection: 2.0 Nanogram absolute |
| Higher Range | >500 Nanogram absolute |
| Sample Cell Length | 180.0 mm |
| Photometric System | Single Beam Optics |
| Photometric Range | Absorbance: 0.0 to 3.0 Abs |
| Light Source | Plug-in pre-aligned Mercury Lamp, 253.7 nm, with Quartz Window and Glass Protection |
| Detector | Silicon High-Performance UV Photodiode sourced from Hamamatsu Photonics |
| Output Device | USB through PC |
| Software | Mercury Analyzer Software, Microsoft Windows 7 and above |
| Power Requirements | 230 V / 50 Hz / 200 VA |
| Dimensions (Main Unit) | 510 W × 230 H × 350 D mm |
| Weight | Approx. 12 kg |
Standard Supply
- Mercury Analyzer
- Set of Reaction Vessels
- Magnetic Stirrer
- Stand for Vessel
- Laptop with Mercury Analysis Software
Applications
The AZA1344 is suitable for laboratory mercury analysis in samples requiring sensitive cold-vapor mercury determination, including water, environmental samples, industrial samples, and other compatible liquid samples.
Related products
APPARATUS FOR SULFUR CONTENT IN LPG AZA1300A
Apparatus for Sulfur Content in LPG – AZA1300A
The AZA1300A Apparatus for Sulfur Content in LPG from Azalab is a high-performance analytical system designed for the accurate determination of total volatile sulfur in gaseous hydrocarbons and liquefied petroleum gases (LPG). Developed in strict accordance with ASTM D6667, this advanced instrument utilizes the Ultraviolet Fluorescence (UVF) detection method, delivering exceptional sensitivity, stability, and repeatability across a wide concentration range.
The AZA1300A is purpose-built for refineries, petrochemical plants, natural gas processing units, inspection laboratories, and quality assurance facilities, where precise sulfur measurement is critical for product quality, regulatory compliance, and environmental safety
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
CLASSIC OPEN CUP FLASH POINT APPARATUS AZA1294
The AZA LAB Classic Open Cup Flash Point Apparatus AZA1294 is a reliable and cost-effective laboratory instrument designed for accurate determination of flash point temperature of petroleum products and combustible liquids using the Cleveland Open Cup (COC) method.
Manufactured in full compliance with ASTM D92 and ISO 2592 standards, the AZA1294 is ideally suited for petroleum laboratories, quality control facilities, educational institutions, refinery laboratories, and industrial safety testing environments where dependable flash point determination is essential.
The apparatus combines a classic manual testing approach with durable construction, stable heating performance, and straightforward operation, making it an excellent solution for routine laboratory testing, operator training, and quality assurance applications.
PROGRAMMABLE FULLY-AUTOMATED CLEVELAND OPEN-CUP FLASH & FIRE POINT ANALYZER AZA1290
The AZA Lab Programmable Fully-Automated Cleveland Open-Cup Flash & Fire Point Analyzer AZA1290 is a high-precision petroleum testing instrument designed for fully automated determination of flash and fire points of petroleum products, lubricants, oils, bituminous materials, and combustible liquids in accordance with ASTM D92 and ISO 2592 standards.
Engineered for modern petroleum laboratories, the AZA1290 combines intelligent automation, advanced safety systems, precision temperature control, and comprehensive data management to deliver highly repeatable and operator-independent test results.
The system automates the complete testing cycle including heating control, ignition application, flash detection, fire point detection, result recording, and emergency shutdown, significantly improving laboratory efficiency, testing consistency, and operational safety.
SEDIMENT EXTRACTION TESTER AZA1313
The AZA1313 Sediment Extraction Tester from AZA Lab is a precision laboratory instrument engineered for the accurate determination of sediment content in crude oils and fuel oils using the extraction method specified in ASTM D473. Designed for reliability, consistency, and long-term laboratory use, this tester is an essential tool for petroleum refineries, inspection laboratories, and fuel quality control facilities.
Sediment content is a critical quality parameter that directly impacts storage stability, processing efficiency, pipeline integrity, and combustion performance of petroleum products. The AZA1313 ensures precise sediment measurement by extracting insoluble material using toluene, delivering dependable results across sediment concentrations ranging from 0.01% to 0.40% by mass, with capability for higher concentrations when required.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.
Rock
Aggregate
Cement
Concrete
Soil
Steel
Bitumen/Asphalt
Security Survey Equipment