CLEVELAND OPEN CUP (D92) FLASH & FIRE POINT TESTER AZA1291
The Cleveland Open Cup Flash Point Tester AZA1291 from AZA Lab is a precision-engineered analytical instrument designed for accurate determination of flash point and fire point of petroleum products in full compliance with ASTM D92 and GB/T 3536-2008 standards. Built for reliability, safety, and intelligent operation, the AZA1291 is ideal for petroleum laboratories, refineries, inspection agencies, and quality control departments requiring repeatable and standards-compliant results.
The analyzer is suitable for samples with flash points ranging from 79°C to 400°C, covering a broad spectrum of petroleum products such as lubricating oils, transformer oils, diesel, heating oils, base oils, waxes, and other high-flash-point materials.
Description
High-Accuracy Cleveland Open Cup Testing
Flash point and fire point testing are critical parameters for evaluating the flammability, storage safety, transportation classification, and regulatory compliance of petroleum products. The AZA1291 employs the Cleveland Open Cup (COC) method, which is internationally recognized for high-temperature flash and fire point determination.
The system features precise temperature ramp control, ensuring smooth heating in accordance with ASTM D92 requirements. Automatic detection of flash and sustained fire ensures reliable identification of test endpoints with minimal operator intervention.
Advanced Touchscreen & Intelligent Control
At the core of the AZA1291 is an 8-inch high-definition IPS touchscreen, powered by a 32-bit ARM processor and a high-precision AD acquisition chip. This advanced control architecture allows:
-
Real-time temperature curve visualization
-
Automatic data recording and storage
-
Intuitive menu navigation
-
Clear display of flash and fire point results
The intelligent control system enhances repeatability while simplifying daily operation, even for high-throughput laboratory environments.
Automatic Atmospheric Pressure Compensation
To ensure maximum accuracy under varying environmental conditions, the AZA1291 is equipped with automatic atmospheric pressure measurement and correction. Flash point values are automatically adjusted to standard pressure conditions, reducing calculation errors and improving compliance with international testing standards.
Smart Connectivity & Data Management
The analyzer features built-in Bluetooth connectivity, enabling seamless wireless transmission of test results to compatible devices for viewing, documentation, and reporting. This feature improves workflow efficiency and reduces manual data transcription.
Additionally, the system supports:
-
Remote software upgrades
-
Intelligent fault diagnostics
-
Early warning alerts
-
Performance status monitoring
These smart features ensure long-term reliability and reduced downtime.
Enhanced Safety & Fire Control System
Safety is a critical consideration in high-temperature flash point testing. The AZA1291 incorporates:
-
Electronic ignition with gas flame, ensuring stable and repeatable ignition
-
Automatic fire extinguishing system that activates immediately after fire point detection
-
Manual fire extinguishing capability for added operator control
These features significantly reduce operator exposure to open flames while maintaining precise fire point determination.
Durable Design for Laboratory & Industrial Use
The AZA1291 is constructed for long-term operation in demanding laboratory and refinery environments. Its compact benchtop design minimizes space requirements while maintaining robust thermal stability and mechanical durability.
The instrument operates reliably under standard laboratory conditions and is designed for continuous quality control and R&D testing.
Key Applications
-
Petroleum and lubricant testing laboratories
-
Oil refineries and petrochemical plants
-
Transformer oil and insulating fluid analysis
-
Fuel storage and transportation safety evaluation
-
Quality control and regulatory compliance testing
-
Research and academic laboratories
Key Features
-
Cleveland Open Cup flash & fire point tester
-
Fully compliant with ASTM D92 and GB/T 3536-2008
-
Flash point range: 79°C to 400°C
-
8-inch IPS touchscreen with real-time curve display
-
Automatic atmospheric pressure correction
-
Bluetooth wireless data transmission
-
Electronic gas ignition system
-
Automatic and manual fire extinguishing
-
Intelligent diagnostics and remote software updates
-
High accuracy, repeatability, and operator safety
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1291 |
| Test Method | Cleveland Open Cup (ASTM D92, GB/T 3536-2008) |
| Flash Point Range | 79°C to 400°C |
| Power Supply | AC 220V ±10%, 50 Hz |
| Maximum Power Consumption | 700 W |
| Heating Rate | 14–17°C/min (initial), 5–6°C/min (after preset FP +20°C) |
| Ignition Method | Electronic ignition with gas flame |
| Data Transmission | Bluetooth |
| Fire Extinguishing | Automatic after fire point detection + manual option |
| Ambient Temperature | 15–35°C |
| Relative Humidity | ≤85% |
| Dimensions (L×W×H) | 510 × 320 × 330 mm |
| Net Weight | 20 kg |
Frequently Asked Questions (FAQ)
Q1: Which standards does the AZA1291 comply with?
