Semi‑Automated Twin Distillation Analyzer (AZA 1284)
- ASTM D86, D850, D1078, ISO 3405, IP 123, IP 195
Why Choose Semi‑Automated Twin Distillation Analyzer?
- Twin simultaneous distillation boosts laboratory throughput
- Combines semi-automation with manual fine control for flexibility
- Includes comprehensive safety features and PID-regulated temperature control
- Modular accessories allow tailored configurations based on lab needs
ABEL CLOSED CUP FLASH POINT TESTER (AZA 1280)
Advanced Triaxial Test System (UU–CU–CD Capable) (AZA 1296)
The Advance Triaxial UU-CU-CD Test System is a high-precision, fully automated solution designed for conducting a wide range of geotechnical triaxial tests on both undisturbed and remolded soil samples. This advanced system enables accurate execution of Unconsolidated Undrained (UU), Consolidated Drained (CD), and Consolidated Undrained (CU) tests in full compliance with international testing standards such as ASTM D2850, ASTM D4767, and BS 1377.
Built for reliability, repeatability, and lab productivity, the system seamlessly integrates automatic pressure control, load application, data acquisition, and result reporting into a single cohesive unit—eliminating manual errors and saving time during extended testing cycles.
AutoDist‑86 Glass Distillation (AZA 1282)
AutoFlash – Automated Abel Flash Point Analyzer( AZA 1277)
AZA Lab's AutoFlash-1277 is a fully automated, microcontroller-based Abel Flash Point Analyzer designed to accurately determine the flash points of combustible liquids. Conforming to IP 170, ISO 13736, and IS 1448 (P:20) standards, it ensures precise and safe analysis of samples in the temperature range of -30°C to 70°C, extendable up to 110°C.
Equipped with a built-in PC and touchscreen display, the AutoFlash-170 delivers intuitive operation, automated calibration, advanced ignition options, and rapid heating procedures for high-efficiency testing. Ideal for laboratories, petrochemical industries, and quality control applications, this standalone unit streamlines the testing process with enhanced accuracy, safety interlocks, and programmable procedures.
AutoFlash- Automated ABEL Flash Point Analyzer (AZA 1278)
The AutoFlash-1278Â is a fully automated, microcontroller-based ABEL Flash Point Analyzer, specifically designed for the determination of the flash point of combustible liquids. It conforms to IP 170, ISO 13736, and IS 1448 (P:20) standards, ensuring high precision and repeatability.
It determines flash points within a temperature range of -30°C to 70°C, and can be extended to 110°C for specialized applications. The device is ideal for laboratories handling petroleum products, quality control, R&D, and regulatory compliance.
AutoFlash-92 – Automated Cleveland Open Cup Flash Point Analyzer(AZA 1292)
Standards Compliance
-
ASTM D92
-
ISO 2592
-
IS 1448 (P:69)
-
IP 36
Parameter | Specification |
---|---|
Auto Calibration | Before each run, no calibration device needed |
Sample Temp. | PT100 Class A, SS sheath; 0 to 400°C, resolution 0.1°C |
Bath Temp. | PT100 Class A, Disk Type; 0 to 500°C |
Flash Detection | Ionization Ring |
Fire Detection | Thermal Sensor |
Ambient Pressure | Built-in sensor; 700–1100 hPa (500–800 mmHg) |
Automated Cleveland Open Cup Flash Point & Fire Point Analyzer(AZA 1276)
The AZA Lab AutoFlash-1276 (v2.0) is a fully programmable, microcontroller-based standalone Cleveland Open Cup Flash Point Analyzer, designed to comply with ASTM D92, ISO 2592, IS 1448 (P:69), and IP 36 standards.
It is ideal for testing petroleum products, especially viscous materials, with flash points above 79°C and below 400°C (excluding fuel oils). The analyzer also determines the fire point—the temperature at which the sample sustains combustion for at least 5 seconds.
AUTOMATED CLEVELAND OPEN CUP FLASH POINT ANALYZER(AZA 1279)
AutoFlash-1278 is a programmable, fully automated, microcontroller-based standalone Cleveland Open Cup Flash Point Analyzer conforming to standards:
ASTM D92, ISO 2592, IS 1448 (P:69), IP 36.
It is suitable for all petroleum products, especially viscous materials, with flash points:
-
Above 79°C and
-
Below 400°C (excluding fuel oils)
Also used to determine the fire point, i.e., the temperature at which the test specimen sustains combustion for a minimum of 5 seconds.
Aza Lab Dist‑86S (AZA 1288)
AZA-LAB Classic Open Cup Flash Point Apparatus (AZA – 1294)
This Flash Point Tester is designed to accurately determine the flash point of petroleum products using the Cleveland Open Cup method. Ideal for quality control, research labs, and routine testing, it ensures safe and reliable operation.
Dist‑86S Semi‑Automated Distillation Analyzer (AZA 1283)
Standards & Methods
- ASTM D86, D850, D1078
- ISO 3405, IP123, IP195
- JIS K2254, IS 1448 P:18