AUTOMATIC DISTILLATION APPARATUS AZA1341
The AZA1341 Automatic Distillation Apparatus from AZA LAB is a patented, fully automatic distillation system engineered for the precise determination of distillation characteristics of petroleum products at atmospheric pressure.
Designed to meet the stringent requirements of ASTM D86, ASTM D850, and ASTM D1078, the AZA1339 delivers exceptional accuracy, repeatability, and operational safety for routine and advanced petroleum testing. The system integrates advanced temperature control, high-precision liquid level tracking, and intelligent automatic correction algorithms to ensure reliable and reproducible results across a wide range of fuels and solvents.
With its intuitive 10.2-inch touch-screen interface, automated data processing, and comprehensive safety systems—including flame detection and nitrogen fire suppression—the AZA1339 is ideally suited for quality control laboratories, refineries, inspection agencies, and research institutions seeking a modern, compliant, and operator-friendly distillation solution.
Description
Standards & Compliance
-
ASTM D86 – Distillation of Petroleum Products at Atmospheric Pressure
-
ASTM D850 – Distillation of Industrial Aromatic Hydrocarbons
-
ASTM D1078 – Volatility of Petroleum Solvents
Key Features
-
Dual cooling system using compressor + semiconductor technology
-
Independent control of bath temperature and air chamber temperature
-
Large 10.2-inch touch-screen display for intuitive operation
-
Automatic detection and correction of ambient temperature and atmospheric pressure
-
Fully automatic judgment, calculation, correction, and recording of results
-
Imported high-precision liquid level tracking system (liquid level + lift)
-
Measuring cylinder resolution: 0.1 ml
-
Low-voltage electric heating furnace with ultra-fast thermal response
-
Automatic and stable control of condensation speed
-
Imported flame detection system for enhanced safety
-
High-accuracy PT100 glass temperature sensor (Germany) with multipoint calibration
-
Integrated automatic and manual nitrogen fire extinguishing system
Applications
-
Gasoline and automotive fuel testing
-
Aviation gasoline and jet/turbine fuel analysis
-
Diesel and marine fuel quality control
-
Biodiesel blends testing (up to B20)
-
Naphtha, kerosene, white spirits, and petroleum solvents
-
Refinery, inspection, and petroleum testing laboratories
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1341 |
| Power Supply | AC 220V ±10%, 50 Hz |
| Total Power | 2200 W |
| Bath Temperature Range | 0 – 60°C (±0.1°C) |
| Air Chamber Temperature | 10°C – Ambient (±0.5°C) |
| Steam Temperature Accuracy | ±0.1°C |
| Condensation Rate | 4 – 5 ml/min |
| Liquid Level Resolution | 0.1 ml |
| Safety System | Automatic & Manual Nitrogen Extinguishing |
| Operating Temperature | 5 – 40°C |
| Relative Humidity | ≤ 85% RH |
Operating Conditions
-
Laboratory bench installation
-
Vibration-free surface
-
Single-phase AC power supply
Supply & Support
-
Warranty: 12 months
-
After-Sales Support: Installation, calibration, and operator training
-
Software & Firmware: Continuous technical support
-
Packing: Export-grade wooden crate with shock protection
Related products
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
DIST-86S SEMI-AUTOMATED DISTILLATION ANALYZER AZA1283
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
PENSKY–MARTENS CLOSED CUP FLASH POINT TESTER AZA1278
The AZA1278 Pensky–Martens Closed Cup Flash Point Tester is a high-precision, microcomputer-controlled instrument designed for accurate determination of flash points of petroleum products under controlled conditions.
Fully compliant with ASTM D93, the system supports Procedures A, B, and C, making it suitable for a wide range of fuels, lubricants, and viscous petroleum samples. It is engineered for reliability, repeatability, and safe laboratory operation.
Standards Compliance
- ASTM D93 (Pensky–Martens Closed Cup)
PRECISION AUTOMATED DISTILLATION ANALYZER AZA1281
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
SEDIMENT EXTRACTION TESTER AZA1313
The AZA1313 Sediment Extraction Tester from AZA Lab is a precision laboratory instrument engineered for the accurate determination of sediment content in crude oils and fuel oils using the extraction method specified in ASTM D473. Designed for reliability, consistency, and long-term laboratory use, this tester is an essential tool for petroleum refineries, inspection laboratories, and fuel quality control facilities.
Sediment content is a critical quality parameter that directly impacts storage stability, processing efficiency, pipeline integrity, and combustion performance of petroleum products. The AZA1313 ensures precise sediment measurement by extracting insoluble material using toluene, delivering dependable results across sediment concentrations ranging from 0.01% to 0.40% by mass, with capability for higher concentrations when required.
SEMI AUTOMATED CLEVELAND OPEN CUPFLASH POINT ANALYZER AZA1289
The AZA1289 Semi-Automated Cleveland Open Cup Flash Point Analyzer from AZA Lab is engineered for accurate, repeatable determination of flash and fire points of petroleum products, lubricants, and other combustible liquids. Designed in full compliance with ASTM D92 and ISO 2592, this analyzer provides an optimal balance between automation, operator control, and cost efficiency.
The Cleveland Open Cup (COC) method is the globally accepted reference method for determining flash and fire points of materials with flash points above 79°C, making AZA1289 ideal for routine quality control, safety assessment, and regulatory testing in laboratory environments.
SEMI-MANUAL DISTILLATION ANALYZER AZA1286
The Semi-Manual Distillation Analyzer (AZA1286) from AZA Lab is engineered to deliver accurate, repeatable, and ASTM D86-compliant atmospheric distillation testing for petroleum products. Designed to combine the robustness of manual operation with the precision of digital instrumentation, the AZA1286 is an ideal solution for educational institutions, QA/QC laboratories, and small- to mid-scale production facilities requiring reliable routine fuel analysis without the complexity of full automation.
This analyzer provides operators with direct control over heating, condensation, and receiver handling, while benefiting from digital temperature measurement, timing functions, and safety monitoring. The result is a cost-effective, dependable system that maintains compliance with international testing requirements.
TAG CLOSED CUP FLASH POINT TESTER AZA1280
Standards Compliance
- ASTM D56 (Tag Closed Cup Method)
Measurement Capability
- Flash Point Range: –40°C to 70°C
- Suitable for liquids with flash points below 93°C
- Designed for low viscosity and highly volatile samples