AZA LAB Classic Open Cup Flash Point Apparatus AZA1294

The AZA1294 Classic Open Cup Flash Point Apparatus from AZA LAB is a reliable and cost-effective laboratory instrument designed for the determination of flash point temperature of petroleum products and flammable liquids using the Cleveland Open Cup (COC) method, in full compliance with ASTM D92 and ISO 2592 standards.

This apparatus is widely used in petroleum testing laboratories, quality control facilities, educational institutions, and fuel safety assessment centers, where accurate flammability classification is essential.

Description

Description

Purpose of Flash Point Testing

Flash point testing identifies the lowest temperature at which vapors from a liquid ignite momentarily when exposed to an ignition source. This critical parameter is used to:

  • Classify flammable and combustible liquids

  • Determine safe storage and transportation conditions

  • Evaluate fire and explosion hazards

  • Meet regulatory and insurance requirements

The open cup method provides conservative and realistic results by allowing vapors to disperse freely, closely simulating real-world spill and exposure conditions.


ASTM D92 Cleveland Open Cup Method

The AZA1294 employs the Cleveland Open Cup (COC) test method, recommended for petroleum products with higher flash points, such as:

  • Lubricating oils

  • Diesel fuels

  • Heavy oils

  • Biofuels

  • Transformer and insulating oils

The apparatus consists of a polished brass test cup placed on a controlled heating block. The temperature of the sample is increased at a standardized rate while a manually controlled test flame is passed over the sample surface at defined intervals until flash is observed.


Robust & User-Friendly Design

The AZA1294 features a classic, operator-friendly design that emphasizes accuracy, safety, and repeatability:

  • Thermostatically controlled heating unit for smooth temperature ramp

  • Clear visibility zone for easy flame observation

  • Manual flame applicator for controlled ignition

  • Thermometer port compatible with ASTM-certified thermometers

Its straightforward operation makes it particularly suitable for training laboratories and routine QC testing, where understanding the test process is as important as the result itself.


Why Choose AZA1294?

  • Fully compliant with ASTM D92 & ISO 2592

  • Accurate and repeatable flash point determination

  • Ideal for petroleum products, lubricants, and biofuels

  • Manual operation for hands-on control and learning

  • Durable construction with long service life

  • Cost-effective alternative to fully automated analyzers

This apparatus is trusted in oil refineries, fuel blending facilities, transportation safety labs, and academic institutions worldwide.


Key Features

  • Cleveland Open Cup flash point apparatus

  • ASTM D92 standard compliance

  • Polished brass test cup

  • Manual test flame ignition

  • Controlled and consistent heating rate

  • Suitable for high flash point petroleum products

  • Compact, bench-top laboratory design

  • Low maintenance and easy calibration


Technical Specifications

Parameter Specification
Model AZA1294
Test Method Cleveland Open Cup (ASTM D92, ISO 2592)
Temperature Range Ambient to 400 °C
Heating Rate 5–6 °C/min (standard compliant)
Test Cup Material Polished Brass
Ignition Source Manually controlled test flame
Thermometer Compatibility ASTM E2251 glass thermometer
Power Supply 230 V ±10%, 50/60 Hz
Dimensions Approx. 300 × 200 × 220 mm
Application Areas Petroleum labs, QC testing, education

Frequently Asked Questions (FAQ)

Q1: What is the main purpose of the AZA1294?
It is used to determine the flash point of petroleum products and flammable liquids using the Cleveland Open Cup method.

Q2: Why is the open cup method preferred for some products?
It allows free vapor exposure, offering conservative results that better represent real-world spill conditions.

Q3: Is the AZA1294 compliant with ASTM standards?
Yes, it is fully compliant with ASTM D92 and ISO 2592.

Q4: Can it be used for non-petroleum liquids?
Yes, it can be used for biodiesel, synthetic oils, and selected industrial solvents.

Q5: Is special training required?
Only basic laboratory training is needed. The manual design makes operation intuitive and educational


Model: AZA1294 – Classic Open Cup Flash Point Apparatus (ASTM D92)

Additional information

Additional information

Method Supported

Open Cup (ASTM D92, ISO 2592)

Sample Cup

Stainless steel, removable

Heating Rate

Adjustable, typically 5–6°C per minute

Ignition Source

Manual flame / Electric igniter (optional)