GASOLINE OXIDATION STABILITY TESTER AZA1318
The AZA1318 Gasoline Oxidation Stability Tester from AZA Lab is a fully automated laboratory instrument designed to determine the oxidation stability of gasoline using the induction period method, in strict accordance with GB/T 8018-2015 and ASTM D525.
Oxidation stability testing is essential for evaluating a gasoline’s resistance to degradation during storage and use. By subjecting fuel samples to accelerated oxidation conditions, the AZA1318 accurately measures the induction period, providing reliable insight into fuel quality, shelf life, and compliance with regulatory specifications.
Description
Operating Principle
The AZA1318 measures the time required for gasoline to undergo rapid oxidation under controlled temperature and oxygen pressure conditions. The pressure drop inside the oxygen bomb is continuously monitored and recorded. The induction period is automatically determined when oxidation accelerates, ensuring objective, repeatable, and operator-independent results.
Key Features
Full Compliance with International Standards
-
Conforms to ASTM D525 and GB/T 8018-2015
-
Suitable for regulatory, refinery, and QC laboratories
Dual-System Architecture
-
Upper system: Industrial control PC for data processing and visualization
-
Lower system: Independent testing host for stable and precise control
-
Fully automated operation with minimal operator intervention
Water-Free Metal Bath Technology
-
Replaces traditional water bath with a metal heating bath
-
Eliminates water contamination and evaporation issues
-
Reduces maintenance and improves long-term reliability
High Accuracy Pressure Monitoring
-
Integrated oxygen bomb assembly with short oil–gas pressure pipeline
-
High-sealing manual needle valves improve measurement stability
-
Pressure resolution up to ±1 kPa
Energy-Efficient & Safe Design
-
Advanced thermal insulation reduces power consumption
-
External surfaces remain cooler, minimizing burn risk
User-Friendly Operation
-
Quick-release oxygen bomb brackets for easy handling
-
Simple setup and removal before and after testing
Real-Time Data Visualization
-
Live pressure curves for two oxygen bombs simultaneously
-
Automatic time-axis scaling for intuitive test monitoring
-
Clear identification of induction period endpoint
Applications
-
Petroleum refineries
-
Fuel quality control laboratories
-
Gasoline blending and storage facilities
-
Regulatory and inspection agencies
-
Research and fuel formulation laboratories
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AZA1318 |
| Test Method | Induction Period (Oxidation Stability) |
| Standards | ASTM D525, GB/T 8018-2015 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Total Power Consumption | < 1000 W |
| Pressure Measurement Range | 0 – 1600 kPa |
| Pressure Accuracy | ± 1 kPa |
| Heating Mode | Water-free metal bath |
| Temperature Control Point | 100.0 °C ± 2 °C |
| Ambient Temperature | 15 – 28 °C |
| Relative Humidity | ≤ 85 % |
| Dimensions (L×W×H) | 300 × 420 × 280 mm |
| Net Weight | 23 kg |
Advantages of AZA1318
-
Fully automated software-controlled testing
-
Clean and maintenance-free metal bath system
-
Compact and robust construction
-
High accuracy and excellent repeatability
-
Ideal for routine QC and regulatory compliance testing
Model: AZA1318 – Gasoline Oxidation Stability Tester
Related products
AUOTFLASH AUTOMATED ABEL FLASH POINT ANALYZER AZA1277
The AutoFlash-1277 (Model: AZA1277) from AZA Lab is a fully automated, microcontroller-based Abel Flash Point Analyzer designed for accurate, safe, and repeatable determination of flash points of combustible liquids. Engineered to meet stringent international testing requirements, this advanced instrument conforms to IP 170, ISO 13736, and IS 1448 (Part 20) standards.
Covering a standard temperature range of –30°C to 70°C, extendable up to 110°C, the AZA1277 is ideally suited for laboratories involved in petroleum testing, petrochemical quality control, fuels research, and regulatory compliance.
AUTODIST-86 GLASS DISTILLATION UNITAZA1282
The AutoDist-86 Glass Distillation Unit (Model AZA1282) is a high-performance laboratory water distiller designed for the continuous production of high-purity distilled water.