It fully complies with ASTM D92 and GB/T 3536-2008 standards for Cleveland Open Cup flash and fire point testing.
Q2: What products can be tested using this instrument?
It is suitable for lubricating oils, transformer oils, diesel, heating oils, waxes, base oils, and other high-flash-point petroleum products.
Q3: Is atmospheric pressure correction automatic?
Yes. The system automatically measures and corrects for atmospheric pressure to ensure accurate results.
Q4: How is operator safety ensured?
The analyzer includes electronic ignition, automatic fire extinguishing, manual override, intelligent diagnostics, and stable temperature control.
Q5: Can test data be transferred wirelessly?
Yes. Built-in Bluetooth enables wireless viewing and transfer of test data.
Model: AZA1291 – Cleveland Open Cup Flash & Fire Point Tester
Additional information
| Test Method |
Cleveland Open Cup (ASTM D92) |
|---|---|
| Temperature Range |
Ambient to 400°C |
| Sample Cup Material |
Stainless Steel |
| Heating System |
Microprocessor-controlled |
You may also like…
ADVANCED TRIAXIAL TEST SYSTEM (UU–CU–CD CAPABLE) AZA1296
The AZA LAB Advanced Triaxial Test System AZA1296 is a fully automated geotechnical laboratory testing system designed for accurate determination of soil shear strength and deformation characteristics under controlled stress and drainage conditions.
The system supports all major triaxial compression testing modes including:
- Unconsolidated Undrained (UU)
- Consolidated Undrained (CU)
- Consolidated Drained (CD)
Engineered for high-precision geotechnical analysis, the AZA1296 replicates in-situ soil stress conditions to evaluate soil stability, strength behavior, pore pressure response, and failure mechanisms under axial loading.
The system integrates servo-controlled loading, automatic pressure regulation, real-time pore pressure monitoring, automated data acquisition, and advanced software analysis, making it ideal for geotechnical laboratories, civil engineering projects, infrastructure development, research institutions, and academic applications.
AIR BAG TRAINER AZA1246
The AZA1246 AZALAB Air Bag Trainer is a comprehensive educational training platform designed to demonstrate the structure, operation, diagnostics, and fault analysis of modern automotive airbag systems, also known as Supplemental Restraint Systems (SRS). Built using OEM automotive components, this trainer delivers a realistic learning experience while maintaining complete operational safety.
This system is ideally suited for automotive engineering colleges, ITIs, polytechnic institutes, vocational training centers, and service technician programs, enabling both theoretical instruction and hands-on diagnostics practice.
ALTERNATOR TRAINER AZA1247
The AZA1247 AZALAB Alternator Trainer is a hands-on automotive electrical training system designed to demonstrate the working principles, construction, and diagnostics of an automotive alternator with external voltage regulation. Built using OEM automotive components, this trainer provides a realistic and safe learning platform for students, technicians, and trainees to understand vehicle charging systems in depth.
This system is ideal for automotive engineering institutes, ITIs, polytechnics, vocational training centers, and service technician programs, supporting both theoretical instruction and practical experimentation.
ARC WELDING MACHINE AZA1234
The AZA1234 Arc Welding Machine by A Z A Lab is a high-performance industrial welding solution engineered for demanding fabrication, maintenance, and structural welding applications. Designed using advanced inverter technology, this machine delivers superior arc stability, high efficiency, and reliable welding performance across a wide range of electrode types and materials.
With an inverter frequency of up to 20 kHz, the AZA1234 ensures fast dynamic response, reduced spatter, and excellent weld bead appearance. Its robust electrical design supports a high duty cycle, allowing continuous operation under heavy loads while maintaining consistent welding output—even with output cable lengths of up to 100 meters.
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
Related products
APPARATUS FOR HYDROGEN SULFIDE TESTER AZA1314
The Apparatus for Hydrogen Sulfide Tester AZA1314 from AZA Lab conforms to the ASTM D7621 Standard Test Method for the determination of hydrogen sulfide in fuel oils by rapid liquid phase extraction.