Constructed entirely from borosilicate glass 3.3, the unit ensures zero metallic contamination, excellent thermal resistance, and long operational life. It is ideal for laboratories requiring consistent, low-conductivity distilled water for analytical, pharmaceutical, and research applications.Distillation Performance
- Distillate Output: Up to 4 L/hour (±10%)
- Suitable for routine and medium-scale laboratory demand
- Efficient removal of:
- Dissolved salts
- Heavy metals
- Organic/inorganic impurities
- Microbial contaminants
AUTOMATED CLEVELAND OPEN CUP FLASH & FIRE POINT ANALYZER AZA1276
The AutoFlash1276 (Model: AZA1276) from AZA Lab is a fully automated, microcontroller-based Cleveland Open Cup (COC) Flash and Fire Point Analyzer designed for high-temperature petroleum testing applications. Engineered for accuracy, safety, and regulatory compliance, the AZA1276 delivers reliable flash and fire point determination for materials with flash points above 79 °C up to 400 °C.
Complying with ASTM D92, ISO 2592, IS 1448 (Part 69), and IP 36, this advanced analyzer is ideal for laboratories and industrial environments where repeatability, operator safety, and international acceptance are critical.
DIST-86S SEMI-AUTOMATED DISTILLATION ANALYZER AZA1283
Standards Compliance
- ASTM D86
- ISO 3405
- IP 123
DIST-86S SEMI-AUTOMATED DISTILLATION TESTER AZA1288
The AZA Lab Dist-86S Semi-Automated Distillation Tester AZA1288 is a precision-engineered petroleum testing instrument designed for accurate determination of the distillation characteristics of petroleum products and volatile organic liquids in full accordance with ASTM D86 standards.
Built for laboratories requiring dependable performance, repeatability, and operational safety, the AZA1288 combines intelligent semi-automation with operator flexibility. The system is ideally suited for petroleum refineries, fuel inspection laboratories, aviation fuel testing facilities, research institutions, petrochemical plants, and educational laboratories.
The instrument utilizes PID-controlled heating technology, precision temperature monitoring, and an integrated condenser cooling system to ensure highly stable distillation conditions and accurate boiling point determination across a wide range of petroleum fractions.
PENSKY–MARTENS CLOSED CUP FLASH POINT TESTER AZA1278
The AZA1278 Pensky–Martens Closed Cup Flash Point Tester is a high-precision, microcomputer-controlled instrument designed for accurate determination of flash points of petroleum products under controlled conditions.
Fully compliant with ASTM D93, the system supports Procedures A, B, and C, making it suitable for a wide range of fuels, lubricants, and viscous petroleum samples. It is engineered for reliability, repeatability, and safe laboratory operation.
Standards Compliance
- ASTM D93 (Pensky–Martens Closed Cup)
SEDIMENT EXTRACTION TESTER AZA1313
The AZA1313 Sediment Extraction Tester from AZA Lab is a precision laboratory instrument engineered for the accurate determination of sediment content in crude oils and fuel oils using the extraction method specified in ASTM D473. Designed for reliability, consistency, and long-term laboratory use, this tester is an essential tool for petroleum refineries, inspection laboratories, and fuel quality control facilities.
Sediment content is a critical quality parameter that directly impacts storage stability, processing efficiency, pipeline integrity, and combustion performance of petroleum products. The AZA1313 ensures precise sediment measurement by extracting insoluble material using toluene, delivering dependable results across sediment concentrations ranging from 0.01% to 0.40% by mass, with capability for higher concentrations when required.
XRF SULFUR CONTENT TESTER AZA1300
The AZA Lab Sulfur Content Analyzer – AZA1300 is a state-of-the-art instrument designed for precise and rapid determination of sulfur content in petroleum, petrochemical, and coal chemical products. Based on the energy-dispersive X-ray fluorescence (EDXRF) principle, it integrates advanced electrical, mechanical, and microprocessor technologies to deliver high accuracy, reliability, and ease of operation.
Engineered to comply with ASTM D4294, GB/T 17040, SH/T0742, and GB/T11140 standards, the Model 1300 provides dependable measurement results with excellent repeatability and reproducibility. Its intelligent design ensures automatic corrections for environmental conditions such as temperature, pressure, and C/H ratio, making it a versatile solution for laboratories and production facilities alike.
Compact, user-friendly, and equipped with advanced safety features, the AZA1300 is an ideal tool for routine quality control, process monitoring, and research applications where sulfur determination is critical.