In this method, a weighed test sample is placed into a heated vessel containing a diluent base oil, where air is bubbled through to extract hydrogen sulfide gas. The extracted gas is then directed, via a vapor phase processor (Procedure A), to an H₂S-specific electrochemical detector, which measures its concentration in air and calculates the amount in the liquid phase in mg/kg. For Procedure B, the use of a filter cartridge is not required.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1279
Standards Compliance
- ASTM D92 (Cleveland Open Cup)
GASOLINE OXIDATION STABILITY TESTER AZA1318
The AZA1318 Gasoline Oxidation Stability Tester from AZA Lab is a fully automated laboratory instrument designed to determine the oxidation stability of gasoline using the induction period method, in strict accordance with GB/T 8018-2015 and ASTM D525.
Oxidation stability testing is essential for evaluating a gasoline’s resistance to degradation during storage and use. By subjecting fuel samples to accelerated oxidation conditions, the AZA1318 accurately measures the induction period, providing reliable insight into fuel quality, shelf life, and compliance with regulatory specifications.
LIQUID PETROLEUM PRODUCTS HYDROCARBON TESTER AZA1316
The AZA1316 Liquid Petroleum Products Hydrocarbon Analyzer from AZA Lab is a specialized laboratory instrument designed for the quantitative determination of aromatic hydrocarbons, olefins, and saturated hydrocarbons in liquid petroleum fractions. This analyzer delivers accurate, reliable, and repeatable results, making it an essential tool for petroleum refining, fuel quality control, regulatory compliance, and research laboratories.
With its ready-to-use vertical design, advanced detection system, and automated cleaning features, the AZA1316 ensures efficient operation with minimal operator intervention while maintaining high analytical precision.
SEMI-AUTOMATED ABEL FLASH POINT ANALYZER AZA1275
The AZA1275 AutoFlash Abel Flash Point Tester from AZA Lab is a semi-automated, microcontroller-based Abel closed cup analyzer designed for precise determination of flash points of low-flash combustible liquids. Engineered to comply with IP 170, ISO 13736, and IS 1448 (Part 20), AZA1275 ensures reliable, repeatable, and regulation-compliant testing for petroleum, chemical, and industrial laboratories.
Equipped with an integrated Windows-based PC interface, AZA1275 delivers intuitive operation, automated flash detection, controlled heating, and comprehensive fault diagnostics. The system is ideal for laboratories that require accuracy, safety, and efficiency without the cost complexity of fully automated systems.
SEMI-AUTOMATED ATMOSPHERIC DISTILLATION ANALYZER AZA1285
The AZA1285 Semi-Automated Atmospheric Distillation Analyzer is a precision-engineered laboratory instrument designed for determining the distillation characteristics of petroleum products, fuels, solvents, and volatile organic liquids under atmospheric conditions. Developed for accurate boiling-range profiling and dependable laboratory performance, the AZA1285 combines manual operational flexibility with intelligent thermal regulation for highly repeatable and standards-compliant testing.
The system features a low-voltage manually adjustable heater integrated with PID-controlled condenser and receiver sections, ensuring stable distillation rates and accurate thermal management throughout the test cycle. A closed-loop, CFC-free refrigeration system provides efficient condensation without requiring external cooling water, while an integrated inert gas purge system enhances operator safety and minimizes oxidation risks during testing.
STAINLESS STEEL COC CLEVELAND OPEN CUP FLASH POINT ANALYZER AZA1293
The AZA1293 Flash Point Analyzer from AZA Lab is a precision-engineered instrument designed for accurate determination of the flash point of flammable and combustible liquids using the Cleveland Open Cup (COC) method. Manufactured with high-grade stainless steel construction, this analyzer ensures excellent thermal stability, long service life, and consistent test performance even under demanding laboratory conditions.
Fully compliant with ASTM D92, the AZA1293 is an essential laboratory tool for petrochemical laboratories, refineries, lubricant manufacturers, fuel testing facilities, and industrial R&D centers where reliable flash point determination is critical for safety classification and quality assurance.
TAN & TBN (KARL FISCHER MOISTURE TITRATOR) TESTER AZA1315
The AZA1315 Karl Fischer Moisture Titrator from AZA Lab is a high-precision analytical instrument designed for the determination of trace water content in liquid petroleum products, lubricating oils, additives, and related materials using the Coulometric Karl Fischer method.
The instrument is designed and manufactured in full compliance with international and industry standards including GB/T 7600, SH/T 0246, ASTM D1533, and ASTM D6304, ensuring accurate, repeatable, and globally accepted moisture analysis results.
Powered by advanced microcomputer control technology, the AZA1315 delivers fast testing, high sensitivity, and stable performance. Its touch-screen LCD interface, fully automated titration, and built-in thermal printer make it an ideal solution for laboratories and industrial quality control environments requiring precise moisture determination